W DOC AIRBUS | TSM A320F

NLG Doors Do Not Close Fully or Slow to Operate


TASK 32-31-00-810-859-A
NLG Doors Do Not Close Fully or Slow to Operate


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
1. Possible Causes
  • nose gear door-operating mechanism
  • NLG main door control-rod
  • nose-gear door clearances and mismatches
  • NLG door uplock units and pins
  • NLG door hinges
  • UPLOCK ASSY-NLG DOOR [2534GM]
  • ACTG CYL-NLG DOOR [2531GM]
  • RESTRICTOR-NLG DOOR CLOSING [2536GM]
  • BYPASS VALVE-NLG DOOR GROUND OPENING [2533GM]
  • SAFETY VALVE-NLG DOOR CLOSING [2629GM]
  • [41GA]
  • MANIFOLD ASSY-L/G AND DOOR SELECTOR VALVES [2524GM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 32-31-00-810-898-A
L/G - All Landing Gears and all Landing Gear Doors Slow Operation
AMM 32-22-00-010-001
Nose Gear Doors - Ground Doors Opening
AMM 32-22-00-220-001
Check of the Nose-Gear Doors Gaps and Mismatches
AMM 32-22-17-000-001
Removal of the NLG-Door Ground-Opening Control-Unit
AMM 32-22-17-400-001
Installation of the NLG-Door Ground-Opening Control-Unit
AMM 32-30-00-200-001
Detailed Inspection of Nose Gear Door Operating Mechanism
AMM 32-31-00-200-001
Detailed Inspection of Gear Uplock and Door Uplock Units and Rollers
AMM 32-31-00-720-003
Functional Test of the Normal Extension and Retraction of the Nose Landing Gear
AMM 32-31-14-000-001
Removal of the NLG Door Uplock Assy
AMM 32-31-14-400-001
Installation of the NLG Door Uplock Assy
AMM 32-31-16-000-001
Removal of the NLG Door Actuating Cylinder
AMM 32-31-16-400-001
Installation of the NLG Door Actuating Cylinder
AMM 32-31-19-000-001
Removal of the Safety Valves
AMM 32-31-19-400-001
Installation of the Safety Valves
AMM 32-31-31-000-001
Removal of the Selector-Valve Manifold Assembly
AMM 32-31-31-400-001
Installation of the Selector-Valve Manifold Assembly
AMM 32-31-34-000-001
Removal of the Landing-Gear (L/G) Door Selector Valve
AMM 32-31-34-400-001
Installation of the Landing-Gear (L/G) Door Selector Valve
AMM 32-31-41-000-001
Removal of the NLG main door control rod
AMM 32-31-41-400-001
Installation of the NLG main door control rod
AMM 32-31-58-000-001
Removal of the NLG Door Closing Restrictor
AMM 32-31-58-400-001
Installation of the NLG Door Closing Restrictor
AMM 52-82-00-200-001
Detailed Inspection of NLG, Main Door Hinges, LH/RH
3. Fault Confirmation
Subtask 32-31-00-860-091-A
A. Procedure
   (1) Do a check of the post flight report:
  • If there is LGCIU 1 and 2 FAULT ECAM messages and related NLG door-closed target-position CFDS messages
    or
  • If there is a CFDS NLG DOORS DO NOT CLOSED FULLY message shown.
     (a) Do the Fault Isolation procedure.
4. Fault Isolation
Subtask 32-31-00-810-117-A
A. Procedure
   (1) Do the detailed inspection of the nose gear door-operating mechanism AMM 32-30-00-200-001.
   (2) Do a check of the NLG main door control-rod :
     (a) Make sure that the rod length between the eye-end centers is 848 mm (33.3858 in.) plus or minus 0.2 mm (0.0079 in.) AMM 32-31-41-400-001.
     (b) Make sure that the NLG main door control-rod is not damaged. If you find damage, replace it AMM 32-31-41-000-001 and AMM 32-31-41-400-001.
   (3) Do a check of the nose-gear door clearances and mismatches AMM 32-22-00-220-001.
   (4) Do the detailed inspection of the NLG door uplock units and pins AMM 32-31-00-200-001.
   (5) Do the detailed inspection of the NLG door hinges AMM 52-82-00-200-001.
   (6) Correct all the faults that you find.
   (7) Do the functional test of the normal extension and retraction of the NLG AMM 32-31-00-720-003.
   (8) If the NLG doors close in the correct time but do not uplock:
     (a) Replace the UPLOCK ASSY-NLG DOOR [2534GM] AMM 32-31-14-000-001 and AMM 32-31-14-400-001.
   (9) If the fault continues:
     (a) Use the ground-door opening handle and operate the NLG doors 10 times AMM 32-22-00-010-001.
NOTE: This will bleed the door open/close hydraulic system.
   (10) If the fault continues:
     (a) Replace the ACTG CYL-NLG DOOR [2531GM] AMM 32-31-16-000-001 and AMM 32-31-16-400-001.
   (11) If the fault continues:
     (a) Replace the RESTRICTOR-NLG DOOR CLOSING [2536GM] AMM 32-31-58-000-001 and AMM 32-31-58-400-001.
   (12) If the fault continues:
     (a) Replace the BYPASS VALVE-NLG DOOR GROUND OPENING [2533GM] AMM 32-22-17-000-001 and AMM 32-22-17-400-001.
   (13) If the fault continues:
     (a) Replace the SAFETY VALVE-NLG DOOR CLOSING [2629GM] AMM 32-31-19-000-001 and AMM 32-31-19-400-001.
   (14) If the fault continues:
     (a) Replace the [41GA] AMM 32-31-34-000-001 and AMM 32-31-34-400-001.
     (b) Replace the MANIFOLD ASSY-L/G AND DOOR SELECTOR VALVES [2524GM] AMM 32-31-31-000-001 and AMM 32-31-31-400-001.
   (15) If the fault continues:
     (a) Do the TSM task (Ref. TSM TASK 32-31-00-810-898).
5. Close-up
Subtask 32-31-00-942-059-A
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:40:14 UTC