NLG Doors Do Not Close Fully or Slow to Operate
TASK 32-31-00-810-859-A
NLG Doors Do Not Close Fully or Slow to Operate
A. Referenced Information
3. Fault Confirmation
Subtask 32-31-00-860-091-A
Subtask 32-31-00-810-117-A
Subtask 32-31-00-942-059-A
[Rev.8 from Aug 2018]
2026.04.04 04:40:14 UTC
NLG Doors Do Not Close Fully or Slow to Operate
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Possible Causes- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
- nose gear door-operating mechanism
- NLG main door control-rod
- nose-gear door clearances and mismatches
- NLG door uplock units and pins
- NLG door hinges
- UPLOCK ASSY-NLG DOOR [2534GM]
- ACTG CYL-NLG DOOR [2531GM]
- RESTRICTOR-NLG DOOR CLOSING [2536GM]
- BYPASS VALVE-NLG DOOR GROUND OPENING [2533GM]
- SAFETY VALVE-NLG DOOR CLOSING [2629GM]
[41GA] - MANIFOLD ASSY-L/G AND DOOR SELECTOR VALVES [2524GM]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 32-31-00-810-898-A | L/G - All Landing Gears and all Landing Gear Doors Slow Operation |
| AMM 32-22-00-010-001 | Nose Gear Doors - Ground Doors Opening |
| AMM 32-22-00-220-001 | Check of the Nose-Gear Doors Gaps and Mismatches |
| AMM 32-22-17-000-001 | Removal of the NLG-Door Ground-Opening Control-Unit |
| AMM 32-22-17-400-001 | Installation of the NLG-Door Ground-Opening Control-Unit |
| AMM 32-30-00-200-001 | Detailed Inspection of Nose Gear Door Operating Mechanism |
| AMM 32-31-00-200-001 | Detailed Inspection of Gear Uplock and Door Uplock Units and Rollers |
| AMM 32-31-00-720-003 | Functional Test of the Normal Extension and Retraction of the Nose Landing Gear |
| AMM 32-31-14-000-001 | Removal of the NLG Door Uplock Assy |
| AMM 32-31-14-400-001 | Installation of the NLG Door Uplock Assy |
| AMM 32-31-16-000-001 | Removal of the NLG Door Actuating Cylinder |
| AMM 32-31-16-400-001 | Installation of the NLG Door Actuating Cylinder |
| AMM 32-31-19-000-001 | Removal of the Safety Valves |
| AMM 32-31-19-400-001 | Installation of the Safety Valves |
| AMM 32-31-31-000-001 | Removal of the Selector-Valve Manifold Assembly |
| AMM 32-31-31-400-001 | Installation of the Selector-Valve Manifold Assembly |
| AMM 32-31-34-000-001 | Removal of the Landing-Gear (L/G) Door Selector Valve |
| AMM 32-31-34-400-001 | Installation of the Landing-Gear (L/G) Door Selector Valve |
| AMM 32-31-41-000-001 | Removal of the NLG main door control rod |
| AMM 32-31-41-400-001 | Installation of the NLG main door control rod |
| AMM 32-31-58-000-001 | Removal of the NLG Door Closing Restrictor |
| AMM 32-31-58-400-001 | Installation of the NLG Door Closing Restrictor |
| AMM 52-82-00-200-001 | Detailed Inspection of NLG, Main Door Hinges, LH/RH |
Subtask 32-31-00-860-091-A
A. Procedure
(1) Do a check of the post flight report:
4. Fault Isolation(1) Do a check of the post flight report:
- If there is LGCIU 1 and 2 FAULT ECAM messages and related NLG door-closed target-position CFDS messages
or - If there is a CFDS NLG DOORS DO NOT CLOSED FULLY message shown.
Subtask 32-31-00-810-117-A
A. Procedure
(1) Do the detailed inspection of the nose gear door-operating mechanism AMM 32-30-00-200-001.
(2) Do a check of the NLG main door control-rod :
(a) Make sure that the rod length between the eye-end centers is 848 mm (33.3858 in.) plus or minus 0.2 mm (0.0079 in.) AMM 32-31-41-400-001.
(b) Make sure that the NLG main door control-rod is not damaged. If you find damage, replace it AMM 32-31-41-000-001 and AMM 32-31-41-400-001.
(3) Do a check of the nose-gear door clearances and mismatches AMM 32-22-00-220-001.
(4) Do the detailed inspection of the NLG door uplock units and pins AMM 32-31-00-200-001.
(5) Do the detailed inspection of the NLG door hinges AMM 52-82-00-200-001.
(6) Correct all the faults that you find.
(7) Do the functional test of the normal extension and retraction of the NLG AMM 32-31-00-720-003.
(8) If the NLG doors close in the correct time but do not uplock:
(a) Replace the UPLOCK ASSY-NLG DOOR [2534GM] AMM 32-31-14-000-001 and AMM 32-31-14-400-001.
(9) If the fault continues:
(a) Use the ground-door opening handle and operate the NLG doors 10 times AMM 32-22-00-010-001.
(a) Replace the ACTG CYL-NLG DOOR [2531GM] AMM 32-31-16-000-001 and AMM 32-31-16-400-001.
(11) If the fault continues:
(a) Replace the RESTRICTOR-NLG DOOR CLOSING [2536GM] AMM 32-31-58-000-001 and AMM 32-31-58-400-001.
(12) If the fault continues:
(a) Replace the BYPASS VALVE-NLG DOOR GROUND OPENING [2533GM] AMM 32-22-17-000-001 and AMM 32-22-17-400-001.
(13) If the fault continues:
(a) Replace the SAFETY VALVE-NLG DOOR CLOSING [2629GM] AMM 32-31-19-000-001 and AMM 32-31-19-400-001.
(14) If the fault continues:
(a) Replace the [41GA] AMM 32-31-34-000-001 and AMM 32-31-34-400-001.
(b) Replace the MANIFOLD ASSY-L/G AND DOOR SELECTOR VALVES [2524GM] AMM 32-31-31-000-001 and AMM 32-31-31-400-001.
(15) If the fault continues:
(a) Do the TSM task (Ref. TSM TASK 32-31-00-810-898).
5. Close-up(1) Do the detailed inspection of the nose gear door-operating mechanism AMM 32-30-00-200-001.
(2) Do a check of the NLG main door control-rod :
(a) Make sure that the rod length between the eye-end centers is 848 mm (33.3858 in.) plus or minus 0.2 mm (0.0079 in.) AMM 32-31-41-400-001.
(b) Make sure that the NLG main door control-rod is not damaged. If you find damage, replace it AMM 32-31-41-000-001 and AMM 32-31-41-400-001.
(3) Do a check of the nose-gear door clearances and mismatches AMM 32-22-00-220-001.
(4) Do the detailed inspection of the NLG door uplock units and pins AMM 32-31-00-200-001.
(5) Do the detailed inspection of the NLG door hinges AMM 52-82-00-200-001.
(6) Correct all the faults that you find.
(7) Do the functional test of the normal extension and retraction of the NLG AMM 32-31-00-720-003.
(8) If the NLG doors close in the correct time but do not uplock:
(a) Replace the UPLOCK ASSY-NLG DOOR [2534GM] AMM 32-31-14-000-001 and AMM 32-31-14-400-001.
(9) If the fault continues:
(a) Use the ground-door opening handle and operate the NLG doors 10 times AMM 32-22-00-010-001.
NOTE: This will bleed the door open/close hydraulic system.
(10) If the fault continues:(a) Replace the ACTG CYL-NLG DOOR [2531GM] AMM 32-31-16-000-001 and AMM 32-31-16-400-001.
(11) If the fault continues:
(a) Replace the RESTRICTOR-NLG DOOR CLOSING [2536GM] AMM 32-31-58-000-001 and AMM 32-31-58-400-001.
(12) If the fault continues:
(a) Replace the BYPASS VALVE-NLG DOOR GROUND OPENING [2533GM] AMM 32-22-17-000-001 and AMM 32-22-17-400-001.
(13) If the fault continues:
(a) Replace the SAFETY VALVE-NLG DOOR CLOSING [2629GM] AMM 32-31-19-000-001 and AMM 32-31-19-400-001.
(14) If the fault continues:
(a) Replace the
(b) Replace the MANIFOLD ASSY-L/G AND DOOR SELECTOR VALVES [2524GM] AMM 32-31-31-000-001 and AMM 32-31-31-400-001.
(15) If the fault continues:
(a) Do the TSM task (Ref. TSM TASK 32-31-00-810-898).
Subtask 32-31-00-942-059-A
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(1) Make sure that the work area is clean and clear of tools and other items.