W DOC AIRBUS | TSM A320F

Loss of the FQI Output Buses by the DMC3


TASK 31-63-81-810-930-A
Loss of the FQI Output Buses by the DMC3


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 28-42-00-810-801-A
Fuel Quantity Indication Computer (FQIC) 3QT
TSM TASK 31-63-00-810-920-A
Loss of the FQI 1 Output Bus by the DMC 3
TSM TASK 31-63-00-810-921-A
Loss of the FQI 2 Output Bus by the DMC 3
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
3. Fault Confirmation
Subtask 31-63-81-740-304-A ** ON A/C NOT FOR ALL
A. Test
Do the ground scanning test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 31-63-81-810-212-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message FQI(3QT):
   (1) If the fault continues:
Subtask 31-63-81-740-305-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:31:06 UTC