Loss of the FQI 1 Output Bus by the DMC 3
TASK 31-63-00-810-920-A
Loss of the FQI 1 Output Bus by the DMC 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-865-152-A
Subtask 31-63-00-810-168-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:46 UTC
Loss of the FQI 1 Output Bus by the DMC 3
1. Possible Causes
- DMC-3 [1WT3]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 28-42-00-740-007 | Interrogation of the (SMITHS INDUSTRIES) FQIS Trouble Shooting Data |
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| ASM 316201 | |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-00-865-152-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-63-00-740-250-A ** ON A/C NOT FOR ALL Subtask 31-63-00-740-250-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
Subtask 31-63-00-810-168-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 3 : NO FQI 1 DATA:
Subtask 31-63-00-810-168-B ** ON A/C NOT FOR ALL - replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the DMC 3 (1WT3) pins AA/11A, 11B to the first terminal block ASM 316201.
A. If the test gives the maintenance message FQI(3QT)BUS1/DMC3(1WT3):
Subtask 31-63-00-740-251-A - replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- Do the interrogation of the (SMITHS INDUSTRIES) FQIS Trouble Shooting Data AMM 28-42-00-740-007.
- do a check and repair the wiring from the DMC 3 (1WT3) pins AD/9J, 9K to the first terminal block ASM 316201.
B. Do the test given in Para. 3.B.