Loss of the FCU 2 Output Buses by the DMC 2
TASK 31-63-00-810-998-A
Loss of the FCU 2 Output Buses by the DMC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-740-396-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-251-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:53 UTC
Loss of the FCU 2 Output Buses by the DMC 2
1. Possible Causes
- FCU [2CA]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-63-00-810-896-A | Loss of the FCU 2 Channel A Output Bus by the DMC 2 |
| TSM TASK 31-63-00-810-897-A | Loss of the FCU 2 Channel B Output Bus by the DMC 2 |
| AMM 22-81-12-000-001 | Removal of the FCU |
| AMM 22-81-12-400-001 | Installation of the FCU |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
Subtask 31-63-00-740-396-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-251-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message FCU2(2CA)/DMC2(1WT2):
Subtask 31-63-00-740-397-A ** ON A/C NOT FOR ALL - Do the fault isolation (Para. 4. A.) of the procedures (Ref. TSM TASK 31-63-00-810-896) and (Ref. TSM TASK 31-63-00-810-897)
- replace the FCU [2CA] AMM 22-81-12-000-001 and AMM 22-81-12-400-001
B. Do the test given in Para. 3.A.