Loss of the FCU 2 Channel B Output Bus by the DMC 2
TASK 31-63-00-810-897-A
Loss of the FCU 2 Channel B Output Bus by the DMC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-865-129-A
Subtask 31-63-00-810-145-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:44 UTC
Loss of the FCU 2 Channel B Output Bus by the DMC 2
1. Possible Causes
- DMC-2 [1WT2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| ASM 316201 | |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-00-865-129-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-63-00-740-204-A ** ON A/C NOT FOR ALL Subtask 31-63-00-740-204-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | AUTO FLT/FCU/2 | 9CA2 | M21 |
Subtask 31-63-00-810-145-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 2 : NO FCU 2B DATA:
Subtask 31-63-00-810-145-C ** ON A/C NOT FOR ALL - replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the DMC 2 (1WT2) pins AA/2F, 2G to the first terminal block ASM 316201.
A. If the test gives the maintenance message FCU2(2CA)BUS FCU2B/DMC2(1WT2):
Subtask 31-63-00-740-205-A - replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the DMC 2 (1WT2) pins AA/1G, 1H to the first terminal block ASM 316201.
B. Do the test given in Para. 3.B.