Ice Formation in the Potable Water Lines
TASK 30-73-00-810-801-A
Ice Formation in the Potable Water Lines
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 30-73-00-710-050-A 4. Fault Isolation
Subtask 30-73-00-810-050-A ** ON A/C NOT FOR ALL
Subtask 30-73-00-860-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:47 UTC
Ice Formation in the Potable Water Lines
1. Possible Causes
- CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW]
HEATER ELEMENT(s) - SENSOR,TEMPERATURE- [10DW]
- microfuse
- aircraft wiring
- CONTROL UNIT, POTABLE WATERICE PROTECTION- [23DW]
HEATER(s) - SENSOR,TEMPERATURE- [29DW]
- SENSOR,TEMPERATURE- [30DW]
- CONTROL UNIT, POTABLE WATERICE PROTECTION- [33DW]
- SENSOR,TEMPERATURE- [40DW]
- CONTROL UNIT, POTABLE WATERICE PROTECTION- [53DW]
- SENSOR,TEMPERATURE- [60DW]
- SENSOR,TEMPERATURE- [61DW]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 30-71-00-810-805-A | Failure of FWD Waste-Water Ice-Protection System |
| AMM 30-73-00-720-001 | Functional Test of the Potable Water Ice-Protection |
| AMM 30-73-00-740-001 | BITE Test of the Potable Water Ice-Protection |
| ASM 307301 | |
| ASM 307302 | |
| AMM 30-73-17-000-001 | Removal of the Potable-Water De-icing Sensor |
| AMM 30-73-17-400-001 | Installation of the Potable-Water De-icing Sensor |
| AMM 30-73-18-000-001 | Removal of the Potable Water De-icing Sensor |
| AMM 30-73-18-400-001 | Installation of the Potable Water De-icing Sensor |
| AMM 30-73-19-000-001 | Removal of Temperature Sensor 30DW |
| AMM 30-73-19-400-001 | Installation of Temperature Sensor 30DW |
| AMM 30-73-34-000-001 | Removal of the Potable and Waste Water Ice Protection Control Unit |
| AMM 30-73-34-000-002 | Removal of the Potable and Waste Water Ice Protection Contol Unit and of the Potable Water Ice Protection Control Unit |
| AMM 30-73-34-400-001 | Installation of the Potable and Waste Water Ice Protection Control Unit |
| AMM 30-73-34-400-002 | Installation of the Potable and Waste water Ice Protection Control Unit and of the Potable Water Ice Protection Control Unit |
| AMM 30-73-35-000-001 | Removal of the Potable-Water Ice-Protection Control-Unit 33DW |
| AMM 30-73-35-400-001 | Installation of the Potable-Water Ice-Protection Control-Unit 33DW |
| AMM 30-73-53-000-001 | Removal of the Potable-Water De-icing Heater Elements |
| AMM 30-73-53-400-001 | Installation of the Potable-Water De-icing Heater Elements |
| AMM 30-73-54-000-001 | Removal of the Inner Line Heater |
| AMM 30-73-54-400-001 | Installation of the Inner Line Heater |
| AMM 30-73-55-000-001 | Removal of the Potable-Water Heater Elements |
| AMM 30-73-55-400-001 | Installation of the Potable-Water Heater Elements |
Subtask 30-73-00-710-050-A 4. Fault Isolation
Subtask 30-73-00-810-050-A ** ON A/C NOT FOR ALL
A. Maintenance Action for CONTROL UNIT 3DW
(1) If the green I/II LED of CONTROL UNIT 3DW does not come on:
Do a check of the related microfuses:
(a) If the microfuses are OK:
Replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW] AMM 30-73-34-000-001 and AMM 30-73-34-400-001.
1 If the fault continues:
Do the functional test of the potable-water ice-protection AMM 30-73-00-720-001 and replace the relatedHEATER ELEMENT(s) which stay(s) cold AMM 30-73-53-000-001 and AMM 30-73-53-400-001.
a If all applicable HEATER ELEMENTs stay cold:
Replace the SENSOR,TEMPERATURE- [10DW] AMM 30-73-17-000-001 and AMM 30-73-17-400-001.
(b) If one microfuse is not OK:
Do a check for a short circuit and replace the microfuse ASM 307301.
(2) If the green III/IV LED of the CONTROL UNIT 3DW does not come on:
Do the trouble shooting of the forward waste-water ice-protection system (Ref. TSM TASK 30-71-00-810-805)
(3) If both green LEDs do not come on:
Replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW] AMM 30-73-34-000-001 and AMM 30-73-34-400-001.
(a) If the fault continues:
Do a check of the subsequent signals:
- 115VAC at connector 3DW-A/14,
- 28VDC at connector 3DW-A/16,
- GND at connector 3DW-A/12,
- GND at connector 3DW-A/15 ASM 307301.
1 If one signal is missing:
Do a check and repair of the aircraft wiring ASM 307301.
Subtask 30-73-00-810-050-E ** ON A/C NOT FOR ALL (1) If the green I/II LED of CONTROL UNIT 3DW does not come on:
Do a check of the related microfuses:
(a) If the microfuses are OK:
Replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW] AMM 30-73-34-000-001 and AMM 30-73-34-400-001.
1 If the fault continues:
Do the functional test of the potable-water ice-protection AMM 30-73-00-720-001 and replace the related
a If all applicable HEATER ELEMENTs stay cold:
Replace the SENSOR,TEMPERATURE- [10DW] AMM 30-73-17-000-001 and AMM 30-73-17-400-001.
(b) If one microfuse is not OK:
Do a check for a short circuit and replace the microfuse ASM 307301.
(2) If the green III/IV LED of the CONTROL UNIT 3DW does not come on:
Do the trouble shooting of the forward waste-water ice-protection system (Ref. TSM TASK 30-71-00-810-805)
(3) If both green LEDs do not come on:
Replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW] AMM 30-73-34-000-001 and AMM 30-73-34-400-001.
(a) If the fault continues:
Do a check of the subsequent signals:
- 115VAC at connector 3DW-A/14,
- 28VDC at connector 3DW-A/16,
- GND at connector 3DW-A/12,
- GND at connector 3DW-A/15 ASM 307301.
1 If one signal is missing:
Do a check and repair of the aircraft wiring ASM 307301.
A. Maintenance Action for CONTROL UNIT 3DW
(1) If the green I/II LED of CONTROL UNIT 3DW does not come on:
Do a check of the related microfuses:
(a) If the microfuses are OK:
Replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW] AMM 30-73-34-000-002 and AMM 30-73-34-400-002.
1 If the fault continues:
Do the functional test of the potable-water ice-protection AMM 30-73-00-720-001 and replace the relatedHEATER ELEMENT(s) which stay(s) cold AMM 30-73-53-000-001 and AMM 30-73-53-400-001.
a If all applicable HEATER ELEMENTs stay cold:
Replace the SENSOR,TEMPERATURE- [10DW] AMM 30-73-17-000-001 and AMM 30-73-17-400-001.
(b) If one microfuse is not OK:
Do a check for a short circuit and replace the microfuse ASM 307301.
(2) If the green III/IV LED of the CONTROL UNIT 3DW does not come on:
Do the trouble shooting of the forward waste-water ice-protection system (Ref. TSM TASK 30-71-00-810-805)
(3) If both green LEDs do not come on:
Replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW] AMM 30-73-34-000-002 and AMM 30-73-34-400-002.
(a) If the fault continues:
Do a check of the subsequent signals:
- 115VAC at connector 3DW-A/14,
- 28VDC at connector 3DW-A/16,
- GND at connector 3DW-A/12,
- GND at connector 3DW-A/15 ASM 307301.
1 If one signal is missing:
Do a check and repair of the aircraft wiring ASM 307301.
Subtask 30-73-00-810-051-A ** ON A/C NOT FOR ALL (1) If the green I/II LED of CONTROL UNIT 3DW does not come on:
Do a check of the related microfuses:
(a) If the microfuses are OK:
Replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW] AMM 30-73-34-000-002 and AMM 30-73-34-400-002.
1 If the fault continues:
Do the functional test of the potable-water ice-protection AMM 30-73-00-720-001 and replace the related
a If all applicable HEATER ELEMENTs stay cold:
Replace the SENSOR,TEMPERATURE- [10DW] AMM 30-73-17-000-001 and AMM 30-73-17-400-001.
(b) If one microfuse is not OK:
Do a check for a short circuit and replace the microfuse ASM 307301.
(2) If the green III/IV LED of the CONTROL UNIT 3DW does not come on:
Do the trouble shooting of the forward waste-water ice-protection system (Ref. TSM TASK 30-71-00-810-805)
(3) If both green LEDs do not come on:
Replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW] AMM 30-73-34-000-002 and AMM 30-73-34-400-002.
(a) If the fault continues:
Do a check of the subsequent signals:
- 115VAC at connector 3DW-A/14,
- 28VDC at connector 3DW-A/16,
- GND at connector 3DW-A/12,
- GND at connector 3DW-A/15 ASM 307301.
1 If one signal is missing:
Do a check and repair of the aircraft wiring ASM 307301.
B. Maintenance Action for CONTROL UNIT 23DW
(1) If the green I/II LED of CONTROL UNIT 23DW does not come on:
Subtask 30-73-00-810-052-A ** ON A/C NOT FOR ALL (1) If the green I/II LED of CONTROL UNIT 23DW does not come on:
- do a check of the related microfuses:
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [23DW] AMM 30-73-34-000-001 and AMM 30-73-34-400-001.
- do the functional test of the potable water ice protection AMM 30-73-00-720-001 and replace the related
HEATER(s) which stay(s) cold AMM 30-73-54-000-001 and AMM 30-73-54-400-001 or AMM 30-73-55-000-001 and AMM 30-73-55-400-001.
- replace the SENSOR,TEMPERATURE- [29DW] AMM 30-73-18-000-001 and AMM 30-73-18-400-001.
- do a check for a short circuit and replace the microfuse ASM 307301.
- do a check of the related microfuses:
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [23DW] AMM 30-73-34-000-001 and AMM 30-73-34-400-001.
- do the functional test of the potable water ice protection AMM 30-73-00-720-001 and replace the related
HEATER(s) which stay(s) cold AMM 30-73-55-000-001 and AMM 30-73-55-400-001.
- replace the SENSOR,TEMPERATURE- [30DW] AMM 30-73-19-000-001 and AMM 30-73-19-400-001.
- do a check for a short circuit and replace the microfuse ASM 307301.
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [23DW] AMM 30-73-34-000-001 and AMM 30-73-34-400-001.
- do a check of the subsequent signals:
- 115VAC at connector 23DW-A/14,
- 28VDC at connector 23DW-A/16,
- GND at connector 23DW-A/12,
- GND at connector 23DW-A/15 ASM 307301.
- do a check and repair of the aircraft wiring ASM 307301.
C. Maintenance Action for CONTROL UNIT 33DW
(1) If the green I/II LED of the CONTROL UNIT 33DW does not come on:
Subtask 30-73-00-810-051-E ** ON A/C NOT FOR ALL (1) If the green I/II LED of the CONTROL UNIT 33DW does not come on:
- do the trouble shooting of the FWD waste-water ice-protection system (Ref. TSM TASK 30-71-00-810-805)
- do a check of the related microfuses:
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [33DW] AMM 30-73-35-000-001 and AMM 30-73-35-400-001.
- do the functional test of the potable water ice protection AMM 30-73-00-720-001 and replace the related
HEATER(s) which stay(s) cold AMM 30-73-55-000-001 and AMM 30-73-55-400-001.
- replace the SENSOR,TEMPERATURE- [40DW] AMM 30-73-19-000-001 and AMM 30-73-19-400-001.
- do a check for a short circuit and replace the microfuse ASM 307302.
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [33DW] AMM 30-73-35-000-001 and AMM 30-73-35-400-001.
- do a check of the subsequent signals:
- 115VAC at connector 33DW-A/14,
- 28VDC at connector 33DW-A/16,
- GND at connector 33DW-A/12,
- GND at connector 33DW-A/15 ASM 307302.
- do a check and repair of the aircraft wiring ASM 307302.
D. Maintenance Action for CONTROL UNIT 23DW
(1) If the green I/II LED of CONTROL UNIT 23DW does not come on:
Subtask 30-73-00-810-052-F ** ON A/C NOT FOR ALL (1) If the green I/II LED of CONTROL UNIT 23DW does not come on:
- do a check of the related microfuses:
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [23DW] AMM 30-73-34-000-002 and AMM 30-73-34-400-002.
- do the functional test of the potable water ice protection AMM 30-73-00-720-001 and replace the related
HEATER(s) which stay(s) cold AMM 30-73-54-000-001 and AMM 30-73-54-400-001 or AMM 30-73-55-000-001 and AMM 30-73-55-400-001.
- replace the SENSOR,TEMPERATURE- [29DW] AMM 30-73-18-000-001 and AMM 30-73-18-400-001.
- do a check for a short circuit and replace the microfuse ASM 307301.
- do a check of the related microfuses:
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [23DW] AMM 30-73-34-000-002 and AMM 30-73-34-400-002.
- do the functional test of the potable water ice protection AMM 30-73-00-720-001 and replace the related
HEATER(s) which stay(s) cold AMM 30-73-55-000-001 and AMM 30-73-55-400-001.
- replace the SENSOR,TEMPERATURE- [30DW] AMM 30-73-19-000-001 and AMM 30-73-19-400-001.
- do a check for a short circuit and replace the microfuse ASM 307301.
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [23DW] AMM 30-73-34-000-002 and AMM 30-73-34-400-002.
- do a check of the subsequent signals:
- 115VAC at connector 23DW-A/14,
- 28VDC at connector 23DW-A/16,
- GND at connector 23DW-A/12,
- GND at connector 23DW-A/15 ASM 307301.
- do a check and repair of the aircraft wiring ASM 307301.
E. Maintenance Action for CONTROL UNIT 33DW
(1) If the green I/II LED of CONTROL UNIT 33DW does not come on:
Subtask 30-73-00-810-053-A ** ON A/C NOT FOR ALL (1) If the green I/II LED of CONTROL UNIT 33DW does not come on:
- Do a check of the related microfuses:
- Replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [33DW] AMM 30-73-35-000-001 and AMM 30-73-35-400-001.
- Do the functional test of the potable water ice protection AMM 30-73-00-720-001 and replace the related
HEATER(s) which stay(s) cold AMM 30-73-55-000-001 and AMM 30-73-55-400-001.
- Replace the SENSOR,TEMPERATURE- [40DW] AMM 30-73-19-000-001 and AMM 30-73-19-400-001.
- Do a check for a short circuit and replace the microfuse ASM 307302.
- Replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [33DW] AMM 30-73-35-000-001 and AMM 30-73-35-400-001.
- Do a check of the signals that follow:
- 115VAC at connector 33DW-A/14,
- 28VDC at connector 33DW-A/16,
- GND at connector 33DW-A/12,
- GND at connector 33DW-A/15 ASM 307302.
- Do a check and repair of the aircraft wiring ASM 307302.
F. Maintenance Action for CONTROL UNIT 53DW
(1) If the green I/II LED of CONTROL UNIT 53DW does not come on:
Subtask 30-73-00-710-051-A (1) If the green I/II LED of CONTROL UNIT 53DW does not come on:
- do a check of the related microfuses:
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [53DW] AMM 30-73-35-000-001 and AMM 30-73-35-400-001.
- do the functional test of the potable water ice protection AMM 30-73-00-720-001 and replace the related
HEATER(s) which stay(s) cold AMM 30-73-55-000-001 and AMM 30-73-55-400-001.
- replace the SENSOR,TEMPERATURE- [60DW] AMM 30-73-19-000-001 and AMM 30-73-19-400-001.
- do a check for a short circuit and replace the microfuse ASM 307302.
- do a check of the related microfuses:
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [53DW] AMM 30-73-35-000-001 and AMM 30-73-35-400-001.
- do the functional test of the potable water ice protection AMM 30-73-00-720-001 and replace the related
HEATER(s) which stay(s) cold AMM 30-73-55-000-001 and AMM 30-73-55-400-001.
- replace the SENSOR,TEMPERATURE- [61DW] AMM 30-73-19-000-001 and AMM 30-73-19-400-001.
- do a check for a short circuit and replace the microfuse ASM 307302.
- replace the CONTROL UNIT, POTABLE WATERICE PROTECTION- [53DW] AMM 30-73-35-000-001 and AMM 30-73-35-400-001.
- do a check of the subsequent signals:
- 115VAC at connector 53DW-A/14,
- 28VDC at connector 53DW-A/16,
- GND at connector 53DW-A/12,
- GND at connector 53DW-A/15 ASM 307302.
- do a check and repair of the aircraft wiring ASM 307302.
G. Do the test as given in the Para. 3.A.
5. Close-upSubtask 30-73-00-860-050-A
A. Put the aircraft back to its initial configuration.