Failure of FWD Waste-Water Ice-Protection System


TASK 30-71-00-810-805-A
Failure of FWD Waste-Water Ice-Protection System


1. Possible Causes
  • CONTROL UNIT, WASTE WATER ICE PROTECTION- [5DU]
  • DRAINMAST "F" [4DU]
  • wiring
  • CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW]
  • SENSOR,TEMPERATURE- [40DU]
  • HEATER-ELEMENT WASTE-WATER DE-ICING (41DU)
  • HEATER-TAPE, [42DU]
  • microfuse
  • CONTROL UNIT, WASTE WATER ICE PROTECTION- [140DU]
  • SENSOR,TEMPERATURE- [141DU]
  • HEATER ELEMENT-WASTE WATER DE ICING (142DU)
  • HEATER ELEMENT-WASTE WATER DE ICING (146DU)
  • HEATER ELEMENT-WASTE WATER DE ICING (147DU)
  • HEATER [48DU]
  • HEATER [49DU]
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
SPRAY - COOLING
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 30-71-00-710-002
Operational Test of the Waste-Water Ice-Protection Heater-Elements
AMM 30-71-00-740-001
BITE Test of the Drainmast Ice Protection (through CIDS SYSTEM/TEST)
ASM 307101
AMM 30-71-17-000-001
Removal of the Waste-Water De-icing Sensor
AMM 30-71-17-400-001
Installation of the Waste-Water De-icing Sensor
AMM 30-71-34-000-001
Removal of the Waste-Water Ice-Protection Control-Unit
AMM 30-71-34-400-001
Installation of the Waste-Water Ice-Protection Control-Unit
AMM 30-71-51-000-001
Removal of the Drain Mast
AMM 30-71-51-400-001
Installation of the Drain Mast
AMM 30-71-53-000-001
Removal of the Waste-Water De-icing Heater Elements
AMM 30-71-53-000-003
Removal of the Waste-Water De-icing Heater Elements
AMM 30-71-53-400-001
Installation of the Waste-Water De-icing Heater Elements
AMM 30-71-53-400-003
Installation of the Waste-Water De-icing Heater Elements
AMM 30-73-00-740-001
BITE Test of the Potable Water Ice-Protection
AMM 30-73-34-000-001
Removal of the Potable and Waste Water Ice Protection Control Unit
AMM 30-73-34-400-001
Installation of the Potable and Waste Water Ice Protection Control Unit
3. Fault Confirmation
Subtask 30-71-00-710-058-A ** ON A/C NOT FOR ALL
A. Do the operational test of the waste-water ice-protection system AMM 30-71-00-710-002.
Subtask 30-71-00-710-058-B ** ON A/C NOT FOR ALL
A. Do the BITE Test of the Drainmast Ice Protection (via CIDS System/Test) AMM 30-71-00-740-001
4. Fault Isolation
Subtask 30-71-00-810-055-A
A. If the green 'UNIT' LED of the CONTROL UNIT 5DU does not come on:
Replace the CONTROL UNIT, WASTE WATER ICE PROTECTION- [5DU] AMM 30-71-34-000-001 and AMM 30-71-34-400-001.
Subtask 30-71-00-810-056-A
B. If the green HTR LED of CONTROL UNIT 5DU does not come on:
   (1) Do a check of the resistance value of the drainmast heater and the temperature sensor. Refer to the resistance values in the tables.
  • Resistance of value the temperature sensor:
TEMPERATURE
RESISTANCE VALUE IN OHM
-10deg C (14deg F)
1784+-9
0deg C (32deg F)
1854+-8
+10deg C (50deg F)
1926+-6
+20deg C (68deg F)
2000+-5
+30deg C (86deg F)
2076+-5
+40deg C (104deg F)
2153+-6

  • Resistance value of the heater:
PART NUMBER
RESISTANCE VALUE IN OHM
4-60000H800-00
57+-3
4-60000H840-00
57+-3
4-60000H880-00
118+-5
4-60000H882-00
118+-5
4-60000H883-00
118+-5

   (2) If the fault continues:
     (a) Replace DRAINMAST "F" [4DU] or only the cover or the heater tube assembly AMM 30-71-51-000-001 and AMM 30-71-51-400-001.
   (3) If the fault continues:
     (a) Do a check and repair the wiring between:
  • CONTROL UNIT 5DU connector A/4 and DRAINMAST 4DU connector A/D
  • CONTROL UNIT 5DU connector A/5 and DRAINMAST 4DU connector A/E
  • CONTROL UNIT 5DU connector A/8 and DRAINMAST 4DU connector A/B
  • DRAINMAST 4DU connector A/C and GND
  • DRAINMAST 4DU connector A/A and GND ASM 307101.
Subtask 30-71-00-810-058-A
C. If the green 'UNIT' LED and the green 'HTR' LED of the CONTROL UNIT 5DU do not come on:
Do a check for the subsequent signals:
  • 115 VAC at CONTROL UNIT 5DU connector A/14,
  • GND at CONTROL UNIT 5DU connector A/15 ASM 307101.
   (1) If the two signals are OK:
Replace the CONTROL UNIT, WASTE WATER ICE PROTECTION- [5DU] AMM 30-71-34-000-001 and AMM 30-71-34-400-001.
   (2) If there is no GND:
Do a check and repair the wiring between CONTROL UNIT 5DU connector A/15 and GND ASM 307101.
   (3) If there is no 115 VAC:
Do a check and repair the wiring between CONTROL UNIT 5DU connector A/14 and CB 1DU ASM 307101.
Subtask 30-71-00-810-057-A ** ON A/C NOT FOR ALL
D. If the green UNIT LED and the green HTR LED of CONTROL UNIT 5DU come on:
   (1) Do the BITE test of the potable-water ice-protection system AMM 30-73-00-740-001.
   (2) If the green III/IV LED of CONTROL UNIT 3DW does not come on:
     (a) Do a check of the related microfuses.
     (b) If the microfuses are OK:
       1 Replace CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW] AMM 30-73-34-000-001 and AMM 30-73-34-400-001.
     (c) If the fault continues:
       1 Remove the insulation from around the SENSOR 40DU, HEATER 42DU and HEATER 41DU.
       2 Apply SPRAY - COOLING to the SENSOR 40DU for at least 10 s.
       3 Stop for approximately 120 s.
       4 Do a check of the temperature of HEATER 42DU and HEATER 41DU.
       5 If a heater stays cold:
         a Do a check of the resistance value of the drainmast heater and the temperature sensor. Refer to the resistance values in the tables.
  • Resistance values of the temperature sensor:
TEMPERATURE
RESISTANCE VALUE IN OHM
-10deg C (14deg F)
1784+-9
0deg C (32deg F)
1854+-8
+10deg C (50deg F)
1926+-6
+20deg C (68deg F)
2000+-5
+30deg C (86deg F)
2076+-5
+40deg C (104deg F)
2153+-6

  • Resistance values of the heater:
PART NUMBER
RESISTANCE VALUE IN OHM
4-60000H800-00
57+-3
4-60000H840-00
57+-3
4-60000H880-00
118+-5
4-60000H882-00
118+-5
4-60000H883-00
118+-5

     (d) If the fault continues:
       1 If HEATER 42DU and HEATER 41DU stay cold:
Replace SENSOR,TEMPERATURE- [40DU] AMM 30-71-17-000-001 and AMM 30-71-17-400-001.
       2 If HEATER 41DU stays cold:
Replace HEATER-ELEMENT WASTE-WATER DE-ICING (41DU) AMM 30-71-53-000-001 and AMM 30-71-53-400-001.
       3 If HEATER 42DU stays cold:
Replace HEATER-TAPE, [42DU] AMM 30-71-53-000-001 and AMM 30-71-53-400-001.
     (e) If one microfuse is not OK:
       1 Do a check for a short circuit ASM 307101.
       2 Replace the microfuse .
Subtask 30-71-00-810-057-B ** ON A/C NOT FOR ALL
D. If the green I/II LED of CONTROL UNIT 140DU does not come on:
   (1) Do a check of the related microfuses.
   (2) If the microfuses are OK:
     (a) Replace the CONTROL UNIT, WASTE WATER ICE PROTECTION- [140DU] AMM 30-71-34-000-001 and AMM 30-71-34-400-001.
   (3) If the fault continues:
     (a) Do a check for the subsequent signals:
  • 115 VAC at CONTROL UNIT 140DU connector A/14
  • 28 VDC at CONTROL UNIT 140DU connector A/16
  • GND at CONTROL UNIT 140DU connector A/12
  • GND at CONTROL UNIT 140DU connector A/15 ASM 307101.
     (b) If all the signals are OK:
       1 Remove the insulation from around SENSOR 141DU, the HEATERS 142DU, 146DU and 147DU.
       2 Apply SPRAY - COOLING to the SENSOR 141DU for at least 10 s.
       3 Stop for approximately 120 s.
       4 Do a check of the temperature of the HEATERS 142DU, 146DU and 147DU.
       5 If one of the HEATERS stays cold:
         a Do a check of the resistance value of the drainmast heater and the temperature sensor. Refer to the resistance values in the tables.
  • Resistance values of the temperature sensor:
TEMPERATURE
RESISTANCE VALUE IN OHM
-10deg C (14deg F)
1784+-9
0deg C (32deg F)
1854+-8
+10deg C (50deg F)
1926+-6
+20deg C (68deg F)
2000+-5
+30deg C (86deg F)
2076+-5
+40deg C (104deg F)
2153+-6

  • Resistance values of the heater:
PART NUMBER
RESISTANCE VALUE IN OHM
4-60000H800-00
57+-3
4-60000H840-00
57+-3
4-60000H880-00
118+-5
4-60000H882-00
118+-5
4-60000H883-00
118+-5

     (c) If the fault continues:
       1 If the HEATERS 142DU, 146DU and 147DU stay cold:
Replace SENSOR,TEMPERATURE- [141DU] AMM 30-71-17-000-001 and AMM 30-71-17-400-001.
       2 If HEATER 142DU stays cold:
Replace HEATER ELEMENT-WASTE WATER DE ICING (142DU) AMM 30-71-53-000-003 and AMM 30-71-53-400-003.
       3 If HEATER 146DU stays cold:
Replace HEATER ELEMENT-WASTE WATER DE ICING (146DU) AMM 30-71-53-000-003 and AMM 30-71-53-400-003.
       4 If HEATER 147DU stays cold:
Replace HEATER ELEMENT-WASTE WATER DE ICING (147DU) AMM 30-71-53-000-003 and AMM 30-71-53-400-003.
     (d) If there is no 115 VAC:
       1 Do a check and repair the wiring between:
CONTROL UNIT 140DU connector A/14 and CB 8DU.
     (e) If there is no 28 VDC:
       1 Do a check and repair the wiring between:
CONTROL UNIT 140DU connector A/16 and CB 9DU.
     (f) If there is no GND:
       1 Do a check and repair the related wiring between:
  • CONTROL UNIT 140DU connector A/12 and GND
  • CONTROL UNIT 140DU connector A/15 and GND ASM 307101.
   (4) If one microfuse is not OK:
     (a) Do a check for a short circuit ASM 307101.
     (b) Replace the microfuse.
Subtask 30-71-00-810-057-D ** ON A/C NOT FOR ALL
D. If the green UNIT LED and the green HTR LED of CONTROL UNIT 5DU come on:
   (1) Do the BITE test of the potable-water ice-protection system AMM 30-73-00-740-001.
   (2) If the green III/IV LED of CONTROL UNIT 3DW does not come on:
     (a) Do a check of the related microfuses.
     (b) If the microfuses are OK:
       1 Replace CONTROL UNIT, POTABLE WATERICE PROTECTION- [3DW] AMM 30-73-34-000-001 and AMM 30-73-34-400-001.
     (c) If the fault continues:
       1 Remove the insulation from around the SENSOR 141DU, the HEATER 48DU,HEATER 49DU and HEATER 142DU.
       2 Apply SPRAY - COOLING to the SENSOR 141DU for at least 10 s.
       3 Stop for approximately 120 s.
       4 Do a check of the temperature of HEATER 48DU, HEATER 49DU and HEATER 142DU.
       5 If one of the HEATERS stays cold:
         a Do a check of the resistance value of the drainmast heater and the temperature sensor. Refer to the resistance values in the tables.
  • Resistance values of the temperature sensor:
TEMPERATURE
RESISTANCE VALUE IN OHM
-10deg C (14deg F)
1784+-9
0deg C (32deg F)
1854+-8
+10deg C (50deg F)
1926+-6
+20deg C (68deg F)
2000+-5
+30deg C (86deg F)
2076+-5
+40deg C (104deg F)
2153+-6

  • Resistance values of the heater:
PART NUMBER
RESISTANCE VALUE IN OHM
4-60000H800-00
57+-3
4-60000H840-00
57+-3
4-60000H880-00
118+-5
4-60000H882-00
118+-5
4-60000H883-00
118+-5

     (d) If the fault continues:
       1 If HEATER 48DU, HEATER 49DU and HEATER 142DU stay cold:
       2 If HEATER 48DU stays cold:
       3 If HEATER 49DU stays cold:
       4 If HEATER 142DU stays cold:
     (e) If one microfuse is not OK:
  • Do a check for a short circuit ASM 307101.
  • Replace the microfuse .
Subtask 30-71-00-710-059-A
E. Do the test as given in Para. 3.A.
5. Close-up
Subtask 30-71-00-860-054-A
A. Put the aircraft back to its initial configuration.