W DOC AIRBUS | TSM A320F

FWD Drainmast-Heater Failure


TASK 30-71-00-810-801-A
FWD Drainmast-Heater Failure


1. Possible Causes
  • CONTROL UNIT, WASTE WATER ICE PROTECTION- [5DU]
  • DRAINMAST "F" [4DU]
  • wiring
  • DEU-B [300RH1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 23-73-00-810-827-A
DEU-B - Fault in DEU-B 300RHx with connected systems/devices
AMM 23-73-47-000-001
Removal of the Decoder/Encoder Unit B (300RH)
AMM 23-73-47-400-001
Installation of the Decoder/Encoder Unit B (300RH)
AMM 30-71-00-710-001
Operational Test of the Drainmast Ice Protection
AMM 30-71-00-740-001
BITE Test of the Drainmast Ice Protection (through CIDS SYSTEM/TEST)
ASM 307101
AMM 30-71-34-000-001
Removal of the Waste-Water Ice-Protection Control-Unit
AMM 30-71-34-400-001
Installation of the Waste-Water Ice-Protection Control-Unit
AMM 30-71-51-000-001
Removal of the Drain Mast
AMM 30-71-51-400-001
Installation of the Drain Mast
3. Fault Confirmation
Subtask 30-71-00-710-050-A ** ON A/C NOT FOR ALL
A. Do the operational test of the waste-water ice-protection system AMM 30-71-00-710-001.
Subtask 30-71-00-710-050-B ** ON A/C NOT FOR ALL
A. Do the BITE Test of the Drainmast Ice Protection (via CIDS System/Test) AMM 30-71-00-740-001
4. Fault Isolation
Subtask 30-71-00-810-050-A ** ON A/C NOT FOR ALL
A. If the PTP 110RH shows the fault message DRAINMASTS HEATER FWD
   (1) If the green HTR LED of CONTROL UNIT 5DU does not come on:
     (a) Replace CONTROL UNIT, WASTE WATER ICE PROTECTION- [5DU] AMM 30-71-34-000-001 and AMM 30-71-34-400-001.
     (b) If the fault continues:
       1 Do a check of the resistance value of the drainmast heater and the temperature sensor. Refer to the resistance values in the tables.
  • Resistance values of the temperature sensor:
TEMPERATURE
RESISTANCE VALUE IN OHM
-10deg C (14deg F)
1784+-9
0deg C (32deg F)
1854+-8
+10deg C (50deg F)
1926+-6
+20deg C (68deg F)
2000+-5
+30deg C (86deg F)
2076+-5
+40deg C (104deg F)
2153+-6

  • Resistance values of the heater:
PART NUMBER
RESISTANCE VALUE IN OHM
4-60000H800-00
57+-3
4-60000H840-00
57+-3
4-60000H880-00
118+-5
4-60000H882-00
118+-5
4-60000H883-00
118+-5

     (c) If the fault continues:
       1 Replace DRAINMAST "F" [4DU] or only the cover or the heater tube assembly AMM 30-71-51-000-001 and AMM 30-71-51-400-001.
     (d) If the fault continues:
       1 Do a check and repair the wiring between:
  • CONTROL UNIT 5DU connector A/8 and DRAINMAST 4DU connector A/B
  • DRAINMAST 4DU connector A/C and GND
  • DRAINMAST 4DU connector A/A and GND ASM 307101.
   (2) If the green HTR LED of CONTROL UNIT 5DU comes on:
     (a) Do a check and repair the wiring if necessary between:
  • CONTROL UNIT 5DU connector A/11 and DEU-B 300RH1 connector C/34
  • CONTROL UNIT 5DU connector A/14 and CB 1DU
  • CONTROL UNIT 5DU connector A/15 and GND ASM 307101.
     (b) If the fault continues:
       1 Replace DEU-B [300RH1] AMM 23-73-47-000-001 and AMM 23-73-47-400-001.
     (c) If the fault continues:
       1 Do the trouble shooting procedure for the fault in DEU-B 300RH1 with connected Systems/Devices (Ref. TSM TASK 23-73-00-810-827).
Subtask 30-71-00-810-050-B ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message DRAINMAST HEATER FWD
   (1) If the green HTR LED of CONTROL UNIT 5DU does not come on:
     (a) Replace CONTROL UNIT, WASTE WATER ICE PROTECTION- [5DU] AMM 30-71-34-000-001 and AMM 30-71-34-400-001.
     (b) If the fault continues:
       1 Do a check of the resistance value of the drainmast heater and the temperature sensor. Refer to the resistance values in the tables.
  • Resistance values of the temperature sensor:
    ---------------------------------------------------------
    ! TEMPERATURE ! RESISTANCE VALUE IN OHM !
    ---------------------------------------------------------
    ! -10deg C (14deg F) ! 1784+-9 !
    !--------------------------!----------------------------!
    ! 0deg C (32deg F) ! 1854+-8 !
    !--------------------------!----------------------------!
    ! +10deg C (50deg F) ! 1926+-6 !
    !--------------------------!----------------------------!
    ! +20deg C (68deg F) ! 2000+-5 !
    !--------------------------!----------------------------!
    ! +30deg C (86deg F) ! 2076+-5 !
    !--------------------------!----------------------------!
    ! +40deg C (104deg F) ! 2153+-6 !
    ---------------------------------------------------------


  • Resistance values of the heater:
    --------------------------------------------------
    ! PART NUMBER ! RESISTANCE VALUE IN OHM !
    --------------------------------------------------
    ! 4-60000H800-00 ! 57+-3 !
    !-------------------!----------------------------!
    ! 4-60000H840-00 ! 57+-3 !
    !-------------------!----------------------------!
    ! 4-60000H880-00 ! 118+-5 !
    !-------------------!----------------------------!
    ! 4-60000H882-00 ! 118+-5 !
    !-------------------!----------------------------!
    ! 4-60000H883-00 ! 118+-5 !
    --------------------------------------------------


     (c) If the fault continues:
       1 Replace DRAINMAST "F" [4DU] or only the cover or the heater tube assembly AMM 30-71-51-000-001 and AMM 30-71-51-400-001.
     (d) If the fault continues:
       1 Do a check and repair the wiring between:
  • CONTROL UNIT 5DU connector A/8 and DRAINMAST 4DU connector A/B
  • DRAINMAST 4DU connector A/C and GND
  • DRAINMAST 4DU connector A/A and GND ASM 307101.
   (2) If the green HTR LED of CONTROL UNIT 5DU comes on:
     (a) Do a check and repair the wiring if necessary between:
  • CONTROL UNIT 5DU connector A/11 and DEU-B 300RH1 connector C/43
  • CONTROL UNIT 5DU connector A/14 and CB 1DU
  • CONTROL UNIT 5DU connector A/15 and GND ASM 307101.
     (b) If the fault continues:
       1 Replace DEU-B [300RH1] AMM 23-73-47-000-001 and AMM 23-73-47-400-001.
     (c) If the fault continues:
       1 Do the trouble shooting procedure for the fault in DEU-B 300RH1 with connected Systems/Devices (Ref. TSM TASK 23-73-00-810-827).
Subtask 30-71-00-710-051-A
B. Do the test as given in Para. 3.A.
5. Close-up
Subtask 30-71-00-860-050-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:29:45 UTC