Intermittent Operation of the Yellow Electric Pump
TASK 29-24-00-810-805-A
Intermittent Operation of the Yellow Electric Pump
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-24-00-710-058-A 4. Fault Isolation
Subtask 29-24-00-810-054-A
Subtask 29-24-00-710-059-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:30 UTC
Intermittent Operation of the Yellow Electric Pump
1. Possible Causes
- CURRENT TRANSFORMER [3807GX]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 29-24-00-810-801-A | Loss or Fluctuation of the Pressure of the Yellow Electric Pump |
| AMM 29-24-00-710-001 | Operational Test of the Yellow Auxiliary Power |
| AMM 29-24-15-000-001 | Removal of the Yellow Electric Pump Current Transformer |
| AMM 29-24-15-400-001 | Installation of the Yellow Electric Pump Current Transformer |
Subtask 29-24-00-710-058-A 4. Fault Isolation
Subtask 29-24-00-810-054-A
A. If the Yellow electric pump starts to operate and stops after some seconds during the operational test:
5. Close-up- Do a check of the red indicator light on the phase unbalance detector (3808GX).
- Replace the CURRENT TRANSFORMER [3807GX] AMM 29-24-15-000-001 and AMM 29-24-15-400-001.
- Do the troubleshooting procedure (Ref. TSM TASK 29-24-00-810-801).
Subtask 29-24-00-710-059-A
A. Do the test as given in Para. 3. A. to make sure that the operation is correct.