W DOC AIRBUS | TSM A320F

Yellow Electric Pump Motor Running with no Hydraulic Pressure


TASK 29-24-00-810-804-A
Yellow Electric Pump Motor Running with no Hydraulic Pressure


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 29-24-00-810-801-A
Loss or Fluctuation of the Pressure of the Yellow Electric Pump
AMM 29-13-14-000-001
Removal of the HP Manifold of the Yellow Hydraulic System
AMM 29-13-14-400-001
Installation of the HP Manifold of the Yellow Hydraulic System
AMM 29-13-45-610-001
Servicing of the HP-Filter
CMM 292028
CMM 292120
CMM 292121
AMM 29-24-00-710-001
Operational Test of the Yellow Auxiliary Power
AMM 29-24-21-000-001
Removal of the Yellow E-Pump Check Valve
AMM 29-24-21-400-001
Installation of the Yellow E-Pump Check Valve
AMM 29-24-51-000-001
Removal of the Electric Pump
AMM 29-24-51-400-001
Installation of the Electric Pump
3. Fault Confirmation
Subtask 29-24-00-710-056-A
A. Do the operational test of the Yellow electric pump AMM 29-24-00-710-001.
4. Fault Isolation
Subtask 29-24-00-810-053-A
A. If the test gives:
   (1) Fluctuation of the hydraulic pressure:
   (2) The PACKAGE E-PUMP [3075GX] operates but supplies no hydraulic pressure:
     (a) Remove the PACKAGE E-PUMP [3075GX] AMM 29-24-51-000-001.
     (b) Examine the:
     (c) If you find damage:
       1 Remove the CHECK VALVE Y [3083GM] AMM 29-24-21-000-001.
       2 Do a visual inspection of the CHECK VALVE Y [3083GM] for damage and missing parts.
       3 If parts are missing, do the subsequent before you install the new check valve:
       4 Install the CHECK VALVE Y [3083GM] AMM 29-24-21-400-001.
       5 Replace the PACKAGE E-PUMP [3075GX] AMM 29-24-51-400-001.
5. Close-up
Subtask 29-24-00-710-057-A
A. Do the test as given in Para. 3. A. to make sure that the operation is correct.
[Rev.8 from Aug 2018] 2026.04.04 04:29:30 UTC