Fault of the Ram Air Turbine
TASK 29-22-00-810-801-A
Fault of the Ram Air Turbine
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-22-00-865-050-A
Subtask 29-22-00-810-050-B
Subtask 29-22-00-860-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:28 UTC
Fault of the Ram Air Turbine
1. Possible Causes
- EJECTION ACTUATOR [1GE]
P/BSW 2805GE - P/BSW-EMER ELEC PWR/MAN ON [24XE]
- CHECK VALVE B [2050GM]
- RAT stowed switch
- RAT CTL PNL [3GE]
- wiring
- PRESSURE SWITCH
- SDAC-1 [1WV1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-24-00-810-806-A | Result of the EMER GEN Test Incorrect (Failure of the Switching) |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 29-10-00-863-003 | Pressurize the Blue Hydraulic System with a Hydraulic Ground Power-Cart |
| AMM 29-12-36-000-001 | Removal of the Check Valve of the Blue Electric Pump |
| AMM 29-12-36-400-001 | Installation of the Check Valve of the Blue Electric Pump |
| AMM 29-22-00-869-006 | Retraction of the Ram Air Turbine (RAT) on the Ground |
| ASM 292201 | |
| AMM 29-22-12-000-003 | Removal of the RAT Ground Control Unit |
| AMM 29-22-12-400-003 | Installation of the RAT Ground Control Unit |
| AMM 29-22-53-000-010 | Removal of the RAT Actuator |
| AMM 29-22-53-000-013 | Removal of the Pressure Switch |
| AMM 29-22-53-000-014 | Removal of the RAT Stowed Switch |
| AMM 29-22-53-400-010 | Installation of the RAT Actuator |
| AMM 29-22-53-400-013 | Installation of the Pressure Switch |
| AMM 29-22-53-400-014 | Installation of the RAT Stowed Switch |
| ASM 315402 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
| AMM 31-60-00-860-001 | EIS Start Procedure |
Subtask 29-22-00-865-050-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 29-22-00-860-053-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYD/RAT/CTL | 2801GE | D14 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYD/RAT/CTL | 2801GE | B13 |
| ** ON A/C ALL | |||
| 106VU | CSM/G /EV/MAN/SPLY | 6XE | B04 |
| 121VU | HYDRAULIC/RAT/SPLY/EXTN/SOL1 | 2803GE | P33 |
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(3) Look for fault indications on the upper ECAM DU and examine the RAT.
4. Fault Isolation(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(3) Look for fault indications on the upper ECAM DU and examine the RAT.
NOTE: The message RAT OUT (RAT not extended) shows in GREEN on the Memo page only in flight, this causes the message HYD RAT FAULT on the upper ECAM DU on ground. The message RAT OUT changes color to AMBER on ground.
Subtask 29-22-00-810-050-B
A. If the upper ECAM DU shows the message HYD RAT FAULT and the RAT is extended:
(a) Do a check for 28 VDC between:
1 Do a check and repair the wiring between:
(a) Replace the EJECTION ACTUATOR [1GE] AMM 29-22-53-000-010 and AMM 29-22-53-400-010.
(b) If the fault continues:
Subtask 29-22-00-810-051-B - Do a check for 28 VDC between the EJECTION ACTUATOR [1GE] connectors A/A and A/B, B/A and B/B ASM 292201.
NOTE: The solenoid valves are made unserviceable, if 28 VDC is supplied for more than 2 minutes.
WARNING:
MAKE SURE THAT THE RAT TRAVEL RANGE IS CLEAR BEFORE YOU EXTEND/RETRACT THE RAT.
(1) If there is no 28 VDC: - Retract the RAT AMM 29-22-00-869-006 and extend it again with the EMER ELEC POWER/MAN ON/AUTO P/BSW (24XE) on panel 21VU.
- Retract the RAT AMM 29-22-00-869-006 and extend it again with the RAT MAN ON P/BSW (2805GE) on panel 40VU.
NOTE: The uncommanded extension was due to a mechanical fault of the ejection jack or a spurious supply to one of the two deploy solenoids.
(2) If there is 28 VDC at one or both solenoids: (a) Do a check for 28 VDC between:
- The
P/BSW 2805GE pin 4 and ground - The P/BSW-EMER ELEC PWR/MAN ON [24XE] pin 7 and ground ASM 292201.
- Replace the related P/BSW.
1 Do a check and repair the wiring between:
- The
P/BSW 2805GE pin 4 and the EJECTION ACTUATOR [1GE] connector B/B - The P/BSW-EMER ELEC PWR/MAN ON [24XE] pin 7 and the EJECTION ACTUATOR [1GE] connector A/B ASM 292201.
- Do the trouble shooting procedure of the automatic deployment logic (Ref. TSM TASK 24-24-00-810-806).
(a) Replace the EJECTION ACTUATOR [1GE] AMM 29-22-53-000-010 and AMM 29-22-53-400-010.
(b) If the fault continues:
- Replace the CHECK VALVE B [2050GM] AMM 29-12-36-000-001 and AMM 29-12-36-400-001.
B. If the upper ECAM DU shows the message HYD RAT FAULT and the RAT is not extended:
1 Disconnect the electrical connector (1GE-D) from the EJECTION ACTUATOR [1GE] .
2 Do a check for 28 VDC at the electrical connector (1GE-D) between connector D/A and connector D/C ASM 292201.
3 If there is no 28 VDC:
a Disconnect the electrical connector (3GE-A) from the RAT CTL PNL [3GE] .
b Do again a check for 28 VDC at the electrical connector (1GE-D) between connector D/A and connector D/C ASM 292201.
c If there is no 28 VDC:
(a) Do a test of the lights of the RAT CTL PNL [3GE] with the TEST switch to make sure that the lights are serviceable.
(b) Examine the red pressure light on the RAT CTL PNL [3GE] .
(c) If the red pressure light is ON:
1 Disconnect the electrical connector (1GE-E) from the EJECTION ACTUATOR [1GE] .
2 If the fault does not continue:
a Replace the Pressure Switch AMM 29-22-53-000-013 and AMM 29-22-53-400-013.
b Connect the electrical connector (1GE-E) to the EJECTION ACTUATOR [1GE] .
3 If the fault continues:
a Do a check of the wiring between the electrical connector (1GE-E) and the RAT CTL PNL [3GE] ASM 292201.
b Do a check of the wiring between the electrical connector (1GE-E) and the SDAC-1 [1WV1] ASM 315402 and ASM 292201.
c Repair the wiring , as necessary.
d If disconnected, connect the electrical connector (1GE-E) to the EJECTION ACTUATOR [1GE] .
4 If the fault continues:
a Replace the RAT CTL PNL [3GE] .
5 If the fault continues:
a Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(d) If the red pressure light is OFF:
1 Do a check for 28 VDC between the RAT CTL PNL [3GE] connector A/L and A/J.
2 If there are 28 VDC:
a Do a check of the wiring between the electrical connector (1GE-E) and the SDAC-1 [1WV1] ASM 292201 and ASM 315402.
b If the fault continues:
a Replace the RAT CTL PNL [3GE] AMM 29-22-12-000-003 and AMM 29-22-12-400-003.
Subtask 29-22-00-860-054-A - Do a check of the RAT triangle indication shown on the lower ECAM DU.
- Disconnect the electrical connector (1GE-C) from the EJECTION ACTUATOR [1GE] .
- Electrically connect the pins B and C of the connector (1GE-C) ASM 292201.
- Replace the RAT stowed switch AMM 29-22-53-000-014 and AMM 29-22-53-400-014.
- Replace the RAT CTL PNL [3GE] AMM 29-22-12-000-003 and AMM 29-22-12-400-003.
- Do a check of the wiring for a GND connection between the EJECTION ACTUATOR [1GE] connector C/B and the SDAC connector AA/03D ASM 292201 and ASM 315402.
- Pressurize the Blue Hydraulic system with the Blue Electric pump AMM 29-10-00-863-003 and look on the lower ECAM DU.
1 Disconnect the electrical connector (1GE-D) from the EJECTION ACTUATOR [1GE] .
2 Do a check for 28 VDC at the electrical connector (1GE-D) between connector D/A and connector D/C ASM 292201.
3 If there is no 28 VDC:
- Disconnect the electrical connector (1GE-E) from the EJECTION ACTUATOR [1GE] .
- Replace the PRESSURE SWITCH AMM 29-22-53-000-013 and AMM 29-22-53-400-013.
- Replace the EJECTION ACTUATOR [1GE] AMM 29-22-53-000-010 and AMM 29-22-53-400-010.
- Do a check of the wiring for a GND connection between the EJECTION ACTUATOR [1GE] connector E/C and the SDAC connector AA/04G ASM 292201 and ASM 315402.
a Disconnect the electrical connector (3GE-A) from the RAT CTL PNL [3GE] .
b Do again a check for 28 VDC at the electrical connector (1GE-D) between connector D/A and connector D/C ASM 292201.
c If there is no 28 VDC:
- Replace the RAT CTL PNL [3GE] AMM 29-22-12-000-003 and AMM 29-22-12-400-003.
- Do a check and repair the wiring between the EJECTION ACTUATOR [1GE] connector D/A and the RAT CTL PNL [3GE] connector A/G ASM 292201.
(a) Do a test of the lights of the RAT CTL PNL [3GE] with the TEST switch to make sure that the lights are serviceable.
(b) Examine the red pressure light on the RAT CTL PNL [3GE] .
(c) If the red pressure light is ON:
1 Disconnect the electrical connector (1GE-E) from the EJECTION ACTUATOR [1GE] .
2 If the fault does not continue:
a Replace the Pressure Switch AMM 29-22-53-000-013 and AMM 29-22-53-400-013.
b Connect the electrical connector (1GE-E) to the EJECTION ACTUATOR [1GE] .
3 If the fault continues:
a Do a check of the wiring between the electrical connector (1GE-E) and the RAT CTL PNL [3GE] ASM 292201.
b Do a check of the wiring between the electrical connector (1GE-E) and the SDAC-1 [1WV1] ASM 315402 and ASM 292201.
c Repair the wiring , as necessary.
d If disconnected, connect the electrical connector (1GE-E) to the EJECTION ACTUATOR [1GE] .
4 If the fault continues:
a Replace the RAT CTL PNL [3GE] .
5 If the fault continues:
a Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(d) If the red pressure light is OFF:
1 Do a check for 28 VDC between the RAT CTL PNL [3GE] connector A/L and A/J.
2 If there are 28 VDC:
a Do a check of the wiring between the electrical connector (1GE-E) and the SDAC-1 [1WV1] ASM 292201 and ASM 315402.
b If the fault continues:
- Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
a Replace the RAT CTL PNL [3GE] AMM 29-22-12-000-003 and AMM 29-22-12-400-003.
C. Do the test as given in Para. 3. B. to make sure that operation is correct (no message shown).
5. Close-upSubtask 29-22-00-860-050-A