W DOC AIRBUS | TSM A320F

Fault of the Ram Air Turbine


TASK 29-22-00-810-801-A
Fault of the Ram Air Turbine


1. Possible Causes
  • EJECTION ACTUATOR [1GE]
  • P/BSW 2805GE
  • P/BSW-EMER ELEC PWR/MAN ON [24XE]
  • CHECK VALVE B [2050GM]
  • RAT stowed switch
  • RAT CTL PNL [3GE]
  • wiring
  • PRESSURE SWITCH
  • SDAC-1 [1WV1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-24-00-810-806-A
Result of the EMER GEN Test Incorrect (Failure of the Switching)
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
AMM 29-10-00-863-003
Pressurize the Blue Hydraulic System with a Hydraulic Ground Power-Cart
AMM 29-12-36-000-001
Removal of the Check Valve of the Blue Electric Pump
AMM 29-12-36-400-001
Installation of the Check Valve of the Blue Electric Pump
AMM 29-22-00-869-006
Retraction of the Ram Air Turbine (RAT) on the Ground
ASM 292201
AMM 29-22-12-000-003
Removal of the RAT Ground Control Unit
AMM 29-22-12-400-003
Installation of the RAT Ground Control Unit
AMM 29-22-53-000-010
Removal of the RAT Actuator
AMM 29-22-53-000-013
Removal of the Pressure Switch
AMM 29-22-53-000-014
Removal of the RAT Stowed Switch
AMM 29-22-53-400-010
Installation of the RAT Actuator
AMM 29-22-53-400-013
Installation of the Pressure Switch
AMM 29-22-53-400-014
Installation of the RAT Stowed Switch
ASM 315402
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
AMM 31-60-00-860-001
EIS Start Procedure
3. Fault Confirmation
Subtask 29-22-00-865-050-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUHYD/RAT/CTL2801GED14
** ON A/C NOT FOR ALL
49VUHYD/RAT/CTL2801GEB13
** ON A/C ALL
106VUCSM/G /EV/MAN/SPLY6XEB04
121VUHYDRAULIC/RAT/SPLY/EXTN/SOL12803GEP33
Subtask 29-22-00-860-053-A
B. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
   (2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
   (3) Look for fault indications on the upper ECAM DU and examine the RAT.
NOTE: The message RAT OUT (RAT not extended) shows in GREEN on the Memo page only in flight, this causes the message HYD RAT FAULT on the upper ECAM DU on ground. The message RAT OUT changes color to AMBER on ground.
4. Fault Isolation
Subtask 29-22-00-810-050-B
A. If the upper ECAM DU shows the message HYD RAT FAULT and the RAT is extended:
  • Do a check for 28 VDC between the EJECTION ACTUATOR [1GE] connectors A/A and A/B, B/A and B/B ASM 292201.
NOTE: The solenoid valves are made unserviceable, if 28 VDC is supplied for more than 2 minutes.
WARNING: MAKE SURE THAT THE RAT TRAVEL RANGE IS CLEAR BEFORE YOU EXTEND/RETRACT THE RAT.
   (1) If there is no 28 VDC:
  • Retract the RAT AMM 29-22-00-869-006 and extend it again with the EMER ELEC POWER/MAN ON/AUTO P/BSW (24XE) on panel 21VU.
  • Retract the RAT AMM 29-22-00-869-006 and extend it again with the RAT MAN ON P/BSW (2805GE) on panel 40VU.
     (a) If the operation of the RAT is satisfactory, no further actions are necessary.
NOTE: The uncommanded extension was due to a mechanical fault of the ejection jack or a spurious supply to one of the two deploy solenoids.
   (2) If there is 28 VDC at one or both solenoids:
     (a) Do a check for 28 VDC between:
  • The P/BSW 2805GE pin 4 and ground
  • The P/BSW-EMER ELEC PWR/MAN ON [24XE] pin 7 and ground ASM 292201.
     (b) If there is 28 VDC:
  • Replace the related P/BSW.
     (c) If there is no 28 VDC:
       1 Do a check and repair the wiring between:
  • The P/BSW 2805GE pin 4 and the EJECTION ACTUATOR [1GE] connector B/B
  • The P/BSW-EMER ELEC PWR/MAN ON [24XE] pin 7 and the EJECTION ACTUATOR [1GE] connector A/B ASM 292201.
   (3) If the fault continues:
   (4) If the fault continues:
     (a) Replace the EJECTION ACTUATOR [1GE] AMM 29-22-53-000-010 and AMM 29-22-53-400-010.
     (b) If the fault continues:
Subtask 29-22-00-810-051-B
B. If the upper ECAM DU shows the message HYD RAT FAULT and the RAT is not extended:
  • Do a check of the RAT triangle indication shown on the lower ECAM DU.
   (1) If the RAT triangle is shown in green:
  • Disconnect the electrical connector (1GE-C) from the EJECTION ACTUATOR [1GE] .
  • Electrically connect the pins B and C of the connector (1GE-C) ASM 292201.
     (a) If the fault does not continue:
     (b) If the fault continues:
     (c) If the fault continues:
  • Do a check of the wiring for a GND connection between the EJECTION ACTUATOR [1GE] connector C/B and the SDAC connector AA/03D ASM 292201 and ASM 315402.
   (2) If the RAT triangle is shown in white:
  • Pressurize the Blue Hydraulic system with the Blue Electric pump AMM 29-10-00-863-003 and look on the lower ECAM DU.
     (a) If the RAT triangle is shown in amber:
       1 Disconnect the electrical connector (1GE-D) from the EJECTION ACTUATOR [1GE] .
       2 Do a check for 28 VDC at the electrical connector (1GE-D) between connector D/A and connector D/C ASM 292201.
       3 If there is no 28 VDC:
  • Disconnect the electrical connector (1GE-E) from the EJECTION ACTUATOR [1GE] .
         a If the fault does not continue:
         b If the fault does continue:
         c If the fault continues:
  • Do a check of the wiring for a GND connection between the EJECTION ACTUATOR [1GE] connector E/C and the SDAC connector AA/04G ASM 292201 and ASM 315402.
       4 If there is 28 VDC:
         a Disconnect the electrical connector (3GE-A) from the RAT CTL PNL [3GE] .
         b Do again a check for 28 VDC at the electrical connector (1GE-D) between connector D/A and connector D/C ASM 292201.
         c If there is no 28 VDC:
         d If there is 28 VDC:
  • Do a check and repair the wiring between the EJECTION ACTUATOR [1GE] connector D/A and the RAT CTL PNL [3GE] connector A/G ASM 292201.
   (3) If the RAT triangle is shown in amber:
     (a) Do a test of the lights of the RAT CTL PNL [3GE] with the TEST switch to make sure that the lights are serviceable.
     (b) Examine the red pressure light on the RAT CTL PNL [3GE] .
     (c) If the red pressure light is ON:
       1 Disconnect the electrical connector (1GE-E) from the EJECTION ACTUATOR [1GE] .
       2 If the fault does not continue:
         a Replace the Pressure Switch AMM 29-22-53-000-013 and AMM 29-22-53-400-013.
         b Connect the electrical connector (1GE-E) to the EJECTION ACTUATOR [1GE] .
       3 If the fault continues:
         a Do a check of the wiring between the electrical connector (1GE-E) and the RAT CTL PNL [3GE] ASM 292201.
         b Do a check of the wiring between the electrical connector (1GE-E) and the SDAC-1 [1WV1] ASM 315402 and ASM 292201.
         c Repair the wiring , as necessary.
         d If disconnected, connect the electrical connector (1GE-E) to the EJECTION ACTUATOR [1GE] .
       4 If the fault continues:
         a Replace the RAT CTL PNL [3GE] .
       5 If the fault continues:
         a Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
     (d) If the red pressure light is OFF:
       1 Do a check for 28 VDC between the RAT CTL PNL [3GE] connector A/L and A/J.
       2 If there are 28 VDC:
         a Do a check of the wiring between the electrical connector (1GE-E) and the SDAC-1 [1WV1] ASM 292201 and ASM 315402.
         b If the fault continues:
       3 If there are no 28 VDC:
         a Replace the RAT CTL PNL [3GE] AMM 29-22-12-000-003 and AMM 29-22-12-400-003.
Subtask 29-22-00-860-054-A
C. Do the test as given in Para. 3. B. to make sure that operation is correct (no message shown).
5. Close-up
Subtask 29-22-00-860-050-A
A. De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.