Indication of the Hydraulic Fluid Quantity of the Blue Reservoir shows High Level


TASK 29-12-00-810-817-A
Indication of the Hydraulic Fluid Quantity of the Blue Reservoir shows High Level


1. Possible Causes
  • gas leaks
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 29-12-00-810-801-A
Loss of the Blue Reservoir Pressurization
TSM TASK 29-12-00-810-803-A
Loss of the Correct Quantity in the Blue Hydraulic Reservoir
TSM TASK 29-12-00-810-818-A
Indication of the Hydraulic Fluid Quantity of the Blue Reservoir shows High or Low Level or fluctuates
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
AMM 29-00-00-870-008
Bleeding Procedure of the Blue Hydraulic System Upstream of the Blue E-Pump
AMM 29-00-00-870-009
Bleeding Procedure of the Blue Hydraulic System Downstream of the Blue E-Pump
AMM 29-10-00-200-002
Check Reservoir Air Pressure on Reservoir Gauge
AMM 29-10-00-200-005
Check Nitrogen Charge Pressure on the Blue Main System Accumulator
AMM 29-10-00-200-008
Check Nitrogen Charge Pressure on Hydraulic Power Accumulators
AMM 29-10-00-680-003
Drainage of the Reservoir of the Blue Hydraulic System
AMM 29-14-00-614-002
Pressurization of the Hydraulic Reservoirs through the Ground Connector
AMM 31-60-00-860-001
EIS Start Procedure
AMM 31-60-00-860-002
EIS Stop Procedure
3. Fault Confirmation
Subtask 29-12-00-865-063-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
121VUHYDRAULIC/HYD/QTY/IND1831GQP35
Subtask 29-12-00-860-071-A
B. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
   (2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
   (3) On the ECAM control panel on the center pedestal, push the HYD pushbutton switch. Make sure that the HYD page is shown on the system display of the ECAM.
   (4) Look for fault indications on the upper ECAM DU, the lower ECAM DU and panel 40VU.
4. Fault Isolation
Subtask 29-12-00-810-074-A
A. If the Fault Confirmation gives:

  • The content indication shows high fluid level on the lower ECAM DU:

    - Do a visual check of the fluid quantity shown on the reservoir quantity indicator (1834GQ) on the ground service panel of the Green hydraulic system.
    - Do a visual check of the fluid quantity shown on the fluid content indicator of the Blue reservoir.
    - Do a check of the pressure of the Blue system accumulator AMM 29-10-00-200-005 or AMM 29-10-00-200-008.
    - Do a check of the pressure of the Blue hydraulic reservoir AMM 29-10-00-200-002.
   (1) If the three hydraulic fluid quantity indicators show different quantities and the pressures of the accumulator and the reservoir are correct:
NOTE: The maximum permitted difference between the quantity indicators is 0.8 liter.
     (a) Do the troubleshooting of the quantity indication system (Ref. TSM TASK 29-12-00-810-803).
   (2) If the three hydraulic fluid quantity indicators show high level and the pressures of the accumulator and the reservoir are correct:
     (a) Drain the hydraulic fluid until you have the correct fluid quantity in the reservoir AMM 29-10-00-680-003.
     (b) Pressurize the reservoir of the Blue hydraulic system AMM 29-14-00-614-002.
   (3) If the three hydraulic fluid quantity indicators show high level, the pressure of the accumulator is correct, but the reservoir pressure is less than the permitted tolerance:
     (a) Do a check for external gas leaks on the reservoir and repair the defective components as necessary AMM 29-10-00-200-002.
     (b) If you find no external gas leaks, or the fault continues:
       1 Do the troubleshooting for the loss of the reservoir pressurization (Ref. TSM TASK 29-12-00-810-801).
       2 Drain the hydraulic fluid until you have the correct fluid quantity in the reservoir AMM 29-10-00-680-003.
       3 Pressurize the reservoir of the Blue hydraulic system AMM 29-14-00-614-002.
       4 After 5 minutes, read the gage of the fluid quantity indicator of the Blue reservoir.
         a If the difference of the fluid quantity is not more than 1 liter:
  • No further actions are necessary.
         b If the difference of the fluid quantity is more than 1 liter:
     (c) If the fault continues:
       1 Do the troubleshooting procedure (Ref. TSM TASK 29-12-00-810-818).
   (4) If the three hydraulic fluid quantity indicators show high level, the pressure of the reservoir is correct, but the accumulator pressure is less than the permitted tolerance:
     (a) Do the troubleshooting procedure (Ref. TSM TASK 29-12-00-810-818).
Subtask 29-12-00-860-072-A
B. Do the procedure as given in Para. 3. B. to make sure that the operation of the hydraulic quantity indication is correct.
5. Close-up
Subtask 29-12-00-860-073-A
A. Put the aircraft back to the serviceable condition.
   (1) Do the EIS stop procedure
AMM 31-60-00-860-002.
   (2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.