APU Fuel Supply Failure
TASK 28-29-00-810-801-A
APU Fuel Supply Failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 28-29-00-710-050-A
Subtask 28-29-00-810-050-B
Subtask 28-29-00-860-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:53 UTC
APU Fuel Supply Failure
1. Possible Causes
- ACTUATOR-APU FUEL LP VALVE [3QF]
- APU FUEL LP VALVE 14QM
- RELAY 4KD
- RELAY 5WF
- RELAY 6WF
- RELAY 6QC
- Capacitor 74KD
- Capacitor 76KD
- Resistor 75KD
- wiring
- FUEL LINE VENT pushbutton switch
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 28-29-00-810-802-A | APU Fuel LP Valve operates with one Motor only |
| ASM 262201 | |
| ASM 282201 | |
| AMM 28-29-00-710-001 | Operational Test of the APU Low Pressure Fuel Valve using each individual Motor in turn |
| AMM 28-29-41-000-001 | Removal of the APU Fuel Low-Pressure Valve |
| AMM 28-29-41-400-001 | Installation of the APU Fuel Low-Pressure Valve |
| AMM 28-29-51-000-001 | Removal of the APU Fuel LP Valve Actuator |
| AMM 28-29-51-400-001 | Installation of the APU Fuel LP Valve Actuator |
| ASM 496100 | |
| ASM 496101 |
Subtask 28-29-00-710-050-A
A. Do the operational test of the APU LP fuel-valve using each individual motor in turn AMM 28-29-00-710-001.
4. Fault IsolationSubtask 28-29-00-810-050-B
A. If the test with both motors is not correct:
Subtask 28-29-00-810-051-A Subtask 28-29-00-710-051-A - replace the ACTUATOR-APU FUEL LP VALVE [3QF] AMM 28-29-51-000-001 and AMM 28-29-51-400-001.
NOTE: When the actuator-APU fuel LP valve is removed, do a check of the APU fuel LP valve for correct function. If the function is not correct replace the APU FUEL LP VALVE 14QM AMM 28-29-41-000-001 and AMM 28-29-41-400-001.
(1) If the fault continues:- do a check of the RELAY 4KD and replace if necessary.
- do a check of the RELAY 5WF and replace if necessary.
- do a check of the RELAY 6WF and replace if necessary.
- do a check of the RELAY 6QC and replace if necessary.
NOTE: When the symptom were APU SHUT DOWN at the first start and the second start is OK.
(6) If the fault continues:- do a check of the Capacitor 74KD , Capacitor 76KD , Resistor 75KD and replace if necessary.
Use wiring ASM 496100 for FIN identification.
- do a check and repair the wiring from the:
CB 2KD to the APU MASTER SW 14KD via the RELAY 4KD,
CB 3WF to the RELAY 5WF,
RELAY 5WF to the GND,
CB 4WF to the RELAY 6WF,
RELAY 6WF to the GND,
CB 3QC to the FUEL LINE VENT pushbutton switch 8QC ASM 496101, ASM 262201 and ASM 282201.
- replace the FUEL LINE VENT pushbutton switch .
C. Do the test given in Para. 3.
5. Close-upSubtask 28-29-00-860-050-A
A. Put the aircraft back to its initial configuration.