Fuel Pumps - Center Tank Autofeed Failure (Pumps Do Not Stop At Wing-Tank(s) Innercell Full Level)


TASK 28-21-00-810-821-A
Fuel Pumps - Center Tank Autofeed Failure (Pumps Do Not Stop At Wing-Tank(s) Innercell Full Level)


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
WARNING: WHEN YOU DO WORK ON THE FUEL SYSTEM WIRING, YOU MUST USE TEST EQUIPMENT THAT IS APPROVED (REFER TO INTERNATIONAL OR NATIONAL SPECIFICATIONS FOR INTRINSICALLY SAFE TEST EQUIPMENT: EN50020, UL913 OR EQUIVALENT). TEST EQUIPMENT THAT IS NOT APPROVED CAN CAUSE FIRE OR AN EXPLOSION.
1. Possible Causes
  • RELAY-CTR TK AUTO CONTROL, PUMP 1(2) 41QA(42QA) 92VU
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 28-21-00-810-813-A
Fuel Pumps - Center Tank Fuel Pump No. 1 (Left Side) 37QA System Malfunction
TSM TASK 28-21-00-810-814-A
Fuel Pumps - Center Tank Fuel Pump No. 2 (Right Side) 38QA System Malfunction
TSM TASK 28-21-00-810-817-A
Fuel Pumps - Center Tank Fuel Pump No. 1 (Left Side) Contactor Control Failure (Manual Control)
TSM TASK 28-21-00-810-818-A
Fuel Pumps - Center Tank Fuel Pump No. 2 (Right Side) Contactor Control Failure (Manual Control)
AMM 28-21-00-720-001
Functional Test of the Center-Tank Fuel Control
3. Fault Confirmation
Subtask 28-21-00-710-070-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the Functional Test of the Center-Tank Fuel Control (in manual and auto control modes) AMM 28-21-00-720-001.
4. Fault Isolation
Subtask 28-21-00-810-070-F ** ON A/C NOT FOR ALL
A. Procedure
   (1) If the:
     (a) Center-Tank Fuel Pumps No 1 do not operate correctly in the Manual Mode do:
       1 Fuel Pumps - Center Tank Pump-Fuel No 1 System Failure (Ref. TSM TASK 28-21-00-810-813).
       2 Fuel Pumps - Center Tank Pump-Fuel No 1 Contactor Control Failure (Ref. TSM TASK 28-21-00-810-817).
     (b) Center-Tank Fuel Pumps No 2 do not operate correctly in the Manual Mode do:
       1 Fuel Pumps - Center Tank Pump-Fuel No 2 System Failure (Ref. TSM TASK 28-21-00-810-814).
       2 Fuel Pumps - Center Tank Pump-Fuel No 2 Contactor Control Failure (Ref. TSM TASK 28-21-00-810-818).
   (2) If a pump does not stop during the test given in Para. 3.A., Auto Mode:
  • examine the ECAM FUEL System Display page to see which side(s) has/have not shut off correctly.
NOTE: The CTR TANK PUMP INDICATIONS are:
  • In line - Green - Pump pressure normal (pump contactor on)
  • LO - Amber - Pump low pressure (pump contactor on)
  • Cross line - Green - Pump contactor off and auto shut off required
  • Cross line - Amber - Pump contactor off and auto shut off not required.
NOTE: For the ECAM warning/caution - AUTO FEED FAULT to have been given by the FWC, a CTR TK PUMP 1 or 2 AUTO SHUT OFF REQUIRED signal has been received.
This shows that:
  • the FLSCU-1(2) input of CTR TK PUMP RECIRCULATION CTL off (a ground) has operated correctly
  • the RELAY 51QA(52QA) has operated correctly (remained de-energized)
  • the RELAY 41QA(42QA), contacts C to 6 (the source of the AUTO SHUT OFF REQUIRED signal) have operated correctly (energized).
   (3) If the fault continues:
     (a) Do a check of the RELAY-CTR TK AUTO CONTROL, PUMP 1(2) 41QA(42QA) 92VU (contacts B to 3) and replace, if necessary.
     (b) Do the test given in Para. 3.A.