NOTE: This task is applicable only for the new-generation side-stick unit.
1. Possible CausesSSU-CAPT (100CE1) SSU-F/O (100CE2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-10-00-810-819-A | Failure of the Right Green Aileron Servo Control Position Transducer |
| TSM TASK 27-10-00-810-820-A | Loss of the Right Green Aileron Position Transducer Signal for the ELAC 1 |
| TSM TASK 27-10-00-810-821-A | Loss of the Servovalve Signal for the Right Green Aileron Servo Control |
| TSM TASK 27-10-00-810-823-A | Failure of the Right Green Aileron Servo Control Servovalve |
| TSM TASK 27-10-00-810-824-A | Failure of the Right Green Aileron Servo Control Solenoid Valve |
| TSM TASK 27-10-00-810-825-A | Loss of the Right Aileron Changeover Signal for the ELAC 1 |
| AMM 27-92-41-000-802 | Removal of the New-Generation Side-Stick Unit |
| AMM 27-92-41-400-802 | Installation of the New-Generation Side-Stick Unit |
| AMM 29-10-00-863-001 | Pressurize the Green Hydraulic System with a Hydraulic Ground Power-Cart |
Subtask 27-93-00-700-217-A
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 27-93-00-810-269-A
A. With Green hydraulic system pressurized AMM 29-10-00-863-001, on the F/CTL page of the Lower ECAM DU, if the R AIL G servocontrol indication is amber:
(2) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
(4) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
(6) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
(8) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
(10) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
Subtask 27-93-00-810-270-A - do this trouble shooting procedure (Ref. TSM TASK 27-10-00-810-819).
(2) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
- do this trouble shooting procedure (Ref. TSM TASK 27-10-00-810-820).
(4) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
- do this trouble shooting procedure (Ref. TSM TASK 27-10-00-810-821).
(6) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
- do this trouble shooting procedure (Ref. TSM TASK 27-10-00-810-823).
(8) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
- do this trouble shooting procedure (Ref. TSM TASK 27-10-00-810-824).
(10) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
- do this trouble shooting procedure (Ref. TSM TASK 27-10-00-810-825).
B. With Green hydraulic system pressurized AMM 29-10-00-863-001, on the F/CTL page of the lower ECAM DU, if the R AIL G servocontrol indication is not amber:
- replace the
SSU-CAPT (100CE1) andSSU-F/O (100CE2) , AMM 27-92-41-000-802 and AMM 27-92-41-400-802.