W DOC AIRBUS | TSM A320F

Loss of the Side Stick Priority Signal for One ELAC


TASK 27-93-00-810-919-A
Loss of the Side Stick Priority Signal for One ELAC


1. Possible Causes
  • ELAC-1 [2CE1]
  • wiring of the STICK PRIORITY CAPT (DSI35) and STICK PRIORITY F/O (DSI36) signals
  • ELAC-2 [2CE2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-92-00-810-830-A
Loss of the Side Stick Priority Signal
ASM 279217
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-710-003
Operational Test of the Side Stick Priority
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-93-00-700-156-A
A. Test
   (1) Do a check of the Post Flight Report (PFR):
     (a) If the F/CTL maintenance status is shown with the ECAM warning message F/CTL SIDE STICK PRIORITY, refer to the trouble shooting procedure "Loss of the Side Stick Priority Signal" (Ref. TSM TASK 27-92-00-810-830).
     (b) If the ECAM warning message F/CTL SIDE STICK PRIORITY only is shown:
1. Do the operational test of the side stick priority AMM 27-96-00-710-003.
2. Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
NOTE: If the ECAM warning message F/CTL ELAC 1 FAULT or F/CTL ELAC 2 FAULT is shown on the PFR after the ECAM warning message F/CTL SIDE STICK PRIORITY, ignore the ECAM warning message F/CTL ELAC 1 FAULT or F/CTL ELAC 2 FAULT. It was generated by the reset of ELAC 1 or ELAC 2 computer done during an operational procedure (FCOM) related to the ECAM warning message F/CTL SIDE STICK PRIORITY.
4. Fault Isolation
Subtask 27-93-00-810-167-A
A. If the tests give the maintenance message CHECK PRIORITY WIRING:
  • do the tests given in Para. 3. with only the ELAC1 engaged for the operational test of the side stick priority.
   (1) If the tests give the above maintenance message again:
     (a) If the fault continues:
  • do a check and repair the wiring of the STICK PRIORITY CAPT (DSI35) and STICK PRIORITY F/O (DSI36) signals from the ELAC1 (2CE1) COM part and MON part to the first terminal block ASM 279217.
   (2) If the tests do not give a maintenance message:
     (a) If the fault continues:
  • do a check and repair the wiring of the STICK PRIORITY CAPT (DSI35) and STICK PRIORITY F/O (DSI36) signals from the ELAC2 (2CE2) COM part and MON part to the first terminal block ASM 279217.
Subtask 27-93-00-700-157-A
B. Do the tests given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:06 UTC