W DOC AIRBUS | TSM A320F

Loss of the Signal of the Right Yellow Elevator-Servocontrol Position- Transducer by the ELAC 2


TASK 27-93-00-810-877-A
Loss of the Signal of the Right Yellow Elevator-Servocontrol Position- Transducer by the ELAC 2


1. Possible Causes
  • ELAC-2 [2CE2]
  • wiring of the POS XDCR COM (ANI 2-2) signal from the ELAC 2 (2CE2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-90-00-810-814-A
Loss of the ACS1 Signal of the ELAC2 COM Side
TSM TASK 27-90-00-810-815-A
Loss of the ACS1 Signal of the ELAC2 MON Side
TSM TASK 27-90-00-810-816-A
Loss of the ACS1 of the ELAC2 COM and MON Sides
ASM 279308
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-93-00-700-136-A
A. Test
   (1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
     (a) If the ground scanning gives the maintenance message:
ELAC2 OR WIRING FROM R Y ELEV POS XDCR 34CE2
  • refer to Para. Fault Isolation.
     (b) If the ground scanning gives at least two maintenance messages of the two lists below:
First list:
  • ELAC2 COM OR INPUT OF THS ACTR XDCR1 9CE
  • ELAC2 OR WIRING FROM L G ELEV POS XDCR 34CE1
  • ELAC2 OR WIRING FROM R Y ELEV POS XDCR 34CE2
    Second list:
  • ELAC2 MON OR INPUT OF THS ACTR XDCR1 9CE
  • ELAC2 OR WIRING FROM L ELEV POS MON XDCR
  • ELAC2 OR WIRING FROM R ELEV POS MON XDCR
  • ELAC2 OR WIRING FROM L B ELEV MODE XDCR 34CE3
  • ELAC2 OR WIRING FROM R Y ELEV MODE XDCR 34CE4
       1 First case:
Combination of maintenance messages of the first list, do this trouble shooting procedure (Ref. TSM TASK 27-90-00-810-814).
       2 Second case:
Combination of maintenance messages of the second list, do this trouble shooting procedure (Ref. TSM TASK 27-90-00-810-815).
       3 Third case:
Combination of maintenance messages of the first and second lists, do this trouble shooting procedure (Ref. TSM TASK 27-90-00-810-816).
4. Fault Isolation
Subtask 27-93-00-810-123-A
A. If the test gives the maintenance message:
ELAC2 OR WIRING FROM R Y ELEV POS XDCR 34CE2
   (1) If the fault continues:
  • Do a check and repair the wiring of the POS XDCR COM (ANI 2-2) signal from the ELAC 2 (2CE2) to the first terminal block ASM 279308.
Subtask 27-93-00-700-137-A
B. Do the tests given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:00 UTC