Loss of the ACS1 Signal of the ELAC2 MON Side
TASK 27-90-00-810-815-A
Loss of the ACS1 Signal of the ELAC2 MON Side
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-90-00-860-050-A
Subtask 27-90-00-810-064-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:52 UTC
Loss of the ACS1 Signal of the ELAC2 MON Side
1. Possible Causes
- ELAC-2 [2CE2]
- SEC-2 [1CE2]
- wiring of the ACS1 SPLY signal from the ELAC2 MON side to the COM side
- wiring of the ACS1 SPLY MON signal from the ELAC2 COM side to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-90-00-810-801-A | Failure of an Alternating Current Supply (ACS) |
| ASM 279308 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 29-23-00-863-001 | Pressurize the Green Hydraulic System from the Yellow Hydraulic System through the PTU with the Electric Pump |
| AMM 29-23-00-864-001 | Depressurize the Green and Yellow Hydraulic Systems after Operation of the PTU |
| AMM 29-24-00-863-001 | Pressurize the Yellow Hydraulic System with the Electric Pump |
| AMM 29-24-00-864-001 | Depressurize the Yellow Hydraulic System |
Subtask 27-90-00-860-050-A
A. Aircraft Maintenance Configuration
(1) Pressurize the Green and Yellow hydraulic systems AMM 29-23-00-863-001 and AMM 29-24-00-863-001.
(2) Depressurize the Green and Yellow hydraulic systems AMM 29-23-00-864-001 and AMM 29-24-00-864-001.
Subtask 27-90-00-740-077-A 4. Fault Isolation(1) Pressurize the Green and Yellow hydraulic systems AMM 29-23-00-863-001 and AMM 29-24-00-863-001.
(2) Depressurize the Green and Yellow hydraulic systems AMM 29-23-00-864-001 and AMM 29-24-00-864-001.
Subtask 27-90-00-810-064-A
A. If the ground scanning gives at least two maintenance messages of the list below:
ELAC2 MON OR INPUT OF THS ACTR XDCR1 9CE
ELAC2 OR WIRING FROM L ELEV POS MON XDCR
ELAC2 OR WIRING FROM R ELEV POS MON XDCR
ELAC2 OR WIRING FROM L B ELEV MODE XDCR 34CE3
ELAC2 OR WIRING FROM R Y ELEV MODE XDCR 34CE4
(1) Remove the ELAC2 AMM 27-93-34-000-001 and the SEC2 AMM 27-94-34-000-001.
(2) At the ELAC2 receptacle, do a check of the resistance between the pin AB/7K and the pin AB/8K ASM 279308:
(a) If the resistance is less than 10 Ohms:
1 Do this procedure (Ref. TSM TASK 27-90-00-810-801).
2 Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
3 Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(b) If the resistance value is more than 10 Ohms:
a Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
b Install the SEC2 AMM 27-94-34-400-001.
c If the fault continues:
Subtask 27-90-00-740-078-A ELAC2 MON OR INPUT OF THS ACTR XDCR1 9CE
ELAC2 OR WIRING FROM L ELEV POS MON XDCR
ELAC2 OR WIRING FROM R ELEV POS MON XDCR
ELAC2 OR WIRING FROM L B ELEV MODE XDCR 34CE3
ELAC2 OR WIRING FROM R Y ELEV MODE XDCR 34CE4
(1) Remove the ELAC2 AMM 27-93-34-000-001 and the SEC2 AMM 27-94-34-000-001.
(2) At the ELAC2 receptacle, do a check of the resistance between the pin AB/7K and the pin AB/8K ASM 279308:
(a) If the resistance is less than 10 Ohms:
1 Do this procedure (Ref. TSM TASK 27-90-00-810-801).
2 Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
3 Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(b) If the resistance value is more than 10 Ohms:
- do a check of the wiring of the ACS1 SPLY signal from the ELAC2 MON side to the COM side ASM 279308:
. pins AE/1J and AE/1K to pins AE/11B and AE/10B of the ELAC2 MON side
. pins AE/10A and AE/11A of the ELAC2 MON side to pins AB/8J and AB/7J of the ELAC2 COM side.
- repair it
- install the ELAC2 AMM 27-93-34-400-001 and the SEC2 AMM 27-94-34-400-001.
- replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
a Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
b Install the SEC2 AMM 27-94-34-400-001.
c If the fault continues:
- do a check and repair the wiring of the ACS1 SPLY MON signal from the ELAC2 COM side to the first terminal block , pins AB/7K and AB/8K ASM 279308.
- if the wiring is correct, do the failure of an alternating current supply (ACS) procedure (Ref. TSM TASK 27-90-00-810-801).
B. Do the test given in Para. 3.