W DOC AIRBUS | TSM A320F

Loss of the ACS1 Signal of the SEC2 MON Side


TASK 27-90-00-810-822-A
Loss of the ACS1 Signal of the SEC2 MON Side


1. Possible Causes
  • ELAC-2 [2CE2]
  • SEC-2 [1CE2]
  • wiring of the ACS1 SPLY XDCR signal from the SEC2 MON side to the COM side
  • wiring of the ACS1 SPLY MON signal from the SEC2 COM side to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-90-00-810-801-A
Failure of an Alternating Current Supply (ACS)
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
ASM 279408
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-90-00-740-091-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-90-00-810-071-A
A. If the ground scanning gives at least two maintenance messages of the list below:
SEC2 OR WIRING FROM L B ELEV MODE XDCR 34CE3
SEC2 OR WIRING FROM L ELEV POS MON XDCR
SEC2 OR WIRING FROM R B ELEV MODE XDCR 34CE4
SEC2 OR WIRING FROM R ELEV POS MON XDCR
SEC2 MON OR INPUT OF THS ACTR XDCR3 9CE
   (1) Remove the ELAC2 AMM 27-93-34-000-001 and the SEC2 AMM 27-94-34-000-001.
   (2) At the SEC2 receptacle, do a check of the resistance between the pin AB/9E and the pin AB/9F ASM 279408:
     (a) If the resistance is less than 10 Ohms:
       1 Do this procedure (Ref. TSM TASK 27-90-00-810-801).
       2 Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
       3 Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
     (b) If the resistance is more than 10 Ohms:
  • do a check of the wiring of the ACS1 SPLY XDCR signal from the SEC2 MON side to the COM side :
    . pins AE/10E and AE/10D to pins AB/8E and AB/8F ASM 279408.
       1 If the wiring is not correct:
         a If the fault continues:
       2 If the wiring is correct:
         a Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
         b Install the ELAC2 AMM 27-93-34-400-001.
         c If the fault continues:
  • do a check and repair the wiring of the ACS1 SPLY MON signal from the SEC2 COM side to the first terminal block , pins AB/9E and AB/9F ASM 279408.
  • if the wiring is correct, do the failure of an alternating current supply (ACS) procedure (Ref. TSM TASK 27-90-00-810-801).
Subtask 27-90-00-740-092-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:53 UTC