Loss of the ACS1 Signal of the SEC2 COM Side
TASK 27-90-00-810-821-A
Loss of the ACS1 Signal of the SEC2 COM Side
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-90-00-740-089-A 4. Fault Isolation
Subtask 27-90-00-810-070-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:53 UTC
Loss of the ACS1 Signal of the SEC2 COM Side
1. Possible Causes
- ELAC-2 [2CE2]
- SEC-2 [1CE2]
- wiring of the ACS1 SPLY XDCR signal from the SEC2 COM side to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-90-00-810-801-A | Failure of an Alternating Current Supply (ACS) |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| ASM 279408 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-90-00-740-089-A 4. Fault Isolation
Subtask 27-90-00-810-070-A
A. If the ground scanning gives at least two maintenance messages of the list below:
SEC2 OR WIRING FROM L G ELEV POS XDCR 34CE1
SEC2 OR WIRING FROM R Y ELEV POS XDCR 34CE2
SEC2 COM OR INPUT OF THS ACTR XDCR3 9CE
(1) Remove the ELAC2 AMM 27-93-34-000-001 and the SEC2 AMM 27-94-34-000-001.
(2) At the SEC2 receptacle, do a check of the resistance between the pin AA/12F and the pin AA/12G ASM 279408:
(a) If the resistance is less than 10 Ohms:
1 Do this procedure (Ref. TSM TASK 27-90-00-810-801).
2 Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
3 Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(b) If the resistance is more than 10 Ohms:
1 Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
2 Install the ELAC2 AMM 27-93-34-400-001.
3 If the fault continues:
Subtask 27-90-00-740-090-A SEC2 OR WIRING FROM L G ELEV POS XDCR 34CE1
SEC2 OR WIRING FROM R Y ELEV POS XDCR 34CE2
SEC2 COM OR INPUT OF THS ACTR XDCR3 9CE
(1) Remove the ELAC2 AMM 27-93-34-000-001 and the SEC2 AMM 27-94-34-000-001.
(2) At the SEC2 receptacle, do a check of the resistance between the pin AA/12F and the pin AA/12G ASM 279408:
(a) If the resistance is less than 10 Ohms:
1 Do this procedure (Ref. TSM TASK 27-90-00-810-801).
2 Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
3 Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(b) If the resistance is more than 10 Ohms:
1 Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
2 Install the ELAC2 AMM 27-93-34-400-001.
3 If the fault continues:
- do a check and repair the wiring of the ACS1 SPLY XDCR signal from the SEC2 COM side to the first terminal block , pins AA/12F and AA/12G ASM 279408.
- if the wiring is correct, do the failure of an alternating current supply (ACS) procedure (Ref. TSM TASK 27-90-00-810-801).
B. Do the test given in Para. 3.