Loss of the ACS1 Signal of the ELAC1 MON Side and SEC1 MON Side


TASK 27-90-00-810-820-A
Loss of the ACS1 Signal of the ELAC1 MON Side and SEC1 MON Side


1. Possible Causes
  • ELAC-1 [2CE1]
  • SEC-1 [1CE1]
  • wiring of the ACS1 SPLY XDCR signal from the SEC1 MON side to the COM side
  • wiring of the ACS1 SPLY XDCR COM signal from the SEC1 MON side to the second terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-90-00-810-801-A
Failure of an Alternating Current Supply (ACS)
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
ASM 279407
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-90-00-740-087-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-90-00-810-069-A
A. If the ground scanning gives at least two maintenance messages of the list below:
L ELEV POS MON XDCR OF ELAC1/SEC1
L G ELEV MODE XDCR 34CE1
R B ELEV POS MON XDCR OF ELAC1/SEC1
R Y ELEV MODE XDCR 34CE2
THS ACTR XDCR2 MON 9CE
   (1) Remove the ELAC1 AMM 27-93-34-000-001 and the SEC1 AMM 27-94-34-000-001.
   (2) At the SEC1 receptacle, do a check of the resistance between the pin AB/9E and the pin AB/9F ASM 279407:
     (a) If the resistance is less than 10 Ohms:
       1 Do this procedure (Ref. TSM TASK 27-90-00-810-801).
       2 Replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
       3 Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
     (b) If the resistance is more than 10 Ohms:
       1 Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
Install the ELAC1 AMM 27-93-34-400-001.
       2 If the fault continues:
       3 If the fault continues:
         a Do a check of the wiring of the ACS1 SPLY XDCR signal from the SEC1 MON side to the COM side , pins AE/10D and AE/10E to pins AB/8F and AB/8E ASM 279407.
  • if the wiring is correct, continue the trouble shooting
  • if the wiring is not correct, repair the above wiring.
         b Do a check of the wiring of the ACS1 SPLY XDCR COM signal from the SEC1 MON side to the second terminal block , pins AB/9E and AB/9F ASM 279407.
  • if the wiring is correct, continue the trouble shooting
  • if the wiring is not correct, repair the above wiring.
         c Do the failure of an alternating current supply (ACS) procedure (Ref. TSM TASK 27-90-00-810-801).
Subtask 27-90-00-740-088-A
B. Do the test given in Para. 3.