Loss of the ACS2 Signal of the ELAC2 COM Side


TASK 27-90-00-810-808-A
Loss of the ACS2 Signal of the ELAC2 COM Side


1. Possible Causes
  • ELAC-2 [2CE2]
  • wiring of the ACS2 signal from the ELAC2 COM side to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-90-00-810-801-A
Failure of an Alternating Current Supply (ACS)
ASM 279303
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-90-00-740-062-A
A. Test
Do the BITE Test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-90-00-810-057-A
A. If the test gives the maintenance messages:
L G AIL POS XDCR 33CE1
and
R B AIL POS XDCR 33CE4
   (1) At the ELAC2 receptacle, do a check of the resistance and of the insulation between the pin AA/14A and the pin AA/14B (15 to 250 ohms) ASM 279303.
     (a) If the resistance values are in the specified limits:
     (b) If the resistance is less than 15 ohms:
       1 Do the trouble shooting procedure (Ref. TSM TASK 27-90-00-810-801).
       2 Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
     (c) If the resistance is more than 250 ohms:
       1 Do a check and repair the wiring of the ACS2 signal from the ELAC2 COM side to the first terminal block ASM 279303.
       2 Install the ELAC2 AMM 27-93-34-400-001.
Subtask 27-90-00-740-068-A
B. Do the test given in Para. 3.