Loss of the ACS2 Signal of the SEC3 COM side
TASK 27-90-00-810-805-A
Loss of the ACS2 Signal of the SEC3 COM side
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-90-00-740-056-A 4. Fault Isolation
Subtask 27-90-00-810-054-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:51 UTC
Loss of the ACS2 Signal of the SEC3 COM side
1. Possible Causes
- SEC-3 [1CE3]
- wiring of the ACS2 signal from the SEC3 COM side to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-90-00-810-801-A | Failure of an Alternating Current Supply (ACS) |
| ASM 279404 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-90-00-740-056-A 4. Fault Isolation
Subtask 27-90-00-810-054-A
A. If the test gives the maintenance messages:
L SPLR1 POS XDCR 31CE1
and
R SPLR1 POS XDCR 31CE2
(a) If the resistance values are in the specified limits:
1 Do the trouble shooting procedure (Ref. TSM TASK 27-90-00-810-801).
2 Replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(c) If the resistance is more than 250 ohms:
1 Do a check and repair the wiring of the ACS2 signal from the SEC3 COM side to the first terminal block ASM 279404.
2 Install the SEC3 AMM 27-94-34-400-001.
Subtask 27-90-00-740-057-A L SPLR1 POS XDCR 31CE1
and
R SPLR1 POS XDCR 31CE2
- remove the SEC3 AMM 27-94-34-000-001.
(a) If the resistance values are in the specified limits:
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
1 Do the trouble shooting procedure (Ref. TSM TASK 27-90-00-810-801).
2 Replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(c) If the resistance is more than 250 ohms:
1 Do a check and repair the wiring of the ACS2 signal from the SEC3 COM side to the first terminal block ASM 279404.
2 Install the SEC3 AMM 27-94-34-400-001.
B. Do the test given in Para. 3.