Loss of the ACS2 Signal of the SEC1 MON Side
TASK 27-90-00-810-803-A
Loss of the ACS2 Signal of the SEC1 MON Side
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-90-00-740-052-A 4. Fault Isolation
Subtask 27-90-00-810-052-B
[Rev.8 from Aug 2018]
2026.04.04 04:39:14 UTC
Loss of the ACS2 Signal of the SEC1 MON Side
1. Possible Causes
- SEC-1 [1CE1]
- wiring of the ACS2 signal from the SEC1 MON side to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-90-00-810-801-A | Failure of an Alternating Current Supply (ACS) |
| ASM 279402 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-90-00-740-052-A 4. Fault Isolation
Subtask 27-90-00-810-052-B
A. If the test gives the maintenance messages:
L SPLR4 POS XDCR 31CE7
and
R SPLR4 POS XDCR 31CE8
(a) If the resistance values are in the specified limits:
1 Do the trouble shooting procedure (Ref. TSM TASK 27-90-00-810-801).
2 Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(c) If the resistance is more than 250 ohms:
1 Do a check and repair the wiring of the ACS2 signal from the SEC1 MON side to the first terminal block ASM 279402.
2 Install the SEC1 AMM 27-94-34-400-001.
Subtask 27-90-00-740-053-A L SPLR4 POS XDCR 31CE7
and
R SPLR4 POS XDCR 31CE8
- remove the SEC1 AMM 27-94-34-000-001.
(a) If the resistance values are in the specified limits:
- replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
1 Do the trouble shooting procedure (Ref. TSM TASK 27-90-00-810-801).
2 Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(c) If the resistance is more than 250 ohms:
1 Do a check and repair the wiring of the ACS2 signal from the SEC1 MON side to the first terminal block ASM 279402.
2 Install the SEC1 AMM 27-94-34-400-001.
B. Do the test given in Para. 3.