Failure of the Right Spoiler 1 Position Transducer
TASK 27-60-00-810-813-A
Failure of the Right Spoiler 1 Position Transducer
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-60-00-860-056-A
Subtask 27-60-00-810-062-B
[Rev.8 from Aug 2018]
2026.04.04 04:27:42 UTC
Failure of the Right Spoiler 1 Position Transducer
1. Possible Causes
- SERVO CTL-SPLR1, R G [31CE2]
wiring of the POS XDCR SPLY signal from the servo control (31CE2) to the first terminal block wiring of the POS XDCR V1, V2 signals from the servo control (31CE2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-90-00-810-805-A | Loss of the ACS2 Signal of the SEC3 COM side |
| AMM 27-64-51-000-004 | Removal of the Spoiler Servo Control |
| AMM 27-64-51-400-004 | Installation of the Spoiler Servo Control |
| ASM 279404 | |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 29-10-00-863-001 | Pressurize the Green Hydraulic System with a Hydraulic Ground Power-Cart |
| AMM 29-10-00-864-001 | Depressurize the Green Hydraulic System |
Subtask 27-60-00-860-056-A
A. Job Set-Up
(1) Pressurize the Green hydraulic system AMM 29-10-00-863-001.
(2) Pull the speedbrake control lever (7CE) up to the armed position on the panel 11VU.
Subtask 27-60-00-740-056-A (1) Pressurize the Green hydraulic system AMM 29-10-00-863-001.
(2) Pull the speedbrake control lever (7CE) up to the armed position on the panel 11VU.
B. Test
(1) Do the BITE test of the EFCS (Ground scanning) AMM 27-96-00-740-001.
(a) If the ground scanning gives the maintenance message:
R SPLR 1 POS XDCR 31CE2
R SPLR 1 POS XDCR 31CE2
L SPLR 1 POS XDCR 31CE1
Subtask 27-60-00-860-057-A (1) Do the BITE test of the EFCS (Ground scanning) AMM 27-96-00-740-001.
(a) If the ground scanning gives the maintenance message:
R SPLR 1 POS XDCR 31CE2
- refer to the Para. Fault Isolation.
R SPLR 1 POS XDCR 31CE2
L SPLR 1 POS XDCR 31CE1
- refer to this procedure (Ref. TSM TASK 27-90-00-810-805).
C. Put the aircraft back to its initial configuration
(1) Depressurize the Green hydraulic system AMM 29-10-00-864-001.
(2) Disarm the speedbrake control lever (7CE) on the panel 11VU.
4. Fault Isolation(1) Depressurize the Green hydraulic system AMM 29-10-00-864-001.
(2) Disarm the speedbrake control lever (7CE) on the panel 11VU.
Subtask 27-60-00-810-062-B
A. If the BITE test gives the maintenance message:
R SPLR 1 POS XDCR 31CE2
Subtask 27-60-00-740-057-A R SPLR 1 POS XDCR 31CE2
- replace the SERVO CTL-SPLR1, R G [31CE2] , AMM 27-64-51-000-004 and AMM 27-64-51-400-004.
NOTE: The resistance of primary and secondary windings must be between 30 ohms and 500 ohms.
(1) If the fault continues: - do a check and repair the
wiring of the POS XDCR SPLY signal from the servo control (31CE2) to the first terminal block , ASM 279404.
- do a check and repair the
wiring of the POS XDCR V1, V2 signals from the servo control (31CE2) to the first terminal block , ASM 279404.
B. Do the test given in Para. 3.