Failure of the Right Spoiler 1 Position Transducer


TASK 27-60-00-810-813-A
Failure of the Right Spoiler 1 Position Transducer


1. Possible Causes
  • SERVO CTL-SPLR1, R G [31CE2]
  • wiring of the POS XDCR SPLY signal from the servo control (31CE2) to the first terminal block
  • wiring of the POS XDCR V1, V2 signals from the servo control (31CE2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-90-00-810-805-A
Loss of the ACS2 Signal of the SEC3 COM side
AMM 27-64-51-000-004
Removal of the Spoiler Servo Control
AMM 27-64-51-400-004
Installation of the Spoiler Servo Control
ASM 279404
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AMM 29-10-00-863-001
Pressurize the Green Hydraulic System with a Hydraulic Ground Power-Cart
AMM 29-10-00-864-001
Depressurize the Green Hydraulic System
3. Fault Confirmation
Subtask 27-60-00-860-056-A
A. Job Set-Up
   (1) Pressurize the Green hydraulic system AMM 29-10-00-863-001.
   (2) Pull the speedbrake control lever (7CE) up to the armed position on the panel 11VU.
Subtask 27-60-00-740-056-A
B. Test
   (1) Do the BITE test of the EFCS (Ground scanning) AMM 27-96-00-740-001.
     (a) If the ground scanning gives the maintenance message:
R SPLR 1 POS XDCR 31CE2
  • refer to the Para. Fault Isolation.
     (b) If the ground scanning gives the maintenance messages:
R SPLR 1 POS XDCR 31CE2
L SPLR 1 POS XDCR 31CE1
Subtask 27-60-00-860-057-A
C. Put the aircraft back to its initial configuration
   (1) Depressurize the Green hydraulic system AMM 29-10-00-864-001.
   (2) Disarm the speedbrake control lever (7CE) on the panel 11VU.
4. Fault Isolation
Subtask 27-60-00-810-062-B
A. If the BITE test gives the maintenance message:
R SPLR 1 POS XDCR 31CE2
NOTE: The resistance of primary and secondary windings must be between 30 ohms and 500 ohms.
   (1) If the fault continues:
  • do a check and repair the wiring of the POS XDCR SPLY signal from the servo control (31CE2) to the first terminal block, ASM 279404.
   (2) If the fault continues:
  • do a check and repair the wiring of the POS XDCR V1, V2 signals from the servo control (31CE2) to the first terminal block, ASM 279404.
Subtask 27-60-00-740-057-A
B. Do the test given in Para. 3.