Loss of the Signal of the Right Elevator Position Transducer (MON) by the SEC 2
TASK 27-30-00-810-838-A
Loss of the Signal of the Right Elevator Position Transducer (MON) by the SEC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-30-00-700-108-A
Subtask 27-30-00-810-079-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:33 UTC
Loss of the Signal of the Right Elevator Position Transducer (MON) by the SEC 2
1. Possible Causes
- SEC-2 [1CE2]
wiring of the POS XDCR MON (ANI 2-2) signal from the SEC 2 (1CE2) MON part to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-90-00-810-822-A | Loss of the ACS1 Signal of the SEC2 MON Side |
| ASM 279408 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-30-00-700-108-A
A. Test
(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
(a) If the ground scanning gives the maintenance message:
SEC2 OR WIRING FROM R ELEV POS MON XDCR
SEC2 OR WIRING FROM L B ELEV MODE XDCR 34CE3
SEC2 OR WIRING FROM L ELEV POS MON XDCR
SEC2 OR WIRING FROM R B ELEV MODE XDCR 34CE4
SEC2 OR WIRING FROM R ELEV POS MON XDCR
SEC2 MON OR INPUT OF THS ACTR XDCR3 9CE
4. Fault Isolation(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
NOTE: Before you start the operational test procedure release the FLT CTL/ELAC 1 and FLT CTL/ELAC 2 pushbutton switches (on these pushbutton switches the OFF legends come on).
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001. (a) If the ground scanning gives the maintenance message:
SEC2 OR WIRING FROM R ELEV POS MON XDCR
- refer to Para. Fault Isolation.
SEC2 OR WIRING FROM L B ELEV MODE XDCR 34CE3
SEC2 OR WIRING FROM L ELEV POS MON XDCR
SEC2 OR WIRING FROM R B ELEV MODE XDCR 34CE4
SEC2 OR WIRING FROM R ELEV POS MON XDCR
SEC2 MON OR INPUT OF THS ACTR XDCR3 9CE
- do this trouble shooting procedure (Ref. TSM TASK 27-90-00-810-822).
Subtask 27-30-00-810-079-A
A. If the test gives the maintenance message:
SEC2 OR WIRING FROM R ELEV POS MON XDCR
Subtask 27-30-00-700-109-A SEC2 OR WIRING FROM R ELEV POS MON XDCR
- Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- Do a check and repair the
wiring of the POS XDCR MON (ANI 2-2) signal from the SEC 2 (1CE2) MON part to the first terminal block ASM 279408.
B. Do the tests given in Para. 3.