W DOC AIRBUS | TSM A320F

Failure of the Left Elevator Position MON Transducer


TASK 27-30-00-810-803-A
Failure of the Left Elevator Position MON Transducer


1. Possible Causes
  • XDCR UNIT-ELEV POS, L [49CE1]
  • wiring of the POS RVDT MON SPLY signal
  • wiring of the POS RVDT MON V1, V2 signals
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-90-00-810-820-A
Loss of the ACS1 Signal of the ELAC1 MON Side and SEC1 MON Side
TSM TASK 31-32-00-810-933-A
Failure of the Analog Links
AMM 27-92-13-000-001
Removal of the Elevator Position Transducer-Unit
AMM 27-92-13-400-001
Installation of the Elevator Position Transducer-Unit
ASM 279307
ASM 279407
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-30-00-700-122-A
A. Test
   (1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
   (2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
     (a) If the ground scanning gives the maintenance message:
L ELEV POS MON XDCR OF ELAC1/SEC1
  • refer to Para. Fault Isolation.
     (b) If the ground scanning gives at least two maintenance messages of the list below:
L ELEV POS MON XDCR OF ELAC1/SEC1
L G ELEV MODE XDCR 34CE1
R ELEV POS MON XDCR OF ELAC1/SEC1
R Y ELEV MODE XDCR 34CE2
THS ACTR XDCR2 MON 9CE
4. Fault Isolation
Subtask 27-30-00-810-086-C
A. If the test gives the maintenance message L ELEV POS MON XDCR OF ELAC1/SEC1
  • disconnect and cross the electrical connectors of the elevator position transducer unit (49CE1) ASM 279307 and do the test given in Para. 3.
NOTE: After the test connect the electrical connectors on their initial plugs.
   (1) If the fault continues:
   (2) If the test gives the maintenance message L ELEV POS MON XDCR OF ELAC2/SEC2:
NOTE: The resistance of primary and secondary windings must be between 30 ohms and 500 ohms.
   (3) If the test gives the maintenance message L ELEV POS MON XDCR OF ELAC1/SEC1
     (a) Do a check of the wiring of the POS RVDT MON SPLY signal from the transducer unit (49CE1) plug B to the first terminal block ASM 279307:
  • if there is continuity, see Para. (b)
  • if there is no continuity, repair the above wiring.
     (b) Do a check and repair the wiring of the POS RVDT MON V1, V2 signals from the transducer unit (49CE1), plug B to the first terminal block ASM 279307.
Subtask 27-30-00-700-123-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:30 UTC