W DOC AIRBUS | TSM A320F

Failure of the Right Blue Aileron Servo Control Position Transducer


TASK 27-10-00-810-826-A
Failure of the Right Blue Aileron Servo Control Position Transducer


1. Possible Causes
  • SERVO CTL-R AILERON, OUTBD B [33CE4]
  • wiring of the POS XDCR SPLY signal from the servo control (33CE4) to the first terminal block
  • wiring of the POS XDCR, V11, V12, V21, V22 signal from the servo control (33CE4) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-90-00-810-808-A
Loss of the ACS2 Signal of the ELAC2 COM Side
AMM 27-14-51-000-001
Removal of the Aileron Servo Control
AMM 27-14-51-400-001
Installation of the Aileron Servo Control
ASM 279303
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-10-00-700-087-A
A. Test
   (1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
     (a) If the ground scanning gives the maintenance message:
R B AIL POS XDCR 33CE4
  • refer to the Para. Fault Isolation.
     (b) If the ground scanning gives the maintenance messages:
R B AIL POS XDCR 33CE4
L G AIL POS XDCR 33CE1
4. Fault Isolation
Subtask 27-10-00-810-075-A
A. If the test gives the maintenance message:
R B AIL POS XDCR 33CE4
NOTE: The resistance of primary (pins A/B and A/C) and secondary (pins A/A and A/P, pins A/R and A/D) windings of the transducer must be between 30 ohms and 500 ohms. The insulation must be more than 10 Mohms.
These values are given for information only. You can use these values to do checks of the component electrical part or of the wiring before you replace the component. But by this procedure, the check of the component mechanical part is not done.
For primary winding (power supply):
  • if you do the resistance check from the avionics compartment, you must disconnect the transducer of the Left Green Aileron Servo Control.
   (1) If the fault continues:
     (a) Do a check of the wiring of the POS XDCR SPLY signal from the servo control (33CE4) to the first terminal block, ASM 279303:
  • if there is no continuity, repair the wiring
  • if there is continuity, see Para. (b).
     (b) Do a check and repair the wiring of the POS XDCR, V11, V12, V21, V22 signal from the servo control (33CE4) to the first terminal block, ASM 279303.
Subtask 27-10-00-700-088-A
B. Do the test given in Para. 3.