DEU-B Inoperative
TASK 26-17-00-810-819-A
DEU-B Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 26-17-00-710-080-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 26-17-00-810-106-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-860-065-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:22 UTC
DEU-B Inoperative
1. Possible Causes
DEU-B (300RHx)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 23-73-00-810-827-A | DEU-B - Fault in DEU-B 300RHx with connected systems/devices |
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
Subtask 26-17-00-710-080-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 26-17-00-810-106-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
Subtask 26-17-00-810-117-A ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message TEST OK, no other maintenance action is necessary.
Subtask 26-17-00-810-118-A ** ON A/C NOT FOR ALL C. If the test gives the maintenance message DEU-B(FIN):
Subtask 26-17-00-710-086-A ** ON A/C NOT FOR ALL - do the trouble shooting procedure (Ref. TSM TASK 23-73-00-810-827) for the related
DEU-B (300RHx)
D. Do the test as given in the Para. 3.
5. Close-upSubtask 26-17-00-860-065-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.