Cargo-Compartment Smoke Warning(s) without Fire
TASK 26-16-00-810-805-A
Cargo-Compartment Smoke Warning(s) without Fire
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 26-16-00-710-054-A
Subtask 26-16-00-810-059-A
Subtask 26-16-00-860-054-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:18 UTC
Cargo-Compartment Smoke Warning(s) without Fire
1. Possible Causes
- CIDS-SDF software
- oil leak of the APU
environmental conditions such as humidity, dust, etc.
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 21-00-00-810-801-A | Oil in the Air Conditioning System |
| AMM 12-33-21-618-001 | Pre-conditioning through the LP Ground Connection |
| AMM 26-16-00-910-801 | Report the Cargo-Compartment Smoke Warning Event |
Subtask 26-16-00-710-054-A
A. Test
(1) Some CIDS-SDF software can cause a spurious fault message for the smoke alarm to occur (Refer to TFU 23.73.00.101).
(2) Make sure that:
(a) There was no real smoke condition in the related area.
(b) There was no other cause, such as smoke source external to the aircraft, which could cause the smoke warning.
(c) The APU (Auxiliary Power Unit) operated during the smoke warning.
(3) Do the pre-conditioning of the air conditioning system with the APU AMM 12-33-21-618-001.
4. Fault Isolation(1) Some CIDS-SDF software can cause a spurious fault message for the smoke alarm to occur (Refer to TFU 23.73.00.101).
(2) Make sure that:
(a) There was no real smoke condition in the related area.
(b) There was no other cause, such as smoke source external to the aircraft, which could cause the smoke warning.
(c) The APU (Auxiliary Power Unit) operated during the smoke warning.
(3) Do the pre-conditioning of the air conditioning system with the APU AMM 12-33-21-618-001.
Subtask 26-16-00-810-059-A
A. If you smell fumes in the cabin during the pre-conditioning with the APU:
(1) Do the troubleshooting procedure for the oil in the air conditioning system (Ref. TSM TASK 21-00-00-810-801).
Subtask 26-16-00-810-135-A ** ON A/C NOT FOR ALL 5. Close-up(1) Do the troubleshooting procedure for the oil in the air conditioning system (Ref. TSM TASK 21-00-00-810-801).
NOTE: This fault can be caused by a smoke event because of an oil leak of the APU or environmental conditions such as humidity, dust, etc.
Subtask 26-16-00-860-054-A
A. Put the aircraft back to its initial configuration.