Overcurrent on the GEN 2 Because of a Failure of the BTC 2 Status Circuit


TASK 24-20-00-810-891-A
Overcurrent on the GEN 2 Because of a Failure of the BTC 2 Status Circuit


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-20-00-810-919-A
Overload on the Electrical Network of the Generator 2
ASM 242203
AMM 24-22-34-000-001
Removal of the GCU-1(2)
AMM 24-22-34-400-001
Installation of the GCU-1(2)
AMM 24-22-55-000-001
Removal of the Contactors
AMM 24-22-55-400-002
Installation of the Contactors
AMM 24-41-00-740-002
Operational Check of the GAPCU via the CFDS
3. Fault Confirmation
Subtask 24-20-00-740-094-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
NOTE: If the CFDS message GEN2 OVERCURRENT + GCU2 (1XU2)/ BTC2 (11XU2) comes into view, do the trouble shooting for an IDG 2 overcurrent condition with the procedure (Ref. TSM TASK 24-20-00-810-919).
     (a) If the BITE test gives the message TEST FAILED:
  • do the trouble shooting given in Para 4.A.
     (b) If the BITE test gives the message TEST PASSED:
  • do the trouble shooting given in Para 4.B.
4. Fault Isolation
Subtask 24-20-00-810-197-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the message TEST FAILED:
  • push the line key adjacent to the TEST FAILED message.
   (1) If the maintenance message GCU2 (1XU2) comes into view:
Subtask 24-20-00-810-198-A ** ON A/C NOT FOR ALL
B. If the BITE test gives the message TEST PASSED:
  • do a check of the coil return wiring for a short circuit or a short to ground between pin B/5 of the BTC 2 and pin A/9A of the GCU 2 ASM 242203.
   (1) If the wiring is not correct:
  • repair or replace as necessary.
   (2) If the wiring is correct:
  • do a check of the BTC 2 auxiliary contact for correct operation between pin B/27 and pin B/29 ASM 242203.
     (a) If there is no continuity:
     (b) If there is continuity:
  • do a check of the wiring for a short circuit or a short to ground between pin B/29 of the BTC 2 and pin A/4C of the GCU 2 ASM 242203.
       1 If the wiring is not correct:
  • repair or replace as necessary.
       2 If the wiring is correct:
Subtask 24-20-00-740-095-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.