Overload on the Electrical Network of the Generator 2


TASK 24-20-00-810-919-A
Overload on the Electrical Network of the Generator 2


1. Possible Causes
  • C/B-AFT GALLEY/FEEDER A [3MC]
  • C/B-FWD GALLEY/FEEDER D [2MC]
  • IDG-ENG 2 [4000XU2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
ASM 245103
AMM 71-00-00-710-003
Engine Automatic Start
AMM 71-00-00-710-028
Engine Shutdown
AMM 71-00-00-710-043
Normal Engine Automatic Start Procedure
AMM 71-00-00-860-814
Shutdown of the Engine
AMM 71-00-00-860-823
Start the Engine (Normal Automatic Start)
3. Fault Confirmation
Subtask 24-20-00-860-181-A ** ON A/C NOT FOR ALL
A. Job Set-up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits from the external power AMM 24-41-00-861-002.
   (2) On the ELEC panel 35VU, make sure that the ELEC/GEN 2 pushbutton switch (3XU2) is pushed.
   (3) On the ELEC panel 35VU, make sure that the ELEC/GALLEY pushbutton switch (2XA) is pushed (the OFF legend is off).
Subtask 24-20-00-700-120-B ** ON A/C NOT FOR ALL
B. Test
   (1) Start the engine 2 AMM 71-00-00-710-003.
   (2) On the upper ECAM DU, the warning GEN 2 OVERLOAD is shown.
4. Fault Isolation
Subtask 24-20-00-865-063-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAE02
** ON A/C NOT FOR ALL
123VUTR2/214XP/SPLY2PU2AB04
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
123VUBUS 2/204XP/SPLY3XN2AB02
123VUBUS 2/231XP-A/SPLY5XN2AB01
123VUAC ESS/BUS ON/BUS 22XCAC01
123VUBUS 2/212XP/SPLY10XNAD03
123VUBUS 2/202XP/SPLY1XN2AD02
123VUANTI ICE/R/WHSLD1DG2AF03
123VUBUS 2/210XP/SPLY7XN2AF02
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAC04
Subtask 24-20-00-810-210-B ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
  • In the AC power center panel 123VU, do a check of the circuit breakers 3MC and 2MC.
   (1) If the circuit breakers 3MC and/or 2MC are open:
  • Replace C/B-AFT GALLEY/FEEDER A [3MC] and/or C/B-FWD GALLEY/FEEDER D [2MC] .
   (2) If the circuit breakers 3MC and 2MC are closed:
  • On the AC power center panel 123VU, do a check of the status of the circuit breakers 5XN2, 3XN2, 7XN2, 1DG2, 2XC, 2HQ, 1XN2, 2PU2, 10XN and 3801GX.
     (a) If one or more circuit breaker(s) is(are) open:
  • Do a check of the loads downstream of the open circuit breaker(s) for a short to ground or a defective component.
     (b) If all the circuit breakers are closed:
Subtask 24-20-00-810-210-F ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
  • in the AC power center panel 123VU, do a check of the circuit breakers 3MC and 2MC.
   (1) If the circuit breakers 3MC and/or 2MC are open:
  • replace the [3MC] and/or the [2MC] .
   (2) If the circuit breakers 3MC and 2MC are closed:
  • on the AC power center panel 123VU, do a check of the status of the circuit breakers 5XN2, 3XN2, 7XN2, 1DG2, 2XC, 2HQ, 1XN2, 2PU2, 10XN and 3801GX.
     (a) If one or more circuit breaker(s) is(are) open:
  • do a check of the loads downstream of the open circuit breaker(s) for a short to ground or a defective component.
     (b) If all the circuit breakers are closed:
Subtask 24-20-00-810-160-D ** ON A/C NOT FOR ALL
C. Do a check of the AC/DC main power center 120VU:
  • Open the AC/DC main power center 120VU and do a check of the wiring for a short circuit or a short to ground between downstream of the GLC 2 (load side) and the loads ASM 245103.
   (1) If the wiring is not correct:
  • Repair or replace as necessary.
   (2) If the wiring is correct:
  • Do a check of the feeders for a short to ground, a short circuit or a related defective equipement between the pins 4, 5 and 6 of the generator 2 contactor module (30XN2) and the load side ASM 245103.
     (a) If there is a short to ground:
  • Repair or replace as necessary.
     (b) If there is no short to ground:
  • Energize the aircraft electrical network from the external power AMM 24-41-00-861-002
  • Start the engine 2 only AMM 71-00-00-710-043 and close one by one the circuit breakers until the warning GEN 2 OVERLOAD is shown. Repair the wiring or the component of the defective circuit.
Subtask 24-20-00-710-138-B ** ON A/C NOT FOR ALL
D. Do this test to make sure that the failure is repaired:
   (1) Make sure that the circuit breakers are closed (if the circuit breakers are not closed, close them).
   (2) Energize the aircraft electrical circuit from the external power AMM 24-41-00-861-002.
   (3) On the ELEC panel 35VU, make sure that the ELEC/GALLEY pushbutton switch is pushed.
   (4) Start engine 2 AMM 71-00-00-860-823.
   (5) After five minutes, make sure that, on the upper ECAM DU, the warning GEN 2 OVERLOAD is not shown.
   (6) Stop engine 2 AMM 71-00-00-860-814.
Subtask 24-20-00-710-138-F ** ON A/C NOT FOR ALL
D. Do this test to make sure that the failure is repaired:
   (1) Make sure that the circuit breakers are closed (if the circuit breakers are not closed, close them).
   (2) Energize the aircraft electrical circuit from the external power AMM 24-41-00-861-002.
   (3) On the ELEC panel 35VU, make sure that the ELEC/GALLEY pushbutton switch is pushed.
   (4) Start the engine 2 AMM 71-00-00-710-003.
   (5) After five minutes, make sure that, on the upper ECAM DU, the warning GEN 2 OVERLOAD is not shown.
   (6) Stop the engine 2 AMM 71-00-00-710-028.
5. Close-up
Subtask 24-20-00-860-163-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) De-energize the aircraft electrical circuits from the external power AMM 24-41-00-862-002.