EVAC - No function of the EVAC indication on 2064VU panel
TASK 23-73-00-810-904-A
EVAC - No function of the EVAC indication on 2064VU panel
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-297-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-613-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:56 UTC
EVAC - No function of the EVAC indication on 2064VU panel
1. Possible Causes
- 2064VU
- DEU-B
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 23-73-00-810-861-A | CIDS - Fault in all CIDS-related cabin functions |
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237310 | |
| AMM 23-73-47-000-001 | Removal of the Decoder/Encoder Unit B (300RH) |
| AMM 23-73-47-400-001 | Installation of the Decoder/Encoder Unit B (300RH) |
Subtask 23-73-00-710-297-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-613-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-617-B ** ON A/C NOT FOR ALL B. If the EVAC indication on one 2064VU panel does not come on:
Subtask 23-73-00-810-618-A ** ON A/C NOT FOR ALL - do a check for approx. 28V DC at the related 2064VU panel, pin 3.
ASM 237310
- replace the related panel 2064VU .
- do a check for approx. 28V DC at the related DEU-B, connector C pin 22.
ASM 237310
- replace the related DEU-B AMM 23-73-47-000-001 and AMM 23-73-47-400-001.
- do a check and repair the wiring between:
the related DEU-B, connector C pin 22 and the related 2064VU panel, pin 3.
ASM 237310
- do a check of the wiring between:
the related DEU-B connector C pin 20 and the related 2064VU panel, pin 2.
ASM 237310
C. If the EVAC indication on all 2064VU panels do not come on:
Subtask 23-73-00-710-301-A ** ON A/C NOT FOR ALL - do the trouble shooting procedure.
(Ref. TSM TASK 23-73-00-810-861)
D. Do the test given in Para. 3.A.