EVAC - No function of the EVAC indication on 2064VU panel


TASK 23-73-00-810-904-A
EVAC - No function of the EVAC indication on 2064VU panel


1. Possible Causes
  • 2064VU
  • DEU-B
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 23-73-00-810-861-A
CIDS - Fault in all CIDS-related cabin functions
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237310
AMM 23-73-47-000-001
Removal of the Decoder/Encoder Unit B (300RH)
AMM 23-73-47-400-001
Installation of the Decoder/Encoder Unit B (300RH)
3. Fault Confirmation
Subtask 23-73-00-710-297-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up test through the CFDS.
AMM 23-73-00-740-005
4. Fault Isolation
Subtask 23-73-00-810-613-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-617-B ** ON A/C NOT FOR ALL
B. If the EVAC indication on one 2064VU panel does not come on:
  • do a check for approx. 28V DC at the related 2064VU panel, pin 3.
    ASM 237310
   (1) If there are approx. 28V DC:
  • replace the related panel 2064VU .
   (2) If there not are approx. 28V DC:
  • do a check for approx. 28V DC at the related DEU-B, connector C pin 22.
    ASM 237310
     (a) If there are approx. 28V DC:
     (b) If there are not approx. 28V DC:
  • do a check and repair the wiring between:
    the related DEU-B, connector C pin 22 and the related 2064VU panel, pin 3.
    ASM 237310
     (c) If the fault continue:
  • do a check of the wiring between:
    the related DEU-B connector C pin 20 and the related 2064VU panel, pin 2.
    ASM 237310
Subtask 23-73-00-810-618-A ** ON A/C NOT FOR ALL
C. If the EVAC indication on all 2064VU panels do not come on:
Subtask 23-73-00-710-301-A ** ON A/C NOT FOR ALL
D. Do the test given in Para. 3.A.