CIDS - Fault in all CIDS-related cabin functions
TASK 23-73-00-810-861-A
CIDS - Fault in all CIDS-related cabin functions
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-075-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-076-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:53 UTC
CIDS - Fault in all CIDS-related cabin functions
1. Possible Causes
- DIR-CIDS, 1 [101RH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-075-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
(2) Operate some CIDS related cabin systems.
Subtask 23-73-00-710-075-B ** ON A/C NOT FOR ALL (1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
(2) Operate some CIDS related cabin systems.
A. Test
(1) Do the CIDS Interface and Power-Up test through the CFDS.
AMM 23-73-00-740-005
(2) Operate some CIDS-related cabin systems.
4. Fault Isolation(1) Do the CIDS Interface and Power-Up test through the CFDS.
AMM 23-73-00-740-005
(2) Operate some CIDS-related cabin systems.
Subtask 23-73-00-810-076-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-086-D ** ON A/C NOT FOR ALL B. If the CIDS BITE test result is no fault message, but you cannot operate the CIDS-related systems:
Subtask 23-73-00-810-086-F ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open.
- make sure that the EMER LT (4WL) switch is set to the OFF position.
- open these CBs:
49VU: 150RH COM DIR ESS/1,
49VU: 157RH COM DIR ESS/2,
121VU: 151RH CIDS/DIR NORM/1,
121VU: 156RH CIDS/DIR NORM/2. - wait for approx. 10s and close the CBs 156RH and 157RH.
- stop for approx. 120s,
- do the CIDS BITE test again (start with step 4.) and operate some CIDS-related cabin systems.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001
B. If the CIDS Interface and Power-Up test result is no fault message, but you cannot operate the CIDS-related systems:
Subtask 23-73-00-810-086-G ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open.
- open these CBs:
49VU: 150RH COM/CIDS/DIR ESS/1,
49VU: 157RH COM/CIDS/DIR ESS/2,
49VU: 15WH AIR COND/CIDS/SDF/DIR1 ESS,
49VU: 18WH AIR COND/CIDS/SDF/DIR2 ESS,
120VU: 151RH COM NAV/CIDS/DIR NORM/1,
120VU: 156RH COM NAV/CIDS/DIR NORM/2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2,
122VU: 17WH AIR COND/CIDS/SDF/DIR NORM/1. - wait for approx. 10s and close the CBs 156RH, 157RH, 14WH and 18WH.
- stop for approx. 120s,
- do the CIDS Interface and Power-Up test again (start with step 4.) and operate some CIDS-related cabin systems.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001
B. If the CIDS Interface and Power-Up test result is no fault message, but you cannot operate the CIDS-related systems:
Subtask 23-73-00-810-087-A Subtask 23-73-00-710-216-A - make sure that at least one cabin door is open.
make sure that the EMER LT (4WL) switch is set to the OFF position. - open these CBs:
49VU: 150RH COM/CIDS/DIR ESS/1,
49VU: 157RH COM/CIDS/DIR ESS/2,
49VU: 15WH AIR COND/CIDS/SDF/DIR1 ESS,
49VU: 18WH AIR COND/CIDS/SDF/DIR2 ESS,
120VU: 151RH COM NAV/CIDS/DIR NORM/1,
120VU: 156RH COM NAV/CIDS/DIR NORM/2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2,
122VU: 17WH AIR COND/CIDS/SDF/DIR NORM/1. - wait for approx. 10s and close the CBs 156RH, 157RH, 14WH and 18WH.
- stop for approx. 120s,
- do the CIDS Interface and Power-Up test again (start with step 4.) and operate some CIDS-related cabin systems.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001
D. Do the test given in Para. 3.A.