W DOC AIRBUS | TSM A320F

DEU-B - Fault in all DEU-B with a connected handset


TASK 23-73-00-810-880-A
DEU-B - Fault in all DEU-B with a connected handset


1. Possible Causes
  • DIR-CIDS, 1 [101RH]
  • DIR-CIDS, 2 [102RH]
  • DEU-B 300RHxx
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 23-73-00-810-836-A
CIDS - Fault in the CIDS MID BUS L / Director 1
TSM TASK 23-73-00-810-837-A
CIDS - Fault in the CIDS MID BUS R / Director 1
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237310
ASM 237311
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 23-73-47-000-001
Removal of the Decoder/Encoder Unit B (300RH)
AMM 23-73-47-400-001
Installation of the Decoder/Encoder Unit B (300RH)
3. Fault Confirmation
Subtask 23-73-00-710-244-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 23-73-00-810-536-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-546-A ** ON A/C NOT FOR ALL
B. If the CIDS BITE test gives the maintenance messages:

on the ECAM:

CIDS 1 + 2 FAULT

on the CFDS:

ALL DEU-B WI HANDSET
DIRECTOR (1 or 2)
CIDS MID BUS L
CIDS MID BUS R
DEU-B 300RHxx (all installed DEU-Bs)

Subtask 23-73-00-810-547-A ** ON A/C NOT FOR ALL
C. If the CIDS BITE test gives the maintenance messages:

on the ECAM:

CIDS 1 + 2 FAULT

on the CFDS:

ALL DEU-B WI HANDSET
DEU-B 300RHxx (all DEU-Bs with a connected handset)

Subtask 23-73-00-810-548-A ** ON A/C NOT FOR ALL
D. If the CIDS BITE test gives the maintenance messages:

on the ECAM:

CIDS 1 + 2 FAULT

on the CFDS:

ALL DEU-B WI HANDSET
CIDS MID BUS L
CIDS MID BUS R
DEU-B 300RHxx (all installed DEU-Bs)

   (1) If the fault continues:
  • do a check and repair the wiring if necessary between:
    CB 162RH and connector A/8 of all DEU-B mounts ASM 237310 and ASM 237311.
     (a) If the fault continues:
Subtask 23-73-00-710-264-A ** ON A/C NOT FOR ALL
E. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:55 UTC