W DOC AIRBUS | TSM A320F

CIDS - Fault in the CIDS MID BUS R / Director 1


TASK 23-73-00-810-837-A
CIDS - Fault in the CIDS MID BUS R / Director 1


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237306
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 23-73-42-000-001
Removal of the Connection Box (208RH,308RH)
AMM 23-73-42-400-001
Installation of the Connection Box (208RH,308RH)
AMM 23-73-43-000-001
Removal of the Termination Box (209RH,309RH)
AMM 23-73-43-400-001
Installation of the Termination Box (209RH,309RH)
AMM 23-73-47-000-001
Removal of the Decoder/Encoder Unit B (300RH)
AMM 23-73-47-400-001
Installation of the Decoder/Encoder Unit B (300RH)
AMM 23-73-48-000-001
Removal of the DEU A/DEU B - Mount
AMM 23-73-48-400-001
Installation of the DEU A/DEU B - Mount
3. Fault Confirmation
Subtask 23-73-00-710-078-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS1/CIDS BUS test through the CFDS/MCDU.
   (2) Do the CIDS1/DEU-B test through the CFDS/MCDU.
Subtask 23-73-00-710-078-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up test through the CFDS.
AMM 23-73-00-740-005
4. Fault Isolation
Subtask 23-73-00-810-079-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-142-F ** ON A/C NOT FOR ALL
B. If the CIDS1/CIDS BUS test gives the maintenance message CIDS MID BUS R:
  • Make sure that at least one cabin door is open.
  • In the cockpit, on the overhead panel 25VU:
    Make sure that the EMER EXIT LT switch (4WL) is in the OFF position.
  • Remove the DIR-CIDS (101RH) AMM 23-73-34-000-001.
  • Close these CBs:
    49VU: 157RH (G02) CIDS/DIR 2/ESS,
    121VU:156RH (M07) CIDS/DIR 2/NORM.
  • Wait for approx. 120 s.
  • Do the CIDS2/CIDS BUS test through the CFDS/MCDU.
   (1) If the CIDS2/CIDS BUS test is OK:
   (2) If the fault continues:
  • Remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
  • During the installation of the DIR-CIDS, 1 (101RH) do not close these CBs:
    49VU: 157RH (G02) CIDS/DIR 2/ESS,
    121VU:156RH (M07) CIDS/DIR 2/NORM.
  • Install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
  • Do the CIDS1/CIDS BUS test through the CFDS/MCDU.
   (3) If the CIDS1/CIDS BUS test is OK:
   (4) If the fault continues:
  • Remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001.
  • Open these CBs:
    49VU: 153RH COM/CIDS/DEU B/ESS,
    120RH: 162RH COM NAV/CIDS/DEU B/NORM.
  • Make sure that the resistance (line to line) at DIR-CIDS (101RH) and (102RH) connector AA/A14 and connector AA/B14 is between approx. 80 and 200 ohms ASM 237306.
   (5) If the resistance (line to line) is between approx. 80 and 200 ohms:
  • Make sure that the resistance (line to GND) is not less than 50 ohms (short circuit) between:
    DIR-CIDS (101RH) and (102RH) connector AA/A14 and GND,
    DIR-CIDS (101RH) and (102RH) connector AA/B14 and GND ASM 237306.
     (a) If there is no short circuit:
       1 If the CIDS BITE test gives the maintenance message DEU-B 300RH6:
       2 If the CIDS BITE test gives the maintenance message CIDS MID BUS R:
     (b) If there is a short circuit:
       1 If there is no short circuit:
       2 If the fault continues:
  • Disconnect the electrical connector 7247VC2 from the DEU mount 2015VU2 AMM 23-73-48-000-001.
  • Do a check for a short circuit again.
         a If there is no short circuit:
         b If the fault continues:
  • Install the removed DEU-B [300RH6] AMM 23-73-47-400-001.
  • Reconnect the electrical connector to the DEU mount 2015VU2 AMM 23-73-48-400-001.
  • Remove the DEU-B [300RH4] AMM 23-73-47-000-001.
  • Do a check for a short circuit again.

  • b.1. If there is no short circuit:
  • Install a new DEU-B [300RH4] AMM 23-73-47-400-001.

  • b.2. If the fault continues:
  • Disconnect the electrical connector 7201VC4 from the DEU mount 2011VU4 AMM 23-73-48-000-001.
  • Do a check for a short circuit again.

  • b.2.1. If there is no short circuit:
  • Do a check for a short circuit at the disconnected connector 7201VC4 between pin 9 and GND (pin 11) and between pin 10 and GND (pin 11).

  • b.2.1.1. If there is a short circuit:
  • Repair the wiring between the DEU mount 2011VU4 and the DEU mount 2015VU2 ASM 237306.

  • b.2.1.2. If there is no short circuit:
  • Install a new DEU mount 2011VU4 AMM 23-73-48-400-001.

  • b.2.2. If there is a short circuit:
  • Install the removed DEU-B [300RH4] AMM 23-73-47-400-001.
  • Reconnect the electrical connector to the DEU mount 2011VU4 AMM 23-73-48-400-001.
  • Do the steps (4. B. (5) (b) 2 b) again for the subsequent DEU(s) and DEU mount(s) until the maintenance message stops: ASM 237306.
    DEU mount 2011VU2 .
   (6) If the resistance (line to line) is more than 200 ohms (open circuit):
  • disconnect the electrical connector 7247VC2 from the DEU mount 2015VU2 AMM 23-73-48-000-001.
  • Make sure that the resistance (line to line) is not more than 200 ohms (open circuit) between:
    DEU mount 2015VU2 pin A/1 and pin A/2.
     (a) If there is an open circuit:
     (b) If there is no open circuit:
  • Reconnect the electrical connector to the DEU mount 2015VU2 AMM 23-73-48-400-001.
  • Disconnect the electrical connector 7201VC2 from the DEU mount 2011VU2 AMM 23-73-48-000-001.
  • Do a check of the wiring (continuity-check) between:
    DIR-CIDS (101RH) connector AA/A14 and the connector 7201VC2 pin A/1,
    DIR-CIDS (101RH) connector AA/B14 and the connector 7201VC2 pin A/2.
       1 If there is no continuity:
  • Repair the wiring between the DIR-CIDS (101RH) and the connector 7201VC2 ASM 237306.
       2 If there is continuity:
  • Do a check of the wiring (continuity-check) between:
    DEU mount 2011VU2 pin A/1 and pin A/9 ,
    DEU mount 2011VU2 pin A/2 and pin A/10.
         a If there is no continuity:
         b If there is continuity:
  • Reconnect the connector 7201VC2 to the DEU mount 2011VU2 AMM 23-73-48-400-001.
  • Do the steps 4. B. (6) again for the subsequent DEU mounts until the maintenance message stops:
    DIR-CIDS (101RH) and DEU mount 2011VU4 /connector 7201VC4,
    DIR-CIDS (101RH) and DEU mount 2015VU2 /connector 7247VC2.
   (7) If the resistance (line to line) is less than 80 ohms (short circuit):
     (a) If there is no short circuit:
     (b) If there is a short circuit:
       1 If there is a short circuit:
  • Reconnect the electrical connector to the DEU mount 2015VU2 AMM 23-73-48-400-001.
  • Do the steps 4. B. (7) again for the subsequent DEU(s) and DEU mount(s) until the maintenance message stops: ASM 237306.
    DEU-B [300RH4] and DEU mount 2011VU4 ,
    DEU mount 2011VU2 .
       2 If there is no short circuit:
  • Do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306.
         a If there is a short circuit:
  • Repair the wiring between the related DEU mount 2011VUxx and the DEU mount 2015VUxx/2011VUxx ASM 237306.
         b If there is no short circuit:
Subtask 23-73-00-810-142-L ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message CIDS MID BUS R/ DIR1 (101RH):
  • make sure that at least one cabin door is open,
  • remove the DIR-CIDS (101RH) AMM 23-73-34-000-001,
  • close these CBs:
    49VU: 157RH COM/CIDS/ DIR ESS/ 2,
    49VU: 18WH AIR COND/ CIDS/SDF/ DIR 2 ESS,
    120VU: 156RH COM NAV/ CIDS/ DIR NORM/ 2,
    122VU: 14WH AIR COND/ CIDS/ SDF/ DIR NORM/ 2,
  • wait for approx. 120 s,
  • do the CIDS2 Interface and Power-Up Test via the CFDS/MCDU AMM 23-73-00-740-005.
   (1) If the test is OK:
   (2) If the fault continues:
  • remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
  • during the installation of the DIR-CIDS, 1 (101RH) do not close these CBs:
    49VU: 157RH COM/CIDS/ DIR ESS/ 2,
    49VU: 18WH AIR COND/ CIDS/SDF/ DIR 2 ESS,
    120VU: 156RH COM NAV/ CIDS/ DIR NORM/ 2,
    122VU: 14WH AIR COND/ CIDS/ SDF/ DIR NORM/ 2,
  • install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
  • Do the test given in Para. 3.
   (3) If the test is OK:
   (4) If the fault continues:
  • remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001.
  • open these CBs:
    49VU: 153RH COM/CIDS/DEU B/ESS
    120VU: 162RH COM NAV/CIDS/DEU B/NORM
  • make sure that the resistance (line to line) at DIR-CIDS (101RH) and (102RH) connector AA/A14 and connector AA/B14 is between approx. 80 and 140 ohms ASM 237306.
   (5) If the resistance (line to line) is between approx. 80 and 140 ohms:
  • make sure that the resistance (line to GND) is not less than 7 k ohms (short circuit) between:
    DIR-CIDS (101RH) and (102RH) connector AA/A14 and GND,
    DIR-CIDS (101RH) and (102RH) connector AA/B14 and GND. ASM 237306
     (a) If there is no short circuit:
  • remove the DEU-B [300RH6] AMM 23-73-47-000-001.
  • install the DIR-CIDS (101RH) and DIR-CIDS (102RH) AMM 23-73-34-400-001.
  • close these CBs:
    49VU: 153RH COM/CIDS/DEU B/ESS
    120VU: 162RH COM NAV/CIDS/DEU B/NORM
  • Do the test given in Para. 3.
       1 If the test gives the maintenance message DEU-B 300RH8:
       2 If the test gives the maintenance message CIDS MID BUS R/ DIR1 (101RH):
     (b) If there is a short circuit:
       1 If there is no short circuit:
       2 If the fault continues:
  • disconnect the electrical connector from the DEU TERMINATION BOX [309RH2] .
  • do a check for a short circuit again.
         a If there is no short circuit:
         b If the fault continues:
  • install the removed DEU-B [300RH8] AMM 23-73-47-400-001,
  • reconnect the electrical connector to the DEU TERMINATION BOX [309RH2] ASM 237306,
  • remove the DEU-B [300RH6] AMM 23-73-47-000-001,
  • do a check for a short circuit again.

  • b.1. If there is no short circuit:
  • install a new DEU-B [300RH6] AMM 23-73-47-400-001,
  • Do the test given in Para. 3.

  • b.2. If the fault continues:
  • disconnect the electrical connector from the DEU CONNECTION BOX [308RH6] ,
  • do a check for a short circuit again.

  • b.2.1. If there is no short circuit:
  • do a check for a short circuit at the disconnected connector between pin 9 and GND (pin 4) and between pin 10 and GND (pin 4).

  • b.2.1.1. If there is a short circuit:
  • repair the wiring between the DEU CONNECTION BOX [308RH6] and the DEU TERMINATION BOX [309RH2] ASM 237306.
  • Do the test given in Para. 3.

  • b.2.1.2. If there is no short circuit:
  • install a new DEU CONNECTION BOX [308RH2] AMM 23-73-42-400-001
  • Do the test given in Para. 3.

  • b.2.2. If there is a short circuit:
  • install the removed DEU-B [300RH6] AMM 23-73-47-400-001,
  • reconnect the electrical connector to the DEU CONNECTION BOX [308RH6] ,
  • do the steps (4. B. (5) (b) 2 b) again for the subsequent DEU(s) and DEU CONNECTION BOX(es) until the maintenance message stops: ASM 237306
    DEU CONNECTION BOX [308RH2] .
   (6) If the resistance (line to line) is more than 140 ohms (open circuit):
  • disconnect the electrical connector from the DEU TERMINATION BOX [309RH2] ,
  • make sure that the resistance (line to line) is not more than 140 ohms (open circuit) between:
    DEU TERMINATION BOX [309RH2] pin A/1 and pin A/2
     (a) If there is an open circuit:
     (b) If there is no open circuit:
  • reconnect the electrical connector to the DEU TERMINATION BOX [309RH2]
  • disconnect the electrical connector from the DEU CONNECTION BOX [308RH2] .
  • do a check of the wiring (continuity-check) between:
    DIR-CIDS (101RH) connector AA/A14 and the DEU TERMINATION BOX connector pin A/2,
    DIR-CIDS (101RH) connector AA/B14 and the DEU TERMINATION BOX connector pin A/1.
       1 If there is no continuity:
  • repair the wiring between the DIR-CIDS (101RH) and the connector ASM 237306.
  • Do the test given in Para. 3.
       2 If there is continuity:
  • do a check of the wiring (continuity-check) between:
    DEU CONNECTION BOX [308RH2] pin A/1 and pin A/9 ,
    DEU CONNECTION BOX [308RH2] pin A/2 and pin A/10.
         a If there is no continuity:
         b If there is continuity:
  • reconnect the connector to the DEU CONNECTION BOX [308RH2]
  • do the steps 4. B. (6) again for the subsequent DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops:
    DIR-CIDS (101RH) and DEU CONNECTION BOX [308RH6] /connector,
    DIR-CIDS (101RH) and DEU TERMINATION BOX [309RH2] /connector.
   (7) If the resistance (line to line) is less than 80 ohms (short circuit):
     (a) If there is no short circuit:
     (b) If there is a short circuit:
       1 If there is a short circuit:
  • reconnect the electrical connector to the DEU TERMINATION BOX [309RH2]
  • do the steps 4. B. (7) again for the subsequent DEU(s) and DEU CONNECTION BOX(es) until the maintenance message stops: ASM 237306
    DEU-B [300RH6] and DEU CONNECTION BOX [308RH6] ,
    DEU CONNECTION BOX [308RH2] ,
       2 If there is no short circuit:
  • do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306
         a If there is a short circuit:
  • repair the wiring between the related DEU CONNECTION BOX 308RHxx and the DEU CONNECTION/ TERMINATION BOX 308RHxx/309RHxx ASM 237306.
  • Do the test given in Para. 3.
         b If there is no short circuit:
Subtask 23-73-00-810-142-M ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message CIDS MID BUS R/ DIR1 (101RH):
  • make sure that at least one cabin door is open,
  • On the overhead-panel 25VU:
    make sure that the EMER EXIT LT switch (4WL) is in the OFF position,
  • remove the DIR-CIDS (101RH) AMM 23-73-34-000-001,
  • close these CBs:
    49VU: 157RH COM/CIDS/ DIR ESS/ 2,
    49VU: 18WH AIR COND/ CIDS/SDF/ DIR 2 ESS,
    120VU: 156RH COM NAV/ CIDS/ DIR NORM/ 2,
    122VU: 14WH AIR COND/ CIDS/ SDF/ DIR NORM/ 2,
  • wait for approx. 120 s,
  • do the CIDS2 Interface and Power-Up Test via the CFDS/MCDU AMM 23-73-00-740-005.
   (1) If the test is OK:
   (2) If the fault continues:
  • remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001,
  • during the installation of the DIR-CIDS, 1 (101RH) do not close these CBs:
    49VU: 157RH COM/CIDS/ DIR ESS/ 2,
    49VU: 18WH AIR COND/ CIDS/SDF/ DIR 2 ESS,
    120VU: 156RH COM NAV/ CIDS/ DIR NORM/ 2,
    122VU: 14WH AIR COND/ CIDS/ SDF/ DIR NORM/ 2,
  • install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
  • Do the test given in Para. 3.
   (3) If the test is OK:
   (4) If the fault continues:
  • remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001,
  • open these CBs:
    49VU: 153RH COM/CIDS/DEU B/ESS
    120VU: 162RH COM NAV/CIDS/DEU B/NORM
  • make sure that the resistance (line to line) at DIR-CIDS (101RH) and (102RH) connector AA/A14 and connector AA/B14 is between approx. 80 and 140 ohms ASM 237306.
   (5) If the resistance (line to line) is between approx. 80 and 140 ohms:
  • make sure that the resistance (line to GND) is not less than 7 k ohms (short circuit) between:
    DIR-CIDS (101RH) and (102RH) connector AA/A14 and GND,
    DIR-CIDS (101RH) and (102RH) connector AA/B14 and GND. ASM 237306
     (a) If there is no short circuit:
  • remove the DEU-B [300RH6] AMM 23-73-47-000-001,
  • install the DIR-CIDS (101RH) and DIR-CIDS (102RH) AMM 23-73-34-400-001.
  • close these CBs:
    49VU: 153RH COM/CIDS/DEU B/ESS
    120VU: 162RH COM NAV/CIDS/DEU B/NORM
  • Do the test given in Para. 3.
       1 If the test gives the maintenance message DEU-B 300RH8:
       2 If the test gives the maintenance message CIDS MID BUS R/ DIR1 (101RH):
     (b) If there is a short circuit:
       1 If there is no short circuit:
       2 If the fault continues:
  • disconnect the electrical connector from the DEU TERMINATION BOX [309RH2] .
  • do a check for a short circuit again.
         a If there is no short circuit:
         b If the fault continues:
  • install the removed DEU-B [300RH8] AMM 23-73-47-400-001,
  • reconnect the electrical connector to the DEU TERMINATION BOX [309RH2] ASM 237306,
  • remove the DEU-B [300RH6] AMM 23-73-47-000-001,
  • do a check for a short circuit again.

  • b.1. If there is no short circuit:
  • install a new DEU-B [300RH6] AMM 23-73-47-400-001,
  • Do the test given in Para. 3.

  • b.2. If the fault continues:
  • disconnect the electrical connector from the DEU CONNECTION BOX [308RH6] ,
  • do a check for a short circuit again.

  • b.2.1. If there is no short circuit:
  • do a check for a short circuit at the disconnected connector between pin 9 and GND (pin 4) and between pin 10 and GND (pin 4).

  • b.2.1.1. If there is a short circuit:
  • repair the wiring between the DEU CONNECTION BOX [308RH6] and the DEU TERMINATION BOX [309RH2] ASM 237306.
  • Do the test given in Para. 3.

  • b.2.1.2. If there is no short circuit:
  • install a new DEU CONNECTION BOX [308RH2] AMM 23-73-42-400-001,
  • Do the test given in Para. 3.

  • b.2.2. If there is a short circuit:
  • install the removed DEU-B [300RH6] AMM 23-73-47-400-001,
  • reconnect the electrical connector to the DEU CONNECTION BOX [308RH6] ,
  • do the steps (4. B. (5) (b) 2 b) again for the subsequent DEU(s) and DEU CONNECTION BOX(es) until the maintenance message stops: ASM 237306
    DEU CONNECTION BOX [308RH2] .
   (6) If the resistance (line to line) is more than 140 ohms (open circuit):
  • disconnect the electrical connector from the DEU TERMINATION BOX [309RH2] ,
  • make sure that the resistance (line to line) is not more than 140 ohms (open circuit) between:
    DEU TERMINATION BOX [309RH2] pin A/1 and pin A/2
     (a) If there is an open circuit:
     (b) If there is no open circuit:
  • reconnect the electrical connector to the DEU TERMINATION BOX [309RH2]
  • disconnect the electrical connector from the DEU CONNECTION BOX [308RH2] .
  • do a check of the wiring (continuity-check) between:
    DIR-CIDS (101RH) connector AA/A14 and the DEU TERMINATION BOX connector pin A/2,
    DIR-CIDS (101RH) connector AA/B14 and the DEU TERMINATION BOX connector pin A/1.
       1 If there is no continuity:
  • repair the wiring between the DIR-CIDS (101RH) and the connector ASM 237306.
  • Do the test given in Para. 3.
       2 If there is continuity:
  • do a check of the wiring (continuity-check) between:
    DEU CONNECTION BOX [308RH2] pin A/1 and pin A/9 ,
    DEU CONNECTION BOX [308RH2] pin A/2 and pin A/10.
         a If there is no continuity:
         b If there is continuity:
  • reconnect the connector to the DEU CONNECTION BOX [308RH2]
  • do the steps 4. B. (6) again for the subsequent DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops:
    DIR-CIDS (101RH) and DEU CONNECTION BOX [308RH6] /connector,
    DIR-CIDS (101RH) and DEU TERMINATION BOX [309RH2] /connector.
   (7) If the resistance (line to line) is less than 80 ohms (short circuit):
     (a) If there is no short circuit:
     (b) If there is a short circuit:
       1 If there is a short circuit:
  • reconnect the electrical connector to the DEU TERMINATION BOX [309RH2]
  • do the steps 4. B. (7) again for the subsequent DEU(s) and DEU CONNECTION BOX(es) until the maintenance message stops: ASM 237306
    DEU-B [300RH6] and DEU CONNECTION BOX [308RH6] ,
    DEU CONNECTION BOX [308RH2] ,
       2 If there is no short circuit:
  • do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306
         a If there is a short circuit:
  • repair the wiring between the related DEU CONNECTION BOX 308RHxx and the DEU CONNECTION/ TERMINATION BOX 308RHxx/309RHxx ASM 237306.
  • Do the test given in Para. 3.
         b If there is no short circuit:
Subtask 23-73-00-810-142-Q ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message CIDS MID BUS R/DIR1 (101RH):
  • make sure that at least one cabin door is open.
  • on the overhead panel 25VU:
    make sure that the EMER EXIT LT switch (4WL) is in the OFF position.
  • remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001,
  • close these CBs:
    49VU: 157RH COM/CIDS/ DIR ESS/ 2,
    49VU: 18WH AIR COND/ CIDS/SDF/ DIR 2 ESS,
    120VU: 156RH COM NAV/ CIDS/ DIR NORM/ 2,
    122VU: 14WH AIR COND/ CIDS/ SDF/ DIR NORM/ 2.
  • wait for approx. 120s,
  • do the CIDS2 Interface and Power-Up Test via the CFDS/MCDU AMM 23-73-00-740-005.
   (1) If the test is OK:
   (2) If the fault continues:
  • remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
  • during the installation of the DIR-CIDS, 1 [101RH] do not close these CBs:
    49VU: 157RH COM/CIDS/ DIR ESS/ 2,
    49VU: 18WH AIR COND/ CIDS/SDF/ DIR 2 ESS,
    120VU: 156RH COM NAV/ CIDS/ DIR NORM/ 2,
    122VU: 14WH AIR COND/ CIDS/ SDF/ DIR NORM/ 2.
  • install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
  • Do the test given in Para. 3.
   (3) If the test is OK:
   (4) If the fault continues:
  • remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001.
  • open these CBs:
    49VU: 153RH COM/CIDS/DEU B/ESS,
    120VU: 193RH COM NAV/CIDS/DEU B/NORM FWD,
    2001VU: 194RH COM NAV/CIDS/DEU B/NORM AFT.
  • make sure that the resistance (line to line) at DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] connector AA/A14 and connector AA/B14 is between approx. 80 and 140 ohm ASM 237306.
   (5) If the resistance (line to line) is between approx. 80 and 140 ohm:
  • make sure that the resistance (line to GND) is not less than 7k ohm (short circuit) between:
    DIR-CIDS (101RH) and (102RH) connector AA/A14 and GND,
    DIR-CIDS (101RH) and (102RH) connector AA/B14 and GND. ASM 237306
     (a) If there is no short circuit:
  • remove the DEU-B [300RH6] AMM 23-73-47-000-001,
  • install the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
  • close these CBs:
    49VU: 153RH COM/CIDS/DEU B/ESS,
    120VU: 193RH COM NAV/CIDS/DEU B/NORM FWD,
    2001VU: 194RH COM NAV/CIDS/DEU B/NORM AFT.
  • Do the test given in Para. 3.
       1 If the test gives the maintenance message DEU-B [300RH8] :
       2 If the test gives the maintenance message CIDS MID BUS R/DIR1 (101RH):
     (b) If there is a short circuit:
       1 If there is no short circuit:
       2 If the fault continues:
  • disconnect the electrical connector from the DEU TERMINATION BOX [309RH2] ,
  • do a check for a short circuit again.
         a If there is no short circuit:
         b If the fault continues:
  • install the removed DEU-B [300RH8] AMM 23-73-47-400-001,
  • reconnect the electrical connector to the DEU TERMINATION BOX [309RH2] ASM 237306,
  • remove the DEU-B [300RH6] AMM 23-73-47-000-001,
  • do a check for a short circuit again.

  • b.1. If there is no short circuit:
  • install a new DEU-B [300RH6] AMM 23-73-47-400-001.
  • Do the test given in Para. 3.

  • b.2. If the fault continues:
  • disconnect the electrical connector from the DEU CONNECTION BOX [308RH6] ,
  • do a check for a short circuit again.

  • b.2.1. If there is no short circuit:
  • do a check for a short circuit at the disconnected connector between pin 9 and GND (pin 4) and between pin 10 and GND (pin 4).

  • b.2.1.1. If there is a short circuit:
  • repair the wiring between the DEU CONNECTION BOX [308RH6] and the DEU TERMINATION BOX [309RH2] ASM 237306.
  • Do the test given in Para. 3.

  • b.2.1.2. If there is no short circuit:
  • install a new DEU CONNECTION BOX [308RH2] AMM 23-73-42-400-001.
  • Do the test given in Para. 3.

  • b.2.2. If there is a short circuit:
  • install the removed DEU-B [300RH6] AMM 23-73-47-400-001,
  • reconnect the electrical connector to the DEU CONNECTION BOX [308RH6] ,
  • do the steps (4. B. (5) (b) 2 b) again for the subsequent DEU(s) and DEU CONNECTION BOX(es) until the maintenance message stops: ASM 237306
    DEU-B [300RH4] and DEU CONNECTION BOX [308RH4] ,
    DEU CONNECTION BOX [308RH2] .
   (6) If the resistance (line to line) is more than 140 ohm (open circuit):
  • disconnect the electrical connector from the DEU TERMINATION BOX [309RH2] ,
  • make sure that the resistance (line to line) is not more than 140 ohm (open circuit) between:
    DEU TERMINATION BOX [309RH2] pin A/1 and pin A/2.
     (a) If there is an open circuit:
     (b) If there is no open circuit:
  • reconnect the electrical connector to the DEU TERMINATION BOX [309RH2] ,
  • disconnect the electrical connector from the DEU CONNECTION BOX [308RH2] ,
  • do a check of the wiring (continuity-check) between:
    DIR-CIDS (101RH) connector AA/A14 and the DEU TERMINATION BOX connector pin A/2,
    DIR-CIDS (101RH) connector AA/B14 and the DEU TERMINATION BOX connector pin A/1.
       1 If there is no continuity:
  • repair the wiring between the DIR-CIDS (101RH) and the connector ASM 237306.
  • Do the test given in Para. 3.
       2 If there is continuity:
  • do a check of the wiring (continuity-check) between:
    DEU CONNECTION BOX [308RH2] pin A/1 and pin A/9 ,
    DEU CONNECTION BOX [308RH2] pin A/2 and pin A/10.
         a If there is no continuity:
         b If there is continuity:
  • reconnect the connector to the DEU CONNECTION BOX [308RH2] ,
  • do the steps 4. B. (6) again for the subsequent DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops:
    DIR-CIDS (101RH) and DEU CONNECTION BOX [308RH6] /connector,
    DIR-CIDS (101RH) and DEU CONNECTION BOX [308RH4] /connector,
    DIR-CIDS (101RH) and DEU TERMINATION BOX [309RH2] /connector.
   (7) If the resistance (line to line) is less than 80 ohm (short circuit):
     (a) If there is no short circuit:
     (b) If there is a short circuit:
       1 If there is a short circuit:
  • reconnect the electrical connector to the DEU TERMINATION BOX [309RH2] ,
  • do the steps 4. B. (7) again for the subsequent DEU(s) and DEU CONNECTION BOX(es) until the maintenance message stops: ASM 237306
    DEU-B [300RH6] and DEU CONNECTION BOX [308RH6] ,
    DEU-B [300RH4] and DEU CONNECTION BOX [308RH4] ,
    DEU CONNECTION BOX [308RH2] .
       2 If there is no short circuit:
  • do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306.
         a If there is a short circuit:
  • repair the wiring between the related DEU CONNECTION BOX 308RHxx and the DEU CONNECTION/ TERMINATION BOX 308RHxx/309RHxx ASM 237306.
  • Do the test given in Para. 3.
         b If there is no short circuit:
Subtask 23-73-00-810-143-A ** ON A/C NOT FOR ALL
C. Installation of removed components
Subtask 23-73-00-810-143-B ** ON A/C NOT FOR ALL
C. Installation of removed components
  • Install the removed DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
  • Install all the removed DEU-B (300RHxx) AMM 23-73-47-400-001.
  • Reconnect all the DEU CONNECTION/ TERMINATION BOX-connectors to the related DEU CONNECTION/ TERMINATION BOX (308RHxx/309RHxx) ((Ref. AMM 23-73-42/43-400-00100)).
Subtask 23-73-00-710-259-A
D. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:38:59 UTC