W DOC AIRBUS | TSM A320F

AAP - No control of the CIDS cabin systems


TASK 23-73-00-810-868-A
AAP - No control of the CIDS cabin systems


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 23-73-00-810-878-A
AAP - Fault in the AAP
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237310
AMM 23-73-13-000-001
Removal of the Aft/Additional Attendant Panel
AMM 23-73-13-400-001
Installation of the Aft/Additional Attendant Panel
AMM 23-73-47-000-001
Removal of the Decoder/Encoder Unit B (300RH)
AMM 23-73-47-400-001
Installation of the Decoder/Encoder Unit B (300RH)
3. Fault Confirmation
Subtask 23-73-00-710-174-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS BITE test through the CFDS.
   (2) Use the AAP to control some system controlled through the AAP.
Subtask 23-73-00-710-174-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up Test through the CFDS AMM 23-73-00-740-005.
   (2) Use the AAP to control some systems controlled through the AAP.
4. Fault Isolation
Subtask 23-73-00-810-409-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-410-A ** ON A/C NOT FOR ALL
B. If the CFDS gives the maintenance message ATTND PNL AFT (126RH):
Subtask 23-73-00-810-411-A ** ON A/C NOT FOR ALL
C. If the CFDS gives no ATTND PNL AFT fault message and you cannot control the AAP controlled system through the AAP:
   (1) If the fault continues:
   (2) If the fault continues:
  • check and repair if necessary the wiring between the:
    DEU-B 300RH5 conn. C/11 and AAP 126RH conn. A/11,
    DEU-B 300RH5 conn. C/9 and AAP 126RH conn. A/24,
    DEU-B 300RH5 conn. C/13 and AAP 126RH conn. A/10,
    DEU-B 300RH5 conn. C/45 and AAP 126RH conn. A/9,
    ASM 237310.
Subtask 23-73-00-810-410-B ** ON A/C NOT FOR ALL
D. If the CFDS gives the maintenance message AAP(126RH) <NAME>:
Subtask 23-73-00-810-411-B ** ON A/C NOT FOR ALL
E. If the CFDS gives no AAP (126RH) <NAME> fault message and you cannot control the AAP controlled system through the AAP:
   (1) If the fault continues:
Subtask 23-73-00-710-222-A
F. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:54 UTC