W DOC AIRBUS | TSM A320F

AAP - Fault in the AAP


TASK 23-73-00-810-878-A
AAP - Fault in the AAP


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237310
AMM 23-73-13-000-001
Removal of the Aft/Additional Attendant Panel
AMM 23-73-13-400-001
Installation of the Aft/Additional Attendant Panel
ASM 237327
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 23-73-47-000-001
Removal of the Decoder/Encoder Unit B (300RH)
AMM 23-73-47-400-001
Installation of the Decoder/Encoder Unit B (300RH)
3. Fault Confirmation
Subtask 23-73-00-710-225-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS BITE test through the CFDS.
AMM 23-73-00-740-005
Subtask 23-73-00-710-225-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up test through the CFDS.
AMM 23-73-00-740-005
4. Fault Isolation
Subtask 23-73-00-810-488-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-489-D ** ON A/C NOT FOR ALL
B. If the CIDS1 BITE test gives the maintenance message ATTND PNL AFT:
  • make sure that at least one cabin door is open,
  • make sure that the EMER LT (4WL) switch is in the OFF position,
  • open these CBs:
    49VU: 150RH (G01) COM DIR ESS/1
    49VU: 157RH (G02) COM DIR ESS/2
    121VU:151RH (M06) CIDS/DIR NORM/1
    121VU:156RH (M07) CIDS/DIR NORM/2,
  • wait for approx. 10 s and close the CBs 156RH and 157RH.
  • stop for approx. 120 s,
  • do the CIDS2 BITE test.
   (1) If the CIDS2 BITE test does not give the message ATTND PNL AFT:
     (a) If the fault continues:
       1 If the fault continues:
         a If the fault continues:
  • do a check and repair the wiring between the:
    DEU-B (300RH5) connector C/30 and AAP (126RH) connector A/1,
    DEU-B (300RH5) connector C/31 and AAP (126RH) connector A/2,
    DEU-B (300RH5) connector C/14 and AAP (126RH) connector A/4,
    DEU-B (300RH5) connector C/15 and AAP (126RH) connector A/5,
    DEU-B (300RH5) connector C/10 and AAP (126RH) connector A/7,
    DEU-B (300RH5) connector C/8 and AAP (126RH) connector A/8,
    AAP (126RH) connector C/6 and GND ASM 237310.
Subtask 23-73-00-810-489-F ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring between:
    DEU-B connector C/40 and AAP connector A/1,
    DEU-B connector C/41 and AAP connector A/2,
    DEU-B connector C/24 and AAP connector A/4,
    DEU-B connector C/39 and AAP connector A/7,
    DEU-B connector C/23 and AAP connector A/8,
    AAP connector A/3 and GND.
    ASM 237327
Subtask 23-73-00-810-490-A ** ON A/C NOT FOR ALL
C. Install the removed DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
Subtask 23-73-00-710-226-A
D. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:38:59 UTC