PTP - Fault on the Programming and Test Panel
TASK 23-73-00-810-867-A
PTP - Fault on the Programming and Test Panel
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-172-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-404-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:53 UTC
PTP - Fault on the Programming and Test Panel
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 23-73-00-810-856-A | PTP - Fault in the Programming and Test Panel |
| AMM 23-73-18-000-001 | Removal of the Programming and Test Panel |
| AMM 23-73-18-400-001 | Installation of the Programming and Test Panel |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-172-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the PTP test through the CFDS.
(2) Use the PTP to control some system statuses, tests and programming.
4. Fault Isolation(1) Do the PTP test through the CFDS.
(2) Use the PTP to control some system statuses, tests and programming.
Subtask 23-73-00-810-404-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-405-A ** ON A/C NOT FOR ALL B. If the CFDS gives the maintenance message P & T PNL 110RH:
Subtask 23-73-00-810-406-A ** ON A/C NOT FOR ALL - do the trouble shooting for the CFDS maintenance message P & T PNL 110RH (Ref. TSM TASK 23-73-00-810-856).
C. If the CFDS gives no P & T PNL fault message and you cannot control the PTP controlled system tests through the PTP:
Subtask 23-73-00-710-221-A ** ON A/C NOT FOR ALL - replace the PROGRAMMING AND TEST PANEL [110RH] AMM 23-73-18-000-001 and AMM 23-73-18-400-001.
- replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
D. Do the test given in Para. 3.A.