PTP - Fault in the Programming and Test Panel


TASK 23-73-00-810-856-A
PTP - Fault in the Programming and Test Panel


1. Possible Causes
  • PROGRAMMING AND TEST PANEL [110RH]
  • DIR-CIDS, 1 [101RH]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 237309
AMM 23-73-18-000-001
Removal of the Programming and Test Panel
AMM 23-73-18-400-001
Installation of the Programming and Test Panel
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-73-00-710-067-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the PTP test through the CFDS.
4. Fault Isolation
Subtask 23-73-00-810-150-A ** ON A/C NOT FOR ALL
A. If the CFDS gives the maintenance message P&T PNL:
Subtask 23-73-00-810-152-D ** ON A/C NOT FOR ALL
B. If the fault continues:
  • make sure that at least one cabin door is open,
  • make sure that the EMER LT (4WL) switch is in the OFF position,
  • open these CBs:
    49VU: 150RH (G01) COM DIR ESS/1
    49VU: 157RH (G02) COM DIR ESS/2
    121VU:151RH (M06) CIDS/DIR NORM/1
    121VU:156RH (M07) CIDS/DIR NORM/2,
  • wait for approx. 10 s and close the CBs 156RH and 157RH.
  • stop for approx. 120 s,
  • do the PTP test again.
   (1) If the test is OK:
Subtask 23-73-00-810-153-A ** ON A/C NOT FOR ALL
C. If the fault continues:
  • do a check and repair the wiring between:
    CB 161RH and the PTP (115RH) connector A/17,
    DIR-CIDS (101RH) connector AA/F12 and PTP (115RH) connector A/1,
    DIR-CIDS (101RH) connector AA/G12 and PTP (115RH) connector A/2,
    DIR-CIDS (101RH) connector AA/J12 and PTP (115RH) connector A/4,
    DIR-CIDS (101RH) connector AA/K12 and PTP (115RH) connector A/5,
    DIR-CIDS (102RH) connector AA/F12 and PTP (115RH) connector A/1,
    DIR-CIDS (102RH) connector AA/G12 and PTP (115RH) connector A/2,
    DIR-CIDS (102RH) connector AA/J12 and PTP (115RH) connector A/4,
    DIR-CIDS (102RH) connector AA/K12 and PTP (115RH) connector A/5,
    PTP (115RH) connector A/3 and GND,
    PTP (115RH) connector A/8 and GND,
    PTP (115RH) connector A/16 and GND ASM 237309.
Subtask 23-73-00-810-154-A ** ON A/C NOT FOR ALL
D. Install the removed DIR-CIDS (101RH) AMM 23-73-34-400-001.
Subtask 23-73-00-810-155-A ** ON A/C NOT FOR ALL
E. Do the test given in Para. 3.A.