73-11 (PW11) - FUEL DISTRIBUTION SYSTEM
- PB.201 CONF:[21] FUEL DISTRIBUTION SYSTEM - FAULT ISOLATION PROCEDURES
-
73-11-00-810-801-A
[PW11]
[8]
FMV Nullshift Bias Channel A -
73-11-00-810-802-A
[PW11]
[8]
FMV Nullshift Bias Channel B -
73-11-00-810-803-A
[PW11]
[8]
Integrated Fuel Pump and Control/FMV-LVDT Electrical Failure Channel A -
73-11-00-810-804-A
[PW11]
[8]
Integrated Fuel Pump and Control/FMV-LVDT Electrical Failure Channel B -
73-11-00-810-805-A
[PW11]
[8]
Integrated Fuel Pump and Control/FMV-TM Electrical Failure Channel A -
73-11-00-810-806-A
[PW11]
[8]
Integrated Fuel Pump and Control/FMV-TM Electrical Failure Channel B -
73-11-00-810-807-A
[PW11]
[8]
Integrated Fuel Pump and Control/Protection TM Electrical Failure Channel A -
73-11-00-810-808-A
[PW11]
[8]
Integrated Fuel Pump and Control/FMV-Track Check Channel A -
73-11-00-810-809-A
[PW11]
[8]
Integrated Fuel Pump and Control/HPSOV Proximity Switch Erroneously Reading HPSOV Closed -
73-11-00-810-810-A
[PW11]
[8]
Integrated Fuel Pump and Control/HPSOV Proximity Switch Erroneously Reading HPSOV Open -
73-11-00-810-812-A
[PW11]
[8]
Fuel Filter Blockage and Bypass event -
73-11-00-810-813-A
[PW11]
[8]
Integrated Fuel Pump and Control/FMV-Track Check Channel B -
73-11-00-810-814-A
[PW11]
[8]
Master Lever Hardwired Discrete Signal Failure Channel B -
73-11-00-810-815-A
[PW11]
[8]
Master Lever Hardwired Discrete Disagreement Failure -
73-11-00-810-816-A
[PW11]
[8]
HPSOV Position Feedback Signal Failure Channel A -
73-11-00-810-817-A
[PW11]
[8]
HPSOV Position Feedback Signal Failure Channel B -
73-11-00-810-818-A
[PW11]
[8]
HPSOV Position Disagreement Failure -
73-11-00-810-819-A
[PW11]
[8]
HPSOV Mechanically Stuck -
73-11-00-810-822-A
[PW11]
[8]
Fuel Filter Assembly Blocage of Filter Element -
73-11-00-810-823-A
[PW11]
[8]
FMV LVDT disagreement Failure -
73-11-00-810-824-A
[PW11]
[8]
Master Lever Position Discrete Disagrees with EIU Data -
73-11-00-810-825-A
[PW11]
[8]
Integrated Fuel Pump and Control/Protection TM Electrical Failure Channel B -
73-11-00-810-826-A
[PW11]
[8]
Fuel Filter Efficiency Degraded -
73-11-00-810-827-A
[PW11]
[8]
TCM Cutback Test Failed -
73-11-00-810-828-A
[PW11]
[8]
TCM Enable Discrete Signal Failure (Single) Channel A -
73-11-00-810-829-A
[PW11]
[8]
TCM Enable Discrete Signal Failure (Single) Channel B -
73-11-00-810-830-A
[PW11]
[8]
Master Lever Hardwired Discrete Signal Failure Channel A -
73-11-00-810-841-A
[PW11]
[8]
TCM Cutback Accommodation Activated in Flare only -
73-11-00-810-842-A
[PW11]
[8]
TCM Cutback Accommodation Activated -
73-11-00-810-843-A
[PW11]
[8]
TCM Cutback Accommodation Activated in Flare or Take Off Phase (Control System Fault Alert) -
73-11-00-810-844-A
[PW11]
[8]
Flow Divider Valve Mechanically Stuck -
73-11-00-810-845-A
[PW11]
[8]
Fuel Flow not at Shutoff During Start - Failure on Both Channels -
73-11-00-810-847-A
[PW11]
[8]
Active Bypass Directional Control Valve Solenoid Electrical Failure Channel A -
73-11-00-810-848-A
[PW11]
[8]
Active Bypass Directional Control Valve Solenoid Electrical Failure Channel B -
73-11-00-810-849-A
[PW11]
[8]
Bypass Direction Control Valve Stuck -
73-11-00-810-871-A
[PW11]
[8]
Master Lever Hardwired Discrete Signal Failure on Channel A and B -
73-11-00-810-872-A
[PW11]
[8]
TCM Enable Discrete Signal Failure (Single) on Channel A and B -
73-11-00-810-873-A
[PW11]
[8]
Active Bypass Directional Control Valve Solenoid Electrical Failure on Channel A and B -
73-11-00-810-876-A
[PW11]
[8]
Integrated Fuel Pump and Control/FMV-LVDT Electrical Failure Channel A and B -
73-11-00-810-877-A
[PW11]
[8]
HPSOV Position Feedback Signal Failure Channel A and B -
73-11-00-810-878-A
[PW11]
[8]
Integrated Fuel Pump and Control/FMV-TM Electrical Failure Channel A and B -
73-11-00-810-879-A
[PW11]
[8]
Integrated Fuel Pump and Control/FMV-Track Check Channel A and B -
73-11-00-810-880-A
[PW11]
[8]
BDCV Test Abort Count on Both Channels
-
73-11-00-810-801-A
[PW11]
[8]
- PB.201 CONF:[21] FUEL FLOW DIVIDER - FAULT ISOLATION PROCEDURES
-
73-11-03-810-801-A
[PW11]
[8]
Flow Divider Valve Solenoid Electrical Failure Channel A -
73-11-03-810-802-A
[PW11]
[8]
Flow Divider Valve Solenoid Electrical Failure Channel B -
73-11-03-810-803-A
[PW11]
[8]
Flow Divider Valve Solenoid Electrical Failure on Channel A and B
-
73-11-03-810-801-A
[PW11]
[8]