W DOC AIRBUS | TSM A320F

Master Lever Hardwired Discrete Signal Failure on Channel A and B


TASK 73-11-00-810-871-A
Master Lever Hardwired Discrete Signal Failure on Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 73-11-00-810-814-A
Master Lever Hardwired Discrete Signal Failure Channel B
TSM TASK 73-11-00-810-830-A
Master Lever Hardwired Discrete Signal Failure Channel A
3. Fault Confirmation
Subtask 73-11-00-710-132-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 73-11-00-810-161-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-830).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-814).
5. Close-up
Subtask 73-11-00-860-111-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:36:36 UTC