Master Lever Hardwired Discrete Signal Failure on Channel A and B
TASK 73-11-00-810-871-A
Master Lever Hardwired Discrete Signal Failure on Channel A and B
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 73-11-00-710-132-A ** ON A/C NOT FOR ALL
Subtask 73-11-00-810-161-A ** ON A/C NOT FOR ALL
Subtask 73-11-00-860-111-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:36:36 UTC
Master Lever Hardwired Discrete Signal Failure on Channel A and B
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 73-11-00-810-814-A | Master Lever Hardwired Discrete Signal Failure Channel B |
| TSM TASK 73-11-00-810-830-A | Master Lever Hardwired Discrete Signal Failure Channel A |
Subtask 73-11-00-710-132-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault IsolationSubtask 73-11-00-810-161-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
(1) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-830).
(2) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-814).
5. Close-up(1) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-830).
(2) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-814).
Subtask 73-11-00-860-111-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(1) Make sure that the work area is clean and clear of tools and other items.