W DOC AIRBUS | AMM A320F

Installation of the Upper Starter Duct [CFMI]


TASK 80-13-43-400-040-A
Installation of the Upper Starter Duct


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 70 and 50 lbf.in (0.79 and 0.57 m.daN ) T
No specific
Torque wrench: range to between 80 and 70 lbf.in (0.90 and 0.79 m.daN ) T
No specific
Torque wrench: range to between 900 and 810 lbf.in (10.17 and 9.15 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.CP8002)
lockwire 0.032 in. (0.8 mm) dia
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 80-13-43-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
WARNING: IF IT IS NECESSARY TO ENERGIZE THE AIRCRAFT FOR A MAINTENANCE WORK WHILE YOU DO THIS MAINTENANCE PROCEDURE, MAKE SURE THAT ONLY EXTERNAL POWER IS USED. THE USE OF APU OR ENGINE POWER CAN CAUSE PRESSURIZED AIR LEAKAGE IN THE PNEUMATIC SYSTEM, AND INJURY CAN OCCUR.
   (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
   (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
   (3) On the AIR COND panel 30VU:
  • make sure that the APU BLEED pushbutton switch is released (ON legend is off),
  • make sure that a WARNING NOTICE(S) is in position to tell persons not to operate the pneumatic system.
   (4) On the HP ground connector:
  • make sure that a WARNING NOTICE(S) is in position to tell persons not to pressurize the pneumatic system.
Subtask 80-13-43-010-053-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Make sure that the fan cowl doors are open: (Ref. AMM TASK 71-13-00-010-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
4. Procedure
Subtask 80-13-43-420-051-A ** ON A/C NOT FOR ALL
A. Install the Upper Starter Duct.
   (1) Remove the protective covers from the ducts.
CAUTION: MAKE SURE THAT THE V-CLAMP ATTACHMENTS CAN NOT TOUCH ENGINE COMPONENTS OR STRUCTURE, TO PREVENT DAMAGE.
     (a) Attach the upper starter the duct (10) to the starter valve and to the pylon duct with the couplings (30). Tighten the couplings sufficiently to attach the duct (10) to the starter valve and to the pylon duct.
Subtask 80-13-43-420-052-B ** ON A/C NOT FOR ALL 5. Close-up
Subtask 80-13-43-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors: (
Ref. AMM TASK 71-13-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:44:14 UTC