Inspection of the scavenge screen plugs [CFML]
TASK 79-35-00-040-807-A
Inspection of the scavenge screen plugs
1. Reason for the Job
MMEL 79-09-02E
ENG 1(2) OIL FILTER CLOG ALERT
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 79-35-00-860-060-A
Subtask 79-35-00-200-052-A
Subtask 79-35-00-860-061-A
[Rev.10 from 2021]
2026.04.01 03:43:39 UTC
Inspection of the scavenge screen plugs
1. Reason for the Job
MMEL 79-09-02E
ENG 1(2) OIL FILTER CLOG ALERT
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 79-00-00-200-806-A | Visual Inspection of the A, B and C Sumps, the Accessory Gearbox (AGB) and the Transfer Gearbox Sump Scavenge Screen Plugs for Debris |
Subtask 79-35-00-860-060-A
A. Not applicable
4. ProcedureSubtask 79-35-00-200-052-A
A. Do the inspection of the scavenge screen plugs (Ref. AMM TASK 79-00-00-200-806).
(1) Check that there is no presence of chips.
5. Close-up(1) Check that there is no presence of chips.
Subtask 79-35-00-860-061-A
A. Aircraft Maintenance Configuration
(1) Make an entry in the logbook to record that the scavenge screen plugs have been inspected.
(1) Make an entry in the logbook to record that the scavenge screen plugs have been inspected.