Check for no fault of the Oil Debris Monitoring System [CFML]
TASK 79-35-00-040-806-A
Check for no fault of the Oil Debris Monitoring System
1. Reason for the Job
MMEL 79-09-02F
ENG 1(2) OIL FILTER CLOG ALERT
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 79-35-00-860-058-A
Subtask 79-35-00-710-052-A
Subtask 79-35-00-860-059-A
[Rev.10 from 2021]
2026.04.01 03:43:37 UTC
Check for no fault of the Oil Debris Monitoring System
1. Reason for the Job
MMEL 79-09-02F
ENG 1(2) OIL FILTER CLOG ALERT
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 73-29-00-710-802-A | FADEC Test (Menu Mode) |
Subtask 79-35-00-860-058-A
A. Not applicable
4. ProcedureSubtask 79-35-00-710-052-A
A. Check of the oil debris systems
(1) Do the a FADEC TEST (Ref. AMM TASK 73-29-00-710-802)
(a) Verify that the message "ENGXB ODMS SENSOR MONITOR" is not displayed.
5. Close-up(1) Do the a FADEC TEST (Ref. AMM TASK 73-29-00-710-802)
(a) Verify that the message "ENGXB ODMS SENSOR MONITOR" is not displayed.
Subtask 79-35-00-860-059-A
A. Aircraft Maintenance Configuration
(1) Make an entry in the logbook to record that the Oil Debris Monitoring System operationally tested.
(1) Make an entry in the logbook to record that the Oil Debris Monitoring System operationally tested.