W DOC AIRBUS | AMM A320F

Removal of the Thrust Reverser Opening Actuator [IAE]


TASK 78-36-51-000-010-A
Removal of the Thrust Reverser Opening Actuator


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: DO NOT LET ENGINE OIL STAY ON YOUR SKIN FOR A LONG TIME. FLUSH THE OIL FROM YOUR SKIN WITH WATER. THE OIL IS POISONOUS AND CAN GO THROUGH YOUR SKIN AND INTO YOUR BODY.
CAUTION: DO NOT LET ENGINE FUEL OR OIL FALL ON THE ENGINE. UNWANTED FUEL OR OIL MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FUEL OR OIL CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
ZONE: 400
FIN: 3003KM1 ** ON A/C NOT FOR ALL
FIN: 3003KM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CONTAINER 5 L (1.32 USGAL)
No specific
AR
COVER - BLANKING
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
3. Job Set-up
Subtask 78-36-51-941-053-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-36-51-010-055-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010).
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Put the ACCESS PLATFORM 2M (6 FT) in to position.
Subtask 78-36-51-040-053-A ** ON A/C NOT FOR ALL
C. Deactivate the thrust reverser.
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Deactivate the thrust reverser hydraulic control unit (HCU) (Ref. AMM TASK 78-30-00-040-012).
Subtask 78-36-51-010-056-A ** ON A/C NOT FOR ALL
D. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
4. Procedure
Subtask 78-36-51-020-052-A ** ON A/C NOT FOR ALL
A. Disconnect the hydraulic hose from the opening actuator.
   (1) Remove the nut (9), the screw (6), the washer (8) and the clamp (7) that attach the flexible hose cover (11) to the opening actuator (5).
   (2) Open the end cover to get access to the hose nut (10).
   (3) Put a CONTAINER 5 L (1.32 USGAL) under the hose connection.
   (4) Disconnect the hydraulic hose (12) from the opening actuator.
   (5) Remove the container and discard the drained oil.
Subtask 78-36-51-620-051-A ** ON A/C NOT FOR ALL
B. Put the applicable COVER - BLANKING on all of the openings.
Subtask 78-36-51-020-051-A ** ON A/C NOT FOR ALL
C. Remove the opening actuator.
   (1) Remove the nut (2), the bolt (4), the washer (18), the washer (19) and the bushing (3) that attach the actuator (5) to the mount (15).
   (2) Remove the nut (17), the bolt (13), the washer (14), the washer (20) and the bushing (16) that attach the opening actuator to the pylon hinge beam (1).
   (3) Remove the opening actuator.
[Rev.10 from 2021] 2026.04.01 13:12:41 UTC