Removal of the Thrust Reverser Hold Open Rods (HOR) [PW11]
TASK 78-36-04-000-801-A
Removal of the Thrust Reverser Hold Open Rods (HOR)
This procedure is the same for the left and right thrust reverser cowl door hold open rods.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-36-04-941-050-A ** ON A/C NOT FOR ALL
Subtask 78-36-04-020-050-A ** ON A/C NOT FOR ALL
(2) Remove the four bolts (2) and four washers (3) that attach the HOR (1) to the torque box bracket.
(3) Remove the applicable HOR (1) from the thrust reverser half.
(4) Installation of protection covers
[Rev.10 from 2021]
2026.04.01 03:34:07 UTC
Removal of the Thrust Reverser Hold Open Rods (HOR)
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
1. Reason for the JobThis procedure is the same for the left and right thrust reverser cowl door hold open rods.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | COVER - PROTECTION |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
Subtask 78-36-04-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 78-36-04-010-050-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 78-36-04-040-050-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
C. Deactivation of the Thrust Reverser for Maintenance
4. ProcedureWARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805). Subtask 78-36-04-020-050-A ** ON A/C NOT FOR ALL
CAUTION:
WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
A. Remove the Thrust Reverser Hold Open Rod (HOR) NOTE: There is one HOR on each thrust reverser half. This removal procedure is the same for each HOR.
(1) Release the end of the applicable HOR (1) from the HOR stow bracket on the thrust reverser torque box. (2) Remove the four bolts (2) and four washers (3) that attach the HOR (1) to the torque box bracket.
(3) Remove the applicable HOR (1) from the thrust reverser half.
(4) Installation of protection covers
CAUTION:
INSTALL PROTECTION COVERS ON ALL THE OPENINGS IMMEDIATELY TO PREVENT DAMAGE TO THE ENGINE.
(a) Make sure that you install COVER - PROTECTION as necessary to prevent damage to the engine.
Thrust Reverser Hold Open Rods (HOR)