W DOC AIRBUS | AMM A320F

Installation of the Blocker Door Deploy Switch [CFMI]


TASK 78-31-17-400-040-A
Installation of the Blocker Door Deploy Switch


ZONE: 400
FIN: 4103KS1 ** ON A/C NOT FOR ALL
FIN: 4103KS2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
PLIERS - NOSE, SOFT, LONG
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 45 and 35 lbf.in (0.51 and 0.40 m.daN ) T
No specific
Torque wrench: range to between 80 and 70 lbf.in (0.90 and 0.79 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.CP2245)
finish paint EA4 blue 5991
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-31-00-710-040-A-01
Operational Test of the Thrust Reverser without CFDS - Engine not Running
TASK 78-31-00-710-040-A-02
Operational Test of the Thrust Reverser without CFDS - Engine Running
TASK 78-31-00-710-040-A
Operational Test of the Thrust Reverser System
TASK 78-31-00-710-040-A-01
Operational Test of the Thrust Reverser without CFDS - Engine not Running
TASK 78-31-00-710-040-A-02
Operational Test of the Thrust Reverser without CFDS - Engine Running
3. Job Set-up
Subtask 78-31-17-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
   (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
   (3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 78-31-17-010-070-A ** ON A/C NOT FOR ALL
B. Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 78-31-17-040-061-A ** ON A/C NOT FOR ALL
C. Make sure that the thrust reverser is unserviceable (Ref. AMM TASK 78-30-00-481-041).
4. Procedure
Subtask 78-31-17-420-053-A ** ON A/C NOT FOR ALL
A. Installation of the Blocker Door Deploy Switch
NOTE: You should apply a witness line of finish paint EA4 blue 5991 (Material No.CP2245) on all nuts and connections when you have checked their torques.
   (1) Install the blocker door deploy switch.
   (2) Connect the beam electrical harness on the deploy switch.
   (3) Tighten the coupling nuts of the deploy switch connectors with PLIERS - NOSE, SOFT, LONG.
   (4) Install the four bolts.
   (5) TORQUE the bolts to between 80 and 70 lbf.in (0.90 and 0.79 m.daN ) T.
   (6) Install the deploy switch access door.
   (7) Install the three screws.
   (8) TORQUE the screws to between 45 and 35 lbf.in (0.51 and 0.40 m.daN )
T.
5. Close-up
Subtask 78-31-17-440-054-A ** ON A/C NOT FOR ALL
Subtask 78-31-17-410-057-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the access platform(s).
Subtask 78-31-17-710-053-A ** ON A/C NOT FOR ALL
C. Do an operational test of the thrust reverser system from the CFDS (Ref. AMM TASK 78-31-00-710-040).
NOTE: As an alternative procedure, you can do this operational test without the CFDS:
[Rev.10 from 2021] 2026.04.01 13:10:58 UTC