W DOC AIRBUS | AMM A320F

Deactivation of the Thrust Reverser System after Flight and ECAM warning REV INHIBITED [PW11]


TASK 78-30-00-040-812-A
Deactivation of the Thrust Reverser System after Flight and ECAM warning REV INHIBITED


1. Reason for the Job
MMEL 78-30-01A
THRUST REVERSER
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 78-30-00-040-806-A
Deactivation of the Thrust Reverser for Flight
3. Job Set-up
Subtask 78-30-00-860-073-A ** ON A/C NOT FOR ALL
A. Not applicable
4. Procedure
Subtask 78-30-00-040-079-A ** ON A/C NOT FOR ALL
A. Deactivate the Trhust Reverser for Flight (Ref. AMM TASK 78-30-00-040-806)
Subtask 78-30-00-710-068-A ** ON A/C NOT FOR ALL
B. Do an operational test of the thrust reverser with the MCDU.
   (1) Check for the warning of the thrust reverser inhibition on the upper ECAM display unit.
     (a) On the ENG section of the maintenance panel 50VU:
  • Release the FADEC GND PWR/1(2) pushbutton switch (the ON legend comes on).
     (b) On the upper ECAM display unit:
  • Make sure that the REV INHIBITED warning comes into view and the ENG1(2) REVERSE UNLOCKED and ENG1(2) REV PRESSURIZED warnings do not come into view.
5. Close-up
Subtask 78-30-00-860-074-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make an entry in the logbook to record that the Thrust Reverser has been deactivated.
[Rev.10 from 2021] 2026.04.01 03:30:40 UTC