Remove Variable Stator Vane Actuator (VSVA) for Shop Maintenance (Cleaning) [IAE]
TASK 75-32-41-920-802-A
Remove Variable Stator Vane Actuator (VSVA) for Shop Maintenance (Cleaning)
1. Reason for the Job
Refer to the MPD TASK: 753241-I1
REMOVE VARIABLE STATOR VANE ACTUATOR (VSVA) FOR SHOP MAINTENANCE (CLEANING)
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 75-32-41-010-072-A ** ON A/C NOT FOR ALL
Subtask 75-32-41-920-050-A ** ON A/C NOT FOR ALL
Subtask 75-32-41-410-069-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:11:55 UTC
Remove Variable Stator Vane Actuator (VSVA) for Shop Maintenance (Cleaning)
1. Reason for the Job
Refer to the MPD TASK: 753241-I1
REMOVE VARIABLE STATOR VANE ACTUATOR (VSVA) FOR SHOP MAINTENANCE (CLEANING)
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 75-32-41-000-010-A | Removal of the Variable Stator Vane (VSV) Actuator |
| TASK 75-32-41-400-010-A | Installation of the Variable Stator Vane (VSV) Actuator |
| TASK 75-32-41-400-010-A-01 | Installation of the Variable Stator Vane (VSV) Actuator (SBE 75-0122, Type G4000VSVA Series) |
Subtask 75-32-41-010-072-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. ProcedureSubtask 75-32-41-920-050-A ** ON A/C NOT FOR ALL
A. Replace the VSVA
(1) Remove the VSVA (Ref. AMM TASK 75-32-41-000-010).
(2) Send the VSVA to the shop for cleaning.
(3) Install a new or clean VSVA (Ref. AMM TASK 75-32-41-400-010).
5. Close-up(1) Remove the VSVA (Ref. AMM TASK 75-32-41-000-010).
(2) Send the VSVA to the shop for cleaning.
(3) Install a new or clean VSVA (Ref. AMM TASK 75-32-41-400-010).
Subtask 75-32-41-410-069-A ** ON A/C NOT FOR ALL
A. Not Applicable